Packed & Micropacked
| Products |
|---|
D3606 Application Column (packed, 2 column set)
View Product Information |
Rt®-XLSulfur Columns (packed)
View Product Information |
Porous Polymer Columns (packed)
View Product Information |
CarboBlack Columns (packed)(On CarboBlack C)
View Product Information |
CarboBlack Columns (packed)(On CarboBlack B)
View Product Information |
CarboBlack Columns (packed)5% Krytox (Nickel 200 tubing)
View Product Information |
Molecular Sieve Packed ColumnsMolecular sieve packed columns easily separate permanent gases at above-ambient temperatures. Restek's R&D chemists have developed a process for preparing molecular sieve packings, which result in excellent batch-to-batch reproducibility. In addition, our molecular sieves are preactivated and ready to use. Each column comes with metal end-fittings to prevent water or carbon dioxide from adsorbing into the packing during shipment. View Product Information |
Chromosorb® Diatomaceous Earth SupportsRestek offers the full line of Chromosorb® solid supports that are specially sieved to remove fines and ensure tight particle distribution. Choosing the appropriate support will depend on your application. Need assistance? Call Technical Service at 800-356-1688 or 814-353-1300, ext. 4, or contact your Restek representative for more information. View Product Information |
Micropacked GC Columns (0.53mm ID)
View Product Information |
2abc Refinery Gas Column Set (packed)This 3-column set is finely tuned to resolve light hydrocarbons. When used in the proper valving system, it will elute C5+ hydrocarbons ahead of C1 through C4 hydrocarbons. View Product Information |
OPN on Res-Sil® C Column (packed)This column separates the light hydrocarbons, and baseline resolves cis-2-butene from 1,3-butadiene. View Product Information |
n-Octane on Res-Sil® C Column (packed)This packed column has unique selectivity for resolving unsaturated light hydrocarbons. View Product Information |
Packed Column Inlet Adaptor Kitfor 1/4″ Injection Ports
View Product Information |
Rt®-608Pkd Columns (packed)Optimized for pesticide analysis by US EPA Method 608.Pesticide analysis remains the largest environmental application for packed columns. Currently, mixed phase packed columns do not offer complete resolution of chlorinated pesticides, and require long analysis times (nearly 40 minutes). Restek has developed a special packing material that exceeds EPA Method 608 resolution requirements while delivering a faster analysis time than any other pesticide phase packed column available. Inert SilcoSmooth® tubing and highly inert Silcoport® support make it possible to analyze chlorinated pesticides at levels below 50pg—performance that is nearly impossible with older packed column technology. The computer-modeled phase resolves all 18 peaks in US EPA Method 608 in less than 12 minutes—one-third the time previously required! Compare the performances of conventional 1.5% SP-2250/1.95% SP-2401 pesticide packing and innovative Rt®-608Pkd packing, and you’ll stop wasting time with old technology. View Product Information |
Micropacked Inlet Conversion Kits
View Product Information |
Rt®-XLSulfur Columns (micropacked)**
View Product Information |
Res-Sil® Packing Materials
View Product Information |
Micropacked GC Columns
View Product Information |
CarboBlack Packing Materials
View Product Information |