delim
Inlet Liners

Inlet Liners

Inlet Liner Packing Tool

  • Position wool reproducibly every time.
  • Accurate to a specific, measured depth.
  • Can be used with all manufacturer's liners.

Inlet Liner Removal Tool

  • Easily remove liner from injector—no more burned fingers.
  • Made from high-temperature silicone.
  • Won’t chip or crack the liner.

The Claw and The Claw Holder Kit

  • Easily removes hot liners from injection ports.
  • 4 mL vials (not included) can be replaced when dirty.

CarboFrit® Puller/Inserter Tool

  • Hook end for removing CarboFrit® inserts.
  • Bent end (90°) for inserting CarboFrit® inserts.

Mini Wool Puller/Inserter

Insert and remove wool plugs easily. Order a spare pack so you’ll always have one available.

Base-Deactivated Wool

Ideal for amines and other basic compounds.

Deactivated Wool

  • More inert than our traditional fused silica wool.
  • Use to vaporize a sample in a liner prior to introduction into a capillary column.

Deactivated Borosilicate Glass Wool

More flexible than fused silica wool.

Technical Articles

Environmental

New Wool Ensures More Accurate Semivolatiles Analyses

New Semivolatiles Wool, pre-packed in Restek liners, is designed specifically for semivolatiles analysis and result in more accurate results at lower levels, compared to similar products.

Environmental

Choosing a Liner for Semivolatiles Analyses

Liner choice is a critical decision in semivolatiles analysis. Liners containing wool packing are recommended to minimize molecular weight discrimination. Attributes of different types of liners, including the Drilled Uniliner®, are discussed.

Clinical, Forensic & Toxicology

GC Inlet Liner Deactivations for Basic Drug Analysis

Basic drugs can interact with active sites on the surface of the inlet liner, reducing responses. The combination of a base-deactivated liner and a base-deactivated Rtx®-5Amine column ensures the greatest responses in analyses for these compounds.

Environmental

PTV On-Column Liner Gives You Two Inlets in One

Programmable temperature vaporization inlets are versatile, yet normally do not accommodate on-column injection. Now, using a PTV On-Column liner, the capabilities of PTV can be expanded to include true on-column injections.

General Interest

Warm Up Before You Run Why conditioning your inlet parts after maintenance is good practice

Background noise in a gas chromatography system can be eliminated by conditioning the system prior to sample analysis. In this article, we discuss warm-up procedures and use liners and liner installation to demonstrate the importance of conditioning the system to remove background peaks. Investing a little time in warming-up the system pays big dividends by preventing costly coelutions and avoidable reanalyses.

PDF Document

Sky™ Inlet Liners: True Blue Performance

Exceptionally inert, Sky™ inlet liners improve trace level analysis for a wide range of compounds. These blue liners have a new deactivation that allows analysts to increase accuracy and precision, lower detection limits, and use wool with confidence. (PDF - 517kB)