 Includes a 1/4-inch stainless steel nut and graphite ferrule for attaching the liner to the GC inlet and a 1/4 to 1/16-inch stainless steel reducer, plus a 1/4-inch and 0.5 mm ID graphite ferrule for attaching the column to the liner. View Product Information |
 for 1/4-Inch Packed Injection Port Conversion- Reduces solvent tailing.
- Versatile—0.53 mm ID version can be used in the direct (DI) or on-column (OC) injection mode.
- Incorporates a gentle taper that seals the column and reduces dead volume in direct injection mode.
- Available in various designs.
View Product Information |
 for 1/4″ Injection Ports- Use 1/8″ and 3/16″ OD columns in 1/4″ on-column injection ports.
- Centers column perfectly in injection port to eliminate bent syringe needles.
- Slotted design prevents carrier gas occlusion.
- Vespel®/graphite reducing ferrules make installation easy.
- Includes all nuts & ferrules used to attach tubing to the injector or detector.
View Product Information |
 |
 (for 1/4-inch packed column inlets)- Designed with a glass spiral to promote sample vaporization and provide even sample distribution to the two columns.
- Traps sample residue and minimizes the need for guard columns.
- Press-Tight® taper in each outlet leg facilitates a perfect dead-volume-free connection to each analytical column (OD 0.4 to 0.8 mm) and allows visual confirmation of the column connection.
View Product Information |
 for Agilent 5890 Packed Column GC- Tolerances closely controlled.
- Can be removed from the septum nut weldment.
- Deactivated and fully inert to active compounds!
View Product Information |
 for Agilent 5890 Packed Column GC- Press-Tight® taper forms dead volume free connection to column.
- Minimizes solvent and peak tailing.
- Use with 0.25, 0.32, and 0.53 mm ID capillary columns.
- Can be removed from the septum nut weldment.
View Product Information |
 for Agilent 5890 Packed Column GC- Uses standard 1/16-inch capillary nut and ferrules.
- Convenient wrench pad at base.
- Includes 1/4-inch graphite ferrule and stainless steel nut.
- Use with Agilent or Restek DI glass inserts or Restek DI Uniliner® liners for an Agilent 5890 packed column GC.
View Product Information |
 for 1/4-Inch Packed Injection Port Conversion- Visually observe the Press-Tight® connection between the column end and liner.
- Fit 0.32 and 0.53 mm ID capillary columns (column ODs from 0.5 mm to 0.8 mm).
- Slotted top prevents obstruction of carrier gas flow.
- Two designs available.
- Operate in the direct injection mode.
View Product Information |
 - Visually observe the Press-Tight® connection between the column end and liner.
- Fit 0.32 and 0.53 mm ID capillary columns (column ODs from 0.5 mm to 0.8 mm).
- Slotted top prevents obstruction of carrier gas flow.
- Two designs available.
- Operate in the direct injection mode.
View Product Information |
 |
 (for 1/4-inch packed column inlets)- Inverted cup design offers complete sample vaporization.
- Permits larger sample volumes.
- Incorporates a Press-Tight® taper in each outlet leg, to make a perfect, dead-volume-free connection to each analytical column (ODs ranging from 0.4 to 0.8 mm).
- Allows visual confirmation of the column connection.
- Open-top design makes it easy to pack with glass wool, keeping sample residue from contaminating the cup.
View Product Information |
 |
 |
 |
 |