delim
delim
delim
Metal (MXT) Capillary

Metal (MXT) Capillary

Products

MXT®-1HT SimDist Column (Siltek® treated stainless steel)

(nonpolar phases)

  • Stable up to 450 °C—lowest bleed for longest column lifetime.
  • Reliably meet all ASTM D6352, D7169, and D7500 specifications.
  • 100% dimethyl polysiloxane phase allows easy comparisons to historical data.

View Product Information

MXT®-Biodiesel TG Columns (Siltek® treated stainless steel)

  • Fast analysis times and sharp mono-, di-, and triglyceride peaks.
  • Stable at 430 °C for reliable, consistent performance.
  • Includes factory-coupled retention gap.

View Product Information

MXT®-Alumina BOND/Na2SO4 Columns (Siltek®-treated stainless steel PLOT)

Advantages of metal MXT® PLOT columns include:
  • Can be made in small coil diameters—perfect for tight spaces.
  • Rugged material withstands rough handling and shock.
  • Designed for robust performance in process GCs and field instruments.
  • Available in 3.5″-coil diameter or 7″-diameter, 11-pin cage.

View Product Information

MXT®-Alumina BOND/MAPD Columns (Siltek®-treated stainless steel PLOT)

  • Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene.
  • Stable response factors make this column ideal for process-type applications where recalibration must be minimized.
  • High loadability reduces peak tailing and improves separations.
  • Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) hydrocarbons and accelerated column regeneration following exposure to water.
  • Metal Siltek®-treated tubing is incredibly durable, allowing MXT® columns to be tightly coiled without breaking for use in smaller GC ovens.
    MXT®-Alumina BOND/MAPD PLOT columns are made specifically for the analysis of petrochemicals and downstream products such as ethylene, propylene, butylenes, and butadiene!

    Also available in fused silica Rt®-Alumina columns!

    Literature: Analyze Trace Polar Hydrocarbons More Accurately and Reliably With New Alumina BOND/MAPD PLOT Columns (1.49 MB PDF)

View Product Information

MXT®-Q-BOND Columns (Siltek®-treated stainless steel PLOT)

Advantages of metal MXT® PLOT columns include:
  • Can be made in small coil diameters—perfect for tight spaces.
  • Rugged material withstands rough handling and shock.
  • Designed for robust performance in process GCs and field instruments.
  • Available in 3.5″-coil diameter or 7″-diameter, 11-pin cage.

View Product Information

MXT®-S-BOND Columns (Siltek®-treated stainless steel PLOT)

Advantages of metal MXT® PLOT columns include:
  • Can be made in small coil diameters—perfect for tight spaces.
  • Rugged material withstands rough handling and shock.
  • Designed for robust performance in process GCs and field instruments.
  • Available in 3.5″-coil diameter or 7″-diameter, 11-pin cage.

View Product Information

MXT®-Msieve 5A Columns (Siltek®-treated stainless steel PLOT)

Advantages of metal MXT® PLOT columns include:
  • Can be made in small coil diameters—perfect for tight spaces.
  • Rugged material withstands rough handling and shock.
  • Designed for robust performance in process GCs and field instruments.
  • Available in 3.5″-coil diameter or 7″-diameter, 11-pin cage.

View Product Information

MXT®-624 Columns (Siltek® treated stainless steel)

(low to midpolarity phase; Crossbond® 6% cyanopropylphenyl/94% dimethyl polysiloxane)

  • Application-specific columns for volatile organic pollutants. Recommended in US EPA methods for volatile organic pollutants.
  • Temperature range: -20 °C to 280 °C.
  • Equivalent to USP G43 phase.

View Product Information

MXT®-502.2 Columns (Siltek® treated stainless steel)

(proprietary Crossbond® diphenyl/dimethyl polysiloxane phase)

  • Application-specific columns with unique selectivity for volatile organic pollutants, cited in US EPA Method 502.2 and in many gasoline range organics (GRO) methods for monitoring underground storage tanks. Excellent separation of trihalomethanes; ideal polarity for light hydrocarbons and aromatics.
  • Temperature range: -20 °C to 320 °C.

View Product Information

MXT®-WAX Columns (Siltek® treated stainless steel)

(polar phase; Crossbond® Carbowax® polyethylene glycol—provides oxidation resistance)

  • General purpose columns for FAMEs, flavor compounds, essential oils, amines, solvents, xylene isomers, and US EPA Method 603 (acrolein/acrylonitrile).
  • Resistant to oxidative damage.
  • Temperature range: 40 °C to 260 °C.
  • Equivalent to USP G14, G15, G16, G20, and G39 phases.

View Product Information

MXT®-65TG Columns (Siltek® treated stainless steel)

(high polarity phase; Crossbond® 65% diphenyl/35% dimethyl polysiloxane)

  • Application-specific columns, specially tested for triglycerides.
  • Stable to 370 °C.

View Product Information

MXT®-65 Columns (Siltek® treated stainless steel)

(mid to high polarity phase; Crossbond® 65% diphenyl/35% dimethyl polysiloxane)

  • General purpose columns for phenols and fatty acids.
  • Temperature range: 50 °C to 300 °C.
  • Equivalent to USP G17 phase.

View Product Information

MXT®-200 Columns (Siltek® treated stainless steel)

(midpolarity phase; Crossbond® trifluoropropylmethyl polysiloxane)

  • General purpose columns for solvents, Freon® fluorocarbons, alcohols, ketones, silanes, and glycols. Excellent confirmation column with an Rtx®-5 column, for phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides.
  • Temperature range: -20 °C to 400 °C.
  • Equivalent to USP G6 phase.

View Product Information

MXT®-50 Columns (Siltek® treated stainless steel)

(midpolarity phase; Crossbond® 100% methylphenyl polysiloxane)

  • General purpose columns for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, and sterols.
  • Temperature range: 0 °C to 300 °C.
  • Equivalent to USP G3 phase.

View Product Information

MXT®-35 Columns (Siltek® treated stainless steel)

(midpolarity phase; Crossbond® 35% diphenyl/65% dimethyl polysiloxane)

  • General purpose columns for organochlorine pesticides, PCB congeners (e.g. Aroclor mixes), herbicides, pharmaceuticals, sterols, rosin acids, and phthalate esters.
  • Temperature range: 0 °C to 340 °C.
  • Equivalent to USP G42 phase.

View Product Information

MXT®-1701 Columns (Siltek® treated stainless steel)

(midpolarity phase; Crossbond® 14% cyanopropylphenyl/86% dimethyl polysiloxane)

  • General purpose columns for alcohols, oxygenates, PCB congeners (e.g. Aroclor mixes), and pesticides.
  • Temperature range: -20 °C to 280 °C.
  • Equivalent to USP G46 phase.

View Product Information

MXT®-1301 Columns (Siltek® treated stainless steel)

(low to midpolarity phase; Crossbond® 6% cyanopropylphenyl/94% dimethyl polysiloxane)

  • General purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds.
  • Temperature range: -20 °C to 280 °C.
  • Equivalent to USP G43 phase.

View Product Information

MXT®-20 Columns (Siltek® treated stainless steel)

(low to midpolarity phase; Crossbond® 20% diphenyl/80% dimethyl polysiloxane)

  • General purpose columns for volatile compounds, flavor compounds, and alcoholic beverages.
  • Temperature range: -20 °C to 340 °C.
  • Equivalent to USP G28, G32 phases.

View Product Information

MXT®-Volatiles Columns (Siltek® treated stainless steel)

(proprietary Crossbond® diphenyl/dimethyl polysiloxane phase)

  • Application-specific columns for volatile organic pollutants.
  • Temperature range: -20 °C to 320 °C.

View Product Information

MXT®-5 Columns (Siltek® treated stainless steel)

(low polarity phase; Crossbond® 5% diphenyl/95% dimethyl polysiloxane)

  • General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g. Aroclor mixes), essential oils, and semivolatiles.
  • Temperature range: -60 °C to 430 °C.
  • Equivalent to USP G27, G36 phases.

View Product Information

MXT®-2887 Column (Siltek® treated stainless steel)

(nonpolar phase; Crossbond® 100% dimethyl polysiloxane—for simulated distillation)

  • Application-specific columns for simulated distillation.
  • Stable to 400 °C.

View Product Information

MXT®-500 SimDist Column (Siltek® treated stainless steel)

(nonpolar phase)

  • Application-specific columns in unbreakable Siltek® treated stainless steel tubing meet all resolution criteria for high temperature simulated distillation (e.g., ASTM Method D2887 Extended).
  • MXT®-1HT SimDist and MXT®-1 SimDist phases offer true methyl silicone polarity; MXT®-500 SimDist phase is a carborane siloxane polymer.
  • Stable to 430°C.

View Product Information

MXT®-1 Columns (Siltek® treated stainless steel)

(nonpolar phase; Crossbond® 100% dimethyl polysiloxane)

  • General purpose columns for solvent impurities, PCB congeners (e.g. Aroclor mixes), simulated distillation, drugs of abuse, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, and oxygenates.
  • Temperature range: -60 °C to 430 °C.
  • Equivalent to USP G1, G2, G38 phases.

View Product Information

MXT®-1 SimDist Column (Siltek® treated stainless steel)

(nonpolar phase)

  • Application-specific columns in unbreakable Siltek® treated stainless steel tubing meet all resolution criteria for high temperature simulated distillation (e.g., ASTM Method D2887 Extended).
  • MXT®-1HT SimDist and MXT®-1 SimDist phases offer true methyl silicone polarity; MXT®-500 SimDist phase is a carborane siloxane polymer.
  • Stable to 430 °C.

View Product Information

Hydroguard® Treated MXT® Guard/Retention Gap Columns/Transfer Lines (passivated stainless steel)

  • Extend analytical column lifetime by preventing degradation by harsh “steam-cleaning” water injections.
  • Maximum temperature: 430 °C.

View Product Information

Intermediate-Polarity Deactivated MXT® Guard/Retention Gap Columns/Transfer Lines (passivated stainless steel)

  • Useful for a wide range of applications.
  • Compatible with most common solvents.
  • Maximum temperature: 350 °C

View Product Information