Maintenance Supplies for Capillary Columns

Maintenance Supplies for Capillary Columns

Products

Ceramic Scoring Wafer

  • Four straight scoring edges for cutting fused silica tubing and four serrated edges for cutting MXT® metal capillary columns.

View Product Information

Scoring Wafer with Handle

  • Ceramic wafer is straight-edged for cutting fused silica tubing cleanly.
  • Unique, ergonomic handle is made of soft, comfortable rubber.

View Product Information

Capillary Column Caps

  • Attach to the column in seconds to form an airtight seal.
  • Increase column lifetime—prevent moisture and air from entering the column during storage.
  • Two styles to choose from: glass or silicone material.
  • Glass caps are color-coded for identifying detector and injector ends.
  • Not recommended for reuse.

View Product Information

High-Temperature String

  • Withstands temperatures to 400 °C.
  • Use to restring capillary columns, attach column connectors to column cages, or hold a column in the GC oven.

View Product Information

Pocket Magnifier

  • Small and easy to handle.
  • 10x magnification makes it easy to see the column end to verify a square cut.

View Product Information

Slide-Lock Tweezers and 15 cm Compact Steel Ruler

  • “Lock” capillary columns to the correct insertion distance recommended by the instrument manufacturer during installation.
  • Useful for many laboratory tasks.

View Product Information

Column Hangers

  • Secure, short-term storage.
  • Easily attaches to side of GC.
  • Includes 4 capillary column caps for sealing columns.

View Product Information

Column Hanger

for Agilent 7890, 6890, 5890, and 5880A GCs

Methane Cylinder Kit

(For optimizing linear velocity)

Setting the column flow rate by injecting methane and optimizing linear velocity is a preferred method for establishing reproducible retention times (ASTM Method E1510-93). The kit includes a Scotty® 14 cylinder containing 1% methane in helium, a MINICYL regulator, a syringe adaptor, and a package of twenty-five septa for the adaptor.

View Product Information

Restek Tubing Scorer

for MXT® Columns

  • Makes a perfect cut every time.
  • Easy to use.
  • Leaves column entrance perfectly round.
  • Ideal for creating a leak-free seal with connectors and valves.

View Product Information

Shortix® Capillary GC Column Cutter

  • Consistently make precise, clean, square cuts with a diamond blade.
  • Built-in magnifier to verify square cut.
  • Use with 0.25 mm ID to 0.53 mm ID tubing (0.78 mm OD maximum).

View Product Information

Capillary Column Rinsing Reservoir Kit

Restore the performance of bonded-phase capillary columns by dissolving and removing soluble, nonvolatile residue, using this reservoir kit. The 50 ml rinsing reservoir is equipped with 1/4-inch inlet and outlet connections and includes a built-in fritted disk to prevent particulate matter from contaminating the column. The kit includes: reservoir, pressure regulator, fittings, ferrules, and tubing. Reservoir also available separately.

View Product Information

MXT® Needle Files

Multi-purpose files especially useful for cutting Siltek® treated stainless steel columns.

View Product Information

Sapphire Scribe

  • Cuts fused silica tubing.
  • Produces a clean, square cut.

View Product Information