Detector Supplies
| Products |
|---|
ETP Electron Multipliersfor Mass Spectrometry
View Product Information |
MSD Source Nut
View Product Information |
EZ No-Vent® GC Column-Mass Spectrometer Connectorfor Agilent GCs with 5971/5972, 5973, or 5975 GC/MS
View Product Information |
Inland 45 Pump OilRecommended for most mass spectrometers.
View Product Information |
MSD Conversion Fitting
View Product Information |
EZ No-Vent® GC Column-Mass Spectrometer Connectorfor Shimadzu QP 2010 & QP 2010 Plus
View Product Information |
GC/MS Cleaning KitPoor sensitivity, loss of sensitivity at high masses, or high multiplier gain during an auto tune are all indicators that your mass spectrometer source may need to be cleaned. Restek has assembled all of the necessary components for cleaning and polishing your ion source. View Product Information |
Gold Tip Transfer Line
View Product Information |
EZ No-Vent® GC Column-Mass Spectrometer Connectorfor Thermo Scientific Focus DSQ GC Mass Spectrometers
View Product Information |
EZ No-Vent® GC Column-Mass Spectrometer Connectorfor Varian Saturn 2000 Series Mass Spectrometers
View Product Information |
Heater/Sensor Assemblyfor Agilent 6850/6890/7890 GCs
View Product Information |
FID Maintenance Kitsfor Agilent GCs
View Product Information |
ETP Electron Multipliers for Mass Spectrometryfor Thermo Finnigan TRACE DSQ, DSQII, and Polaris Q GC/MS
View Product Information |
FID Jetfor Thermo Scientific TRACE and Focus GCs |
Transfer Line Reducing Kitfor Thermo Scientific TRACE and Focus DSQ Mass Spectrometers |
FID Collector Housing Kitsfor Agilent GCs
View Product Information |
FID Jet Removal Toolfor Agilent 5890/6890/6850/7890 FIDs
View Product Information |
Spanner Wrenchfor Agilent 5890/6890/6850/7890 FID Collector Assemblies
View Product Information |
FID Capillary Column Adaptorfor PerkinElmer Auto SYS XL
View Product Information |
FID Replacement Partsfor PerkinElmer Auto SYS XL and Clarus 500
View Product Information |
FID Base Weldmentfor Agilent GCs
View Product Information |
FID Collector Mountfor Agilent GCs
View Product Information |
Ion Source Cleaning PowderUse this aluminium oxide powder to clean surfaces that contact the sample or ion beam when you encounter poor sensitivity and inadequate abundances at high masses. View Product Information |
Rough Pump Oil #19for MSD Pumps, Oil Vacuum Pump
View Product Information |
Heater Cartridge & Platinum Resistance Thermometer (PRT) Sensorfor Agilent 5890 GCs
View Product Information |
Capillary Installation Gaugefor Agilent 5973/5975 MS
View Product Information |
FID Collector Assembly Kitfor Agilent 6890/6850/7890 GCs
View Product Information |
Cleaned PTFE Transfer Lines for ELCDsWe stringently clean our ELCD PTFE transfer lines with an HCl solution to remove any contaminants, then rinse with methanol. Convenient 6.5-inch precut pieces directly interface the nickel reaction tube and conductivity cell in Tracor, Tremetrics, O.I., and many other ELCDs. View Product Information |
Photoionization (PID) LampsModel 108-10.0/10.6 offers both 10.0 and 10.6 eV potential, has a 0.781″ base diameter, and is used in Tracor, OI, and Baseline instruments. Model 103 has a 1.375″ base and is used in HNU and SRI detectors. Model 108-BTEX lamp’s higher output makes it ideal for detection of BTEX compounds. View Product Information |
1/16-Inch Vespel®/Graphite Sealing RingReplacement Accesories for Hall 1000Installs onto the nickel reaction tube after the screw. Easily compresses on the reaction tube to provide a leak-tight seal and prevent detector oxidation. View Product Information |
ELCD Nickel Reaction Tube Nutfor Hall 1000High-quality stainless steel ELCD nut mounts nickel reaction tube into ELCD. View Product Information |
ELCD Nickel Reaction Tubesfor Hall 1000
View Product Information |
FID Gauge Packfor Agilent 5890 GCs
View Product Information |
ECD/FID Dual-Purpose Make-Up Gas Kitfor Agilent 5890 GCsKit includes: replacement fitting, 1/4″ nut, Vespel/graphite ferrule, 1/16″ nut, 0.4 mm ID graphite ferrule, Siltek treated guide View Product Information |
Packed Column FID Replacement Jetsfor Agilent 5890/6890/6850 GCs
View Product Information |
Capillary Dedicated FID Replacement Jetfor Agilent 6890/6850/7890 GCsAvailable in standard, high-temperature, or Siltek® treated high-performance versions. View Product Information |
Capillary Adaptable FID Replacement Jetfor Agilent 5890/6890/6850 GCs |
FID/NPD Capillary Adaptor Fittingfor Agilent 5890/6890/6850 GCs
View Product Information |
FID/NPD Adaptor Fitting
View Product Information |
Injector/Detector Plug Nuts
View Product Information |
FID Flow Measuring Adaptorfor Agilent 5890/6890/6850/7890 GCs
View Product Information |
FID Collector Assembly Kitfor Agilent 5890 GCs
View Product Information |
Stainless Steel Jet ReamersA great tool for cleaning detector jets or removing stuck ferrules from other small orifices. Serrated design is optimal for removing silica deposits and other contaminants. View Product Information |