share:
delim
Packed Column Information

Packed Column Information

Table I:  For specific applications, we recommend using these optimized columns for better method performance. Click on the column name for product specifications and easy online ordering.

Application

Column

Feature

Benefit

ASTM Method D3606

D3606 Application Column Set
Column 1: 6' (1.8 m), 1/8" OD, 2.0 mm ID, Rtx-1; Column 2: 16' (4.9 m), 1/8" OD, 2.0 mm ID, proprietary packing material

Excellent separation of ethanol and benzene.

Reliably meets method requirements.

Refinery Gases

2abc Refinery Gas Column Set
Backflush Column

Optimized three-column set. (Backflush column sold separately.)

Elutes C5 hydrocarbons before C1-C4 hydrocarbons for optimized resolution.

Unsaturated Light Hydrocarbons

n-Octane on Res-Sil C Column

Unique selectivity for unsaturated hydrocarbons.

Excellent resolution of unsaturated light hydrocarbons gives increased data accuracy.

cis-2-Butene and 1,3-Butadiene

OPN on Res-Sil C Column

Optimized selectivity for cis-2-butene and 1,3-butadiene resolution.

Increased data accuracy.

Permanent Gases

ShinCarbon ST Columns
Packed / Micropacked

Optimized selectivity for permanent gas resolution without cryogenic cooling. Preconditioned.

Increases productivity.

Low-Level Sulfurs

Rt-XLSulfur Columns
Packed / Micropacked

Highly inert for ppbv levels of sulfur. Eliminates need for PTFE tubing.

Increased data accuracy for low-level sulfur analysis. Eliminates need for a special GC setup.



Table II:  Select the packed column configuration that fits your instrument from the options below and add the corresponding suffix to any standard part number.
(Note that small ID columns [1/16” or less] do not require a suffix.)

Suffix

Configuration

-800

General

-810

Agilent 5880, 5890, 5987, 6890, 7890

-811

Agilent 6850

-820

Scion (Bruker 430, 450; Varian 3700, Vista Series FID)

-821

Bruker 430, 450, Varian 3800

-830

PE 900-3920; Sigma 1,2,3

-840

PE Auto-System 8300, 8400, 8700; Clarus 500

-841

PE Auto-System XL

-850

Shimadzu 14A, 2014

-851

Shimadzu 8A

-852

Shimadzu 9A

-853

Shimadzu 17A, 2010

-854

Shimadzu Mini 2

-860

Thermo TRACE 2000

-865

Carlo Erba

-870

Tremetrics/Tracor

-874

HNU 310, 311

-875

Analytical Controls

-880

Carle 40030

-881

Hitachi 263

-885

Pye Unicam 4500

-890

Gow Mac 590

-891

Gow Mac 550

-892

Gow Mac 750

-893

Gow Mac 816

-894

Gow Mac 580

-895

SRI 8610C

-895R

SRI 8610C Dual GC right side

-895L

SRI 8610C Dual GC left side

-896

SRI 9300



Table III:  Complete your column with one of our fitting kits.

Option*

Description

Kit 1S

Fitting Kit: 1/4" Brass Nuts, 1/4" TO 1/8" VG Reducing Ferrules

Kit 2S

Fitting Kit: 1/4" Brass Nuts, 1/4" TO 3/16" VG Reducing Ferrules

Kit A

Fitting Kit: 1/8" Brass Nuts, 1/8" VG Ferrules

Kit B

Fitting Kit: 1/8" Brass Nuts, 1/8" Brass Front & Back Ferrules

Kit C

Fitting Kit: 1/8" SS Nuts, 1/8" SS Front & Back Ferrules

Kit D

Fitting Kit: 1/8" SS Nuts, 1/8" SS Ferrules

Kit E

Fitting Kit: 1/4" SS Nuts, 1/4" TO 1/8" VG Reducing Ferrules

Kit F

Fitting Kit: 1/4" SS Nuts, 1/4" TO 3/16" VG Reducing Ferrules

Kit V

Fitting Kit: 1/8" VCR; choose SS or Nickel

Preconditioning

Optional for each finished column

*Some options available at additional cost.