Ultra-High Purity Regulators

Ultra-High Purity Regulators

Products

Dual-Stage Ultra-High Purity Chrome-Plated Brass Gas Regulators

  • Oxidation-resistant, chrome-plated.
  • Most stable outlet pressure control.
  • Secondary pressure regulation not needed.
  • Most widely used regulator.
  • Less internal volume than stainless steel gas regulators.

View Product Information

Ultra-High Purity Chrome-Plated Brass Line Gas Regulator

  • Oxidation-resistant, chrome-plated.
  • Use where you need to reduce the line pressure by 20 psig (138 kPa) or more.
  • Same purity protection as high-pressure cylinder regulators.

View Product Information

Dual-Stage Ultra-High Purity Stainless Steel Gas Regulators

  • Most stable outlet pressure control.
  • Secondary pressure regulation not needed.

View Product Information

Single-Stage Ultra-High Purity Chrome-Plated Brass Gas Regulators

  • Oxidation-resistant, chrome-plated.
  • Use when there is secondary pressure regulation downstream.
  • Identical gas purity protection as with dual-stage gas regulators.

View Product Information

Single-Stage Ultra-High Purity Stainless Steel Gas Regulators

  • Use when there is secondary pressure regulation downstream.
  • Identical gas purity protection as with dual-stage gas regulators.

View Product Information

Silcosteel® Regulators (Dual Stage & Single Stage)

Applications:
  • CEM Continuous Emission Monitoring
  • Environmental Stack and Gas Emission Standards
  • Low level sulfur and mercury analysis
  • Reactive or corrosive gases
  • Off-shore platform systems
  • Corrosive and salt water exposure

    Outlet pressure: 0 to 100 psig
    Outlet gauge: 30″ – 0 to 200 psig
    Inlet gauge: 0 to 4000 psig
    Outlet assembly: diaphragm valve, 1/4″ tube fitting

View Product Information

CGA Fittings

CGA-specified nuts and nipples with internal frit, 1/4-inch NPT nickel-plated brass.

View Product Information

Cylinder Holders, Wall Mounted

Prevent serious injuries! These holders are designed to prevent free-standing gas cylinders from tipping over and injuring personnel. The cast aluminum holder can be secured to a wall or the side of a work bench. Each mount will secure a cylinder 4-15 inches in diameter.

View Product Information

MINICYL Regulator

This compact general purpose regulator has many laboratory applications including air-drying glassware, sparging or evaporating solutions, and controlling pneumatic valves. It is constructed of lightweight aluminum with an elastomer diaphragm. Includes a 0–60 psig (0-414 kPa) gauge and either 1/8- or 1/4-inch tube fittings.

View Product Information

Flammable Gas Flash Arrestor—Factory Mutual Approved*

  • Gas flow shuts off in the event of a flashback.
  • Flame extinguished—flame front prevented from reaching the gas supply.
  • No gas flow restriction under normal operating conditions.

View Product Information

Protocol Station

The protocol station is designed for convenient wall mounting of high-purity gas regulators. Wall mounting provides ease of use, prevents gas regulator damage, and improves safety. Either chrome-plated brass or 316 stainless steel option is complete with a 3-foot, flexible, all-stainless-steel pigtail with armor casing. The CGA connection on the pigtail has an integral check valve in the gland to prevent contamination during cylinder changeout.

View Product Information

Critical Purity Automatic Switchover System for Noncorrosive Gases

High-purity automatic switchover systems provide a continuous supply of high purity gas to the laboratory, process, or instrument, to allow you to replace a depleted gas source without interruption in the gas supply. Continuous gas supply is achieved by setting the two regulators at slightly different pressures and discharging one side of the system at a time. These models include flexible, all-stainless-steel pigtails with armor casing. The CGA connection on each pigtail has a check valve in the gland to prevent contamination and minimize purging requirements.

View Product Information