EPA Superfund Contract Lab Program (CLP)

Reference Standards: EPA Superfund Contract Lab Program (CLP)

Looking for a Specific Compound?

Enter an compound name, synonym, or CAS # below.

Products

CLP VOA CAL2000 MegaMix® Kit

Contains 1mL each of these mixtures.
30632: CLP VOA CAL2000 MegaMix
30216: vinyl acetate

View Product Information

CLP 04.1 B/N MegaMix® Kit

Contains 1mL each of these mixtures.
31903: CLP 04.1 B/N MegaMix, Revision 2
31902: CLP/SVOA Additions Mix

View Product Information

SOM01.1 SVOA MegaMix® Kit

Contains 1mL each of these mixtures.
31900: SOM01.1 SVOA MegaMix, Revised
31902: CLP/SVOA Additions Mix

View Product Information

SOM01.1 VOA DMC Kit

500 µg/mL. 1mL each of these mixtures.
30624: Non-Ketones
30625: Ketones

View Product Information

Pesticide Kit #3

Contains 1mL each of these mixtures.
32003: Pesticide Standard Mix A w/Surrogates
32004: Pesticide Standard Mix B w/Surrogates
32005: Toxaphene
32007: Aroclor 1221
32008: Aroclor 1232
32009: Aroclor 1242
32010: Aroclor 1248
32011: Aroclor 1254
32039: Aroclor 1016/1260

View Product Information

Pesticide Standard Mix B w/Surrogates (13 components)

Components of these products are at 16x the Contract Required Quantitation Level (CRQL) and can be used to prepare calibration mixes at 4x CRQL and at 1x CRQL by serial dilution.

View Product Information

Pesticide Standard Mix A w/Surrogates (11 components)

Components of these products are at 16x the Contract Required Quantitation Level (CRQL) and can be used to prepare calibration mixes at 4x CRQL and at 1x CRQL by serial dilution.

View Product Information

Revised GPC Calibration Mix (5 components)

Qualitative mixture useful for determining GPC dump/collect times. The compounds are dissolved in methylene chloride at the concentrations listed.

View Product Information

CLP GPC Calibration Mix (5 components)

Qualitative mixture useful for determining GPC dump/collect times. The compounds are dissolved in methylene chloride at the concentrations listed.

View Product Information

L/C B/N Lab Control Sample Kit

Contains 1mL each of these mixtures.
30310: L/C B/N Lab Control Sample Mix A
31211: L/C Aniline Mix B

View Product Information

Fortification Mix (7 components)

  • Complete—all 66 OLC03.2 compounds in four ampuls: MegaMix® reference mix, fortification mix, 3,3′-dichlorobenzidine, 4-chloroaniline.
  • Convenient single calibration—2- and 3-cresol isomers at 1/2 concentration of other MegaMix® mix components.
  • Fortification mix includes all 7 compounds requiring calibration at higher concentration.
  • Deuterated Monitoring Compound (DMC) Mix for quality control requirements.

View Product Information

OLC 03.2 SVOA Deuterated Monitoring Compounds (DMC) (16 components)

The EPA Contract Lab Program (CLP) Statement of Work (SOW) OLC03.2 is an analytical method for detection of low concentration volatile, semivolatile, and pesticide/Aroclor® organics in aqueous samples. For VOA and SVOA GC/MS analysis OLC03.2 introduces deuterated monitoring compounds (DMCs) as a sample-by-sample accuracy indicator.

View Product Information

Semivolatile Calibration Kit #3 (with benzidine)

Contains 1mL each of these mixtures.
31007: SV Calibration Mix #1 (anilines)
31008: SV Calibration Mix #2 (phenols)
31009: SV Calibration Mix #3 (base neutrals)
31010: SV Calibration Mix #4 (base neturals)
31011: SV Calibration Mix #5 (PAHs)
31013: SV Calibration Mix #7 (dichlorobenzenes)
31030: 605 Benzidines Calibration Mix (benzidine & 3,3′-dichlorobenzidine)

View Product Information

CLP Semivolatile Calibration Kit #2 (without pesticides)

Contains 1mL each of these mixtures.
31007: SV Calibration Mix #1 (anilines)
31008: SV Calibration Mix #2 (phenols)
31009: SV Calibration Mix #3 (base neutrals)
31010: SV Calibration Mix #4 (base neturals)
31011: SV Calibration Mix #5 (PAHs)
31013: SV Calibration Mix #7 (dichlorobenzenes)
31026: 3,3′-dichlorobenzidine

View Product Information

OLC 03.2 VOA MegaMix® (42 components)

  • MegaMix® reference mix includes all 50 analytes, ketones, and gases.
  • Convenient single calibration—m- and o-xylene isomers at 1/2 concentration of other MegaMix® mix components.
  • Deuterated Monitoring Compound (DMC) Mix for quality control requirements.

View Product Information

L/C VOA Lab Control Sample #2 (vinyl chloride)

We prepare the L/C VOA Lab Control Sample in two parts. Sample #1 contains all compounds except vinyl chloride, because this compound is extremely volatile and must be replaced frequently. Sample #2 contains vinyl chloride.

View Product Information

L/C VOA Lab Control Sample #1 (11 components)

We prepare the L/C VOA Lab Control Sample in two parts. Sample #1 contains all compounds except vinyl chloride, because this compound is extremely volatile and must be replaced frequently. Sample #2 contains vinyl chloride.

View Product Information

CLP VOA Calibration Kit #2

Contains 1mL each of these mixtures.
30006: VOA Calibration Mix #1 (ketones)
30010: VOA Calibration Mix #5 (gases)
30632: CLP VOA CAL2000 MegaMix
30216: vinyl acetate

View Product Information

CLP 04.1 VOA Kit #3

Contains 1mL each of these mixtures.
30006: VOA Calibration Mix #1 (ketones)
30042: 502.2 Calibration Mix #1 (gases)
30456: CLP 04.1 VOA CAL2000 MegaMix

View Product Information

B/N Matrix Spike Mix (6 components)

  • Highest concentrations commercially available.
  • Convenient 1mL, 5mL, and 10mL package sizes.
  • Reduces laboratory cost per sample extract.

View Product Information

Acid Surrogate Mix (4/89 SOW) (3 components)

  • Highest concentrations commercially available.
  • Convenient 1mL, 5mL, and 10mL package sizes.
  • Reduces laboratory cost per sample extract.

View Product Information

B/N Surrogate Mix (4/89 SOW) (3 components)

  • High purity for consistent results.
  • Free quality assurance data package available on-line.
  • Highest concentrations commercially available.
  • Convenient 1mL, 5mL and 10mL package sizes reduces cost per sample extract.

View Product Information

SV Internal Standard Mix (6 components)

  • High purity for consistent results.
  • Free quality assurance data package available on-line.
  • Highest concentrations commercially available.

View Product Information

Organochlorine Pesticide System Evaluation Mix (2 components)

  • Designed for daily assessment of system performance.
  • Reveals active sites in the injection port and/or GC column.
  • Prepared in MTBE—low expansion volume helps minimize backflash.

View Product Information