Column Connectors

Products

Universal “Y” Press-Tight® Connectors

An alternative method of performing dual-column confirmational analyses!

  • Split sample flow onto two columns—perform confirmation analysis with a single injection.
  • Split a single column flow to two detectors.

View Product Information

Universal Press-Tight® Connectors

  • Connect a guard column to an analytical column.
  • Repair a broken column.
  • Connect a column outlet to a transfer line.

View Product Information

Universal Angled “Y” Press-Tight® Connectors

  • Perform confirmation analysis with a single injection.
  • Made from inert fused silica.
  • Inlet and outlet ends conform to the column curvature—alleviates column-end connection strain.

View Product Information

MXT® “Y”-Union Connector Kits

for Fused Silica Columns

  • Low-dead-volume, leak-tight connection.
  • Reusable.
  • Siltek® treatment ensures maximum inertness.
  • Ideal for connecting a guard column or transfer line to an analytical column.
  • Use to oven temperatures of 360 °C.
  • Available in union and “Y” configurations.
  • Can also be used for fused silica to metal connections.

View Product Information

Zero-Dead-Volume Valco® Internal Union

Ends of tubing seat squarely at bottoms of fitting details. 300 series stainless steel. For 1/16″ OD tubing. Stainless steel ferrules included.

View Product Information

Vu2 Union® Connectors

  • Connect a guard column to an analytical column.
  • Connect a column to a transfer line.
  • Connect two columns in series.
  • Repair a broken column.
  • Fit both Restek cage designs.

View Product Information

SeCure® “Y” Connector Kits

  • Connect two analytical columns to a transfer line or guard column.
  • Use standard “Y” Press-Tight® connectors and 1/16″ graphite ferrules.
  • Reliable seal integrity, will not unexpectedly disconnect during temperature-programmed analyses.
  • Open design allows visual confirmation of the seal for added confidence in the connection.
  • Fit both Restek cage designs.

View Product Information

MXT® Low-Dead-Volume Connector Kits

for Metal Columns

  • Connect a guard column/transfer line to an MXT® stainless steel column.
  • Low thermal mass tracks rapid oven temperature programming.
  • Stainless steel ferrules and nuts.
  • Available in “Y” and union configurations.
  • Siltek® treatment ensures ultimate inertness.

    Each kit contains the MXT® union, two 1/32-inch ferrules and nuts.

View Product Information

MXT®-Union Connector Kits

for Fused Silica Columns

  • Low-dead-volume, leak-tight connection.
  • Reusable.
  • Siltek® treatment ensures maximum inertness.
  • Ideal for connecting a guard column or transfer line to an analytical column.
  • Use to oven temperatures of 360 °C.
  • Available in union and “Y” configurations.
  • Can also be used for fused silica to metal connections.

View Product Information

Vacuum Vu-Union® Connector for GC/MS Applications

  • Connects analytical column to MS transfer line.
  • Use under vacuum conditions.
  • Use only with Vu-Union® Vespel®/graphite ferrules (order ferrules separately).
  • Includes metal housing body, one deactivated tapered glass insert, and Vu-Union® Helping Hand.
  • Fits column ODs from 0.33–0.74 mm (Restek 0.1 mm–0.53 mm ID).

View Product Information

Zero-Dead-Volume Valco® Internal Cross

Connect four lines. 300 series stainless steel; stainless steel ferrules included. For 1/16″ OD tubing.

View Product Information

Zero-Dead-Volume Valco® Internal Tee

Connect three lines. 300 series stainless steel; stainless steel ferrules included. For 1/16″ OD tubing.

View Product Information

Zero-Dead-Volume Valco® Internal Reducing Union

Connect two sizes of tubing, using zero-dead-volume fittings on each end. For 1/8″ to 1/16″ OD tubing. Stainless steel ferrules included.

View Product Information

MXT® Low-Dead-Volume “Y” Connector Kits

for Metal Columns

Connect two MXT® columns to one inlet or one MXT® column to two detectors.

Each kit contains the MXT® union, three 1/32-inch ferrules and nuts.

View Product Information

Universal Angled Press-Tight® Connectors

  • Ideal for connecting a guard column to an analytical column.
  • Made from inert fused silica.
  • Angle approximates the curvature of a capillary column, reduces strain on column-end connections.

View Product Information

Polyimide Resin

Securely connects a Press-Tight® connector to a fused silica column.

View Product Information

Nuts & Ferrules (1/16-Inch Stainless Steel)

for Valco® Connectors

Restek offers a selected line of Valco® fittings for connecting fused silica or 1/16- or 1/8-inch metal tubing. Valco® fittings have been designed for the specific demands of instrumentation and manufactured with the tight tolerances and premium quality that analysts require. If you don’t see the Valco® fitting you need, please request special ordering information.

View Product Information

1/16-Inch Valco® Adaptor Ferrules

Fused silica adaptor ferrules are Valcon polyimide, a unique graphite-reinforced composite, specially prepared to maximize mechanical stability at temperatures to 350°C. The determining factor for selecting adaptor ferrule size is the fused silica tubing OD.

View Product Information

1/32-Inch Valco® Adaptor Ferrules (Valcon Polyimide)

Fused silica adaptor ferrules are Valcon polyimide, a unique graphite-reinforced composite, specially prepared to maximize mechanical stability at temperatures to 350 °C. The determining factor for selecting adaptor ferrule size is the fused silica tubing OD.

View Product Information

1/4-Inch–3/16-Inch Open-End Wrenches

High-quality miniature wrenches to use with MXT® low-dead-volume connectors.

View Product Information

Gerstel GRAPHPACK® 3D/2 Connectors

GRAPHPACK® technology provides a complete system that quickly and reliably makes a leak-tight, low-dead-volume connection. The central component is a metal-jacketed graphite ferrule—the ideal seal for GC applications.

View Product Information

0.15/0.45mm Vu-Union® Connector

  • Fits any manufacturer’s column with an OD from 0.15–0.45mm.
  • Includes metal housing body, one deactivated tapered glass insert, and Vu-Union® Helping Hand.
  • Use only with Vu-Union® graphite ferrules—order ferrules separately.

View Product Information