Ferrules
| Products |
|---|
Capillary Ferrulesfor 1/16-Inch Compression-Type Fittings |
Compact Ferrules (Fit ≤ 0.28mm ID Fused Silica Columns)for Agilent GCs |
Compact Ferrules (Fit 0.32mm ID Fused Silica Columns)for Agilent GCs |
Standard Ferrulesfor 1/16-, 1/8-, and 1/4-Inch Fittings |
Blank Ferrulesfor 1/16-Inch Fittings
View Product Information |
Standard Ferrules (Fit 0.45/0.53mm ID Fused Silica Columns)for Agilent, PerkinElmer, & Varian GCs |
Compact Ferrules (Fit 0.45/0.53mm ID Fused Silica Columns)for Agilent GCs |
Standard Ferrules (Fit 0.32mm ID Fused Silica Columns)for Agilent, PerkinElmer, & Varian GCs |
Standard Ferrules (Fit ≤ 0.28mm ID Fused Silica Columns)for Agilent, PerkinElmer, & Varian GCs |
Ferrules for Micropacked ColumnsStandard—for 1/16″ Fittings |
Ferrulesfor EZ No-Vent® GC Column-MS Connectors |
Ferrules for Micropacked ColumnsCompact—for Agilent 5890/6890/6850/7890 GCs |
Ferrules for Micropacked ColumnsCapillary—for 1/16″ Compression-Type Fittings |
Ferrules (Fit 0.53mm ID MXT® Columns)for SRI & Buck Scientific GCs |
Ferrules (Fit 0.25/0.32mm ID MXT® Columns)for SRI & Buck Scientific GCs |
Ferrules (Fit 0.45/0.53mm ID Fused Silica Columns)for SRI & Buck Scientific GCs |
Ferrules (Fit 0.32mm ID Fused Silica Columns)for SRI & Buck Scientific GCs |
Ferrules (Fit 0.25/0.32mm ID Fused Silica Columns)for SRI & Buck Scientific GCs |
Ferrules (Fit 0.53mm ID MXT® Columns)for Shimadzu GCs |
Ferrules (Fit 0.25/0.32mm ID MXT® Columns)for Shimadzu GCs |
Ferrules (Fit 0.45/0.53mm ID Fused Silica Columns)for Shimadzu GCs |
Ferrules (Fit 0.32mm ID Fused Silica Columns)for Shimadzu GCs |
Ferrules (Fit ≤0.28mm ID Fused Silica Columns)for Shimadzu GCs |
Ferrules (Fit 0.45/0.53mm ID MXT® Columns)for Thermo Scientific GCs |
Ferrules (Fit 0.25/0.32mm ID MXT® Columns)for Thermo Scientific GCs |
Ferrules (Fit 0.45/0.53mm ID Fused Silica Columns)for Thermo Scientific GCs |
Ferrules (Fit 0.32mm ID Fused Silica Columns)for Thermo Scientific GCs |
Ferrules (Fit ≤0.28mm ID Fused Silica Columns)for Thermo Scientific GCs |
Standard Ferrules (Fit 0.53mm ID MXT® Columns)for Agilent, PerkinElmer, & Varian GCs |
Compact Ferrules (Fit 0.53mm ID MXT® Columns)for Agilent GCs |
Standard Ferrules (Fit 0.25/0.32mm ID MXT® Columns)for Agilent, PerkinElmer, & Varian GCs |
Compact Ferrules (Fit 0.25/0.32mm ID MXT® Columns)for Agilent GCs |
Standard Ferrules (Fit 0.28mm ID MXT® Columns)for Agilent, PerkinElmer, & Varian GCs |
Nut & Ferrule Set (Brass & Stainless Steel)Swagelok®Restek is pleased to offer one of the premier lines of fittings available for chromatographers in the market today. We can supply the entire line of Swagelok® fittings. Fittings are available in brass and stainless steel. Siltek®/Sulfinert® treated or Silcosteel®-CR treated fittings are also available. If you don't see the exact product you're looking for, please call us for a quote. View Product Information |
Front Ferrule (Brass & Stainless Steel)Swagelok®Restek is pleased to offer one of the premier lines of fittings available for chromatographers in the market today. We can supply the entire line of Swagelok® fittings. Fittings are available in brass and stainless steel. Siltek®/Sulfinert® treated or Silcosteel®-CR treated fittings are also available. If you don't see the exact product you're looking for, please call us for a quote. View Product Information |
Back Ferrule (Brass & Stainless Steel)Swagelok®Restek is pleased to offer one of the premier lines of fittings available for chromatographers in the market today. We can supply the entire line of Swagelok® fittings. Fittings are available in brass and stainless steel. Siltek®/Sulfinert® treated or Silcosteel®-CR treated fittings are also available. If you don't see the exact product you're looking for, please call us for a quote. View Product Information |
Nut & Ferrule Set (Brass & Stainless Steel)ParkerParker’s (A-Lok) fittings are ideal for installing new equipment, modifying existing instrumentation, or replacing worn connections. Fittings are available in brass and stainless steel. Siltek®/Sulfinert® treated or Silcosteel®-CR treated fittings are also available. If there is a particular Parker fitting that you are looking for and it is not listed here, please contact us to inquire about availability. View Product Information |
Front Ferrule (Brass & Stainless Steel)ParkerParker’s (A-Lok) fittings are ideal for installing new equipment, modifying existing instrumentation, or replacing worn connections. Fittings are available in brass and stainless steel. Siltek®/Sulfinert® treated or Silcosteel®-CR treated fittings are also available. If there is a particular Parker fitting that you are looking for and it is not listed here, please contact us to inquire about availability. View Product Information |
Back Ferrule (Brass & Stainless Steel)ParkerParker’s (A-Lok) fittings are ideal for installing new equipment, modifying existing instrumentation, or replacing worn connections. Fittings are available in brass and stainless steel. Siltek®/Sulfinert® treated or Silcosteel®-CR treated fittings are also available. If there is a particular Parker fitting that you are looking for and it is not listed here, please contact us to inquire about availability. View Product Information |
Alumaseal® Ferrules*
View Product Information |
Graphite Ferrulesfor SeCure® “Y” Connectors
View Product Information |
Graphite Ferrulesfor Vu2 Union® Connectors
View Product Information |
5 mm Ferrulesfor Shimadzu 17A GCs |
Teflon® Ferrules
View Product Information |
Nuts & Ferrules (1/16-Inch Stainless Steel)for Valco® ConnectorsRestek offers a selected line of Valco® fittings for connecting fused silica or 1/16- or 1/8-inch metal tubing. Valco® fittings have been designed for the specific demands of instrumentation and manufactured with the tight tolerances and premium quality that analysts require. If you don’t see the Valco® fitting you need, please request special ordering information. View Product Information |
1/16-Inch Valco® Adaptor FerrulesFused silica adaptor ferrules are Valcon polyimide, a unique graphite-reinforced composite, specially prepared to maximize mechanical stability at temperatures to 350°C. The determining factor for selecting adaptor ferrule size is the fused silica tubing OD. View Product Information |
Encapsulated Ferrulesfor 1/16-Inch Compression Fittings
View Product Information |
1/32-Inch Valco® Adaptor Ferrules (Valcon Polyimide)Fused silica adaptor ferrules are Valcon polyimide, a unique graphite-reinforced composite, specially prepared to maximize mechanical stability at temperatures to 350 °C. The determining factor for selecting adaptor ferrule size is the fused silica tubing OD. View Product Information |
Replacement Ferrules (1/32-Inch Stainless Steel)for MXT® Connectors |
![]() |
Two-Hole Ferrulesfor 1/8-Inch and 1/16-Inch Compression-Type Fittings
View Product Information |
Vu-Union® Graphite Ferrules
View Product Information |
Vu-Union® Vespel®/Graphite Ferrules
View Product Information |
Ferrule Removal KitThe tapered tools in this kit have teeth designed to grip and remove fused silica adaptor ferrules that have become stuck in the fitting detail. Each kit has two tools: one for removing 1/32-inch adaptor ferrules and one for removing 1/16-inch adaptor ferrules. View Product Information |
Stainless Steel Jet ReamersA great tool for cleaning detector jets or removing stuck ferrules from other small orifices. Serrated design is optimal for removing silica deposits and other contaminants. View Product Information |
Septum Puller
View Product Information |
4″ Tapered Needle FilesThese files can be used for many purposes. They are especially useful for removing ferrules that are lodged in injector or detector ports. View Product Information |
Mini Hand Drill SetDrill ferrules to the proper ID in seconds! Includes three drills, for use with 0.25, 0.32, and 0.53 mm ID (0.4, 0.5, and 0.8 mm OD) capillary columns. View Product Information |

