GC Column Cross-Reference: Columns by Phase
Fused Silica Columns
Restek |
Phase Composition |
USP Nomenclature |
Agilent |
Varian/ Chrompack |
SGE |
Phenomenex |
Machery-Nagel |
Supelco |
100% dimethyl polysiloxane |
G1, G2, G38 |
HP-1, DB-1 |
CP Sil 5 CB |
BP-1 |
ZB-1 |
Optima-1 |
SPB-1 |
|
100% dimethyl polysiloxane (low bleed) |
HP-1ms UI, DB-1ms UI, HP-1, HP-1ms, DB-1, DB-1ms, Ultra-1 |
VF-1ms, CP-Sil 5, CP Sil 5 CB Low Bleed/MS |
BP-1 |
ZB-1, ZB-1ms |
Optima-1, Optima-1ms, Optima-1ms Accent |
SPB-1, Equity-1 |
||
100% dimethyl polysiloxane |
DB-1HT |
VF-1HT |
ZB-1HT |
|||||
5% diphenyl, 95% dimethyl polysiloxane |
G27, G36 |
HP-5, DB-5 |
CP Sil 8 CB |
BP-5 |
ZB-5 |
Optima-5 |
SPB-5 |
|
5% diphenyl, 95% dimethyl polysiloxane (low bleed) |
G27, G36 |
HP-5ms UI, HP-5, HP-5ms, DB-5, Ultra-2 |
CP-Sil 8, CP Sil 8 CB |
BP-5 |
ZB-5, ZB-5ms |
Optima-5, Optima-5ms |
SPB-5, Equity-5 |
|
5% phenyl, 95% dimethyl polysiloxane |
DB-5ms UI, DB-5ms |
VF-5ms, CP-Sil 8 CB Low Bleed/MS |
BPX-5 |
ZB-5MS |
Optima-5ms Accent |
SLB-5ms |
||
5% diphenyl, 95% dimethyl polysiloxane |
DB-5HT |
VF-5HT |
ZB-5HT |
|||||
arylene/ methyl modified polysiloxane |
DB-XLB |
VF-XMS |
MR1 |
Optima-XLB |
||||
20% diphenyl, 80% dimethyl polysiloxane |
G28, G32 |
SPB-20 |
||||||
35% diphenyl, 65% dimethyl polysiloxane |
G42 |
HP-35, DB-35 |
BPX-35, BPX-608 |
ZB-35 |
SPB-35, SPB-608 |
|||
35% phenyl, 65% dimethyl polysiloxane |
DB-35ms |
VF-35ms |
BP-35 |
MR2 |
Optima-35ms |
|||
50% phenyl, 50% methyl polysiloxane |
G3 |
HP-50 |
AT-50 |
Optima-17 |
SPB-50 |
|||
50% diphenyl, 50% dimethyl polysiloxane |
HP-17, DB-17, DB-608, HP-50+ |
CP-Sil 24 CB |
ZB-50 |
Optima-17 |
||||
50% phenyl, 50% dimethyl polysiloxane |
DB-17ms, HP-17, DB-17 |
VF-17ms, CP-Sil 24 CB |
BPX-50 |
ZB-50 |
Optima-17ms |
|||
65% diphenyl, 35% dimethyl polysiloxane |
G17 |
|||||||
6% cyanopropylphenyl, 94% dimethyl polysiloxane |
G43 |
HP-624, DB-624 |
VF-624ms |
BP-624 |
ZB-624 |
Optima-624 |
||
6% cyanopropyl phenyl, 94% dimethyl polysiloxane |
G43 |
HP-1301, HP-624, DB-1301, DB-624 |
CP-1301, VF-1301ms, VF-624ms |
BP-624 |
ZB-624 |
Optima-1301, Optima-624 |
SPB-1301 |
|
14% cyanopropyl phenyl, 86% dimethyl polysiloxane |
G46 |
HP-1701, PAS-1701, DB-1701 |
CP Sil 19 CB, VF-1701ms |
BP-10 |
ZB-1701, ZB-1701P |
Optima-1701 |
SPB-1701 |
|
trifluoropropyl methyl polysiloxane |
G6 |
DB-210, DB-200 |
VF-200ms |
Optima-210 |
||||
trifluoropropyl methyl polysiloxane (low bleed) |
VF-200ms |
|||||||
50% cyanopropyl, 50% phenylmethyl polysiloxane |
G7, G19 |
HP-225, DB-225 |
CP Sil 43 CB |
BP-225 |
Optima-225 |
SPB-225 |
||
modified polysiloxane (unique phase) |
Unique Column |
|||||||
90% biscyanopropyl, 10% cyanopropyl phenyl polysiloxane |
G48 |
BPX-70 |
SP-2330, SP-2331, SP-2380 |
|||||
bicyanopropyl polysiloxane |
HP-88 |
CP Sil 88 |
SP-2560 |
|||||
polyethylene glycol |
G14, G15, G16, G20, G39 |
HP-Wax, DB-Wax |
CP Wax 52 CB |
BP-20 |
ZB-Wax |
Optima Wax |
||
polyethylene glycol |
G14, G15, G16, G20, G39 |
Innowax |
CP Wax 52 CB, VF-WAX MS |
ZB-Wax Plus |
Supelcowax-10 |
|||
PLOT Columns
Restek |
Porous Layer |
Agilent |
Varian/ Chrompack |
SGE |
Phenomenex |
Machery-Nagel |
Supelco |
Aluminum oxide |
GS-Alumina, HP PLOT S |
CP-AL203/Na2SO4 |
AluminaSulfate-PLOT |
||||
Aluminum oxide |
GS-Alumina/KCl, HP PLOT Al203/KCl |
CP-AL203/KCl |
AluminaChloride-PLOT |
||||
Aluminum oxide |
Unique Column |
||||||
Molecular sieve 5A |
GS-Msieve, HP PLOT Molsieve |
CP-Molsieve 5A |
Molsieve 5A |
||||
DVB porous polymer |
CP-PoraPLOT Q, CP-PoraBond Q |
Supel-Q-PLOT |
|||||
Intermediate polarity porous polymer |
GS-Q |
||||||
DVB 4-vinylpyridine polymer |
CP-PoraPLOT S |
||||||
DVB ethylene glycol/dimethylacrylate polymer |
HP-PLOT U |
CP-PoraPLOT U, CP-PoraBond U |
|||||