Instrument Accessories & Parts

Instrument Accessories & Parts

Products

Preventive Maintenance Kit

for Agilent HPLC Systems

Pump Maintenance Kit

for Agilent HPLC Systems

Preventive Maintenance Kit

for Waters 717 Autosampler

Preventive Maintenance Kits

for Waters HPLC Systems

Stator Face Assembly

for Agilent HPLC Systems

Standard Pump Seal Kit

for PerkinElmer HPLC Systems

Plunger Seals

for Thermo HPLC Systems

Sapphire Plunger

for Thermo HPLC Systems

Check Valve Cartridge

for Thermo HPLC Systems

Lamps

for Thermo HPLC Systems

Syringe, 500µL

for Thermo HPLC Systems

Syringe Assembly, 250µL

for Thermo HPLC Systems

Rotor Seal Assembly, Rheodyne 7010

for Thermo HPLC Systems

Kel-F Washer

for Thermo HPLC Systems

Plunger Seal, Superseal

for Thermo HPLC Systems

Back-up Seal

for Thermo HPLC Systems

Piston

for Thermo HPLC Systems

Outlet Check Valve Assembly

for Thermo HPLC Systems

Inlet Check Valve Assembly

for Thermo HPLC Systems

Injector Lubricant

for Agilent HPLC Systems

Helium Tubing

for Agilent HPLC Systems

Lamps

for Agilent HPLC Systems

Active Inlet Cartridge

for Agilent HPLC Systems

Bottle Head Assembly

for Agilent HPLC Systems

Connecting Tube

for Agilent HPLC Systems

Outlet Cap & Gold Seal Assembly

for Agilent HPLC Systems

Outlet Cap

for Agilent HPLC Systems

Seal, Gold Disk (outlet)

for Agilent HPLC Systems

Frits (PTFE)

for Agilent HPLC Systems

Rotor Seals

for Agilent HPLC Systems

Needle Assembly

for Agilent HPLC Systems

Needle Seat Assembly

for Agilent HPLC Systems

Needle Seats

for Agilent HPLC Systems

Sapphire Pistons

for Agilent HPLC Systems

Wash Seal

for Agilent HPLC Systems

Seal Wash Kit

for Agilent HPLC Systems

Seal Wash Kit, Binary Pump

for Agilent HPLC Systems

Piston Seals

for Agilent HPLC Systems

Check Valve Cartridge Assembly

for Agilent HPLC Systems

Sieves for Outlet Valve

for Agilent HPLC Systems

Outlet Ball Valve

for Agilent HPLC Systems

Outlet Ball Valve, Binary Pump

for Agilent HPLC Systems

Seal Kit, Pump

for Waters HPLC Systems

Seal Pack (Rebuilt - with Needle)

for Waters 717 Autosampler

Battery

for Waters Systems

Reference Valve Rebuild Kit

for Waters HPLC Systems

Face Seals Replacement Kit

for Waters HPLC Systems

Wash Tube Seal Kit

for Waters HPLC Systems

Wash Face Seal

for Waters HPLC Systems

Ferrule (Stainless Steel)

for Waters HPLC Systems

Inlet Manifold Kit

for Waters HPLC Systems

Draw-Off Tube Assembly

for Waters HPLC Systems

Sapphire Plunger Assembly Kit

for Waters HPLC Systems

Sapphire Plungers

for Waters HPLC Systems

Insert Seal Parts Kit

for Waters HPLC Systems

Head Plunger Seal Kits

for Waters HPLC Systems

Seal Wash Plunger Seal

for Waters HPLC Systems

Plunger Seals

for Waters HPLC Systems

Super Seal for Analytical Heads

for Waters HPLC Systems

Check Valve Cartridges

for Waters HPLC Systems

Outlet Check Valve Rebuild Kit

for Waters HPLC Systems

Outlet Check Valve Housing

for Waters HPLC Systems

Outlet Check Valve Assembly

for Waters HPLC Systems

Inlet Check Valve Rebuild Kit

for Waters HPLC Systems

Inlet Check Valve Housing

for Waters HPLC Systems

Inlet Check Valve Assembly

for Waters HPLC Systems

Deuterium Lamps

for Waters Detectors

Xenon Lamps

for Waters Detectors

Quartz Lens

for Waters Detectors

Lamp Side Gasket

for Waters Detectors

Window Gasket

for Waters Detectors

Isolation Seal

for Waters HPLC Systems: Rheodyne® Style

Vespel Rotor Seal

for Waters HPLC Systems: Rheodyne® Style

ASI Replacement HPLC Pump Piston Rods

for Agilent Systems

Buffer salts and metals from the HPLC system become imbedded on the surface of the piston seal and gradually wear the surface of the piston rod. Worn regions on the rod will quickly destroy the pump seals. In turn, the seal material gets trapped on the frit at the head of the column, which leads to increased system pressure and/or irregular or poor peak shape. As the piston continues to wear, a leak may develop at the pump.

View Product Information

ASI Replacement HPLC Pump Piston Rods

for Waters Systems

Buffer salts and metals from the HPLC system become imbedded on the surface of the piston seal and gradually wear the surface of the piston rod. Worn regions on the rod will quickly destroy the pump seals. In turn, the seal material gets trapped on the frit at the head of the column, which leads to increased system pressure and/or irregular or poor peak shape. As the piston continues to wear, a leak may develop at the pump.

View Product Information

Deuterium Lamp (Prealigned)

for Hitachi HPLC Systems

Rotor Seal Kit

for Hitachi HPLC Systems

Rotor Assembly for Dilutor Valve

for Hitachi HPLC Systems

Plunger Seals

for Hitachi HPLC Systems

Plunger Assembly

for Hitachi HPLC Systems

Outlet Check Valve Assembly

for Hitachi HPLC Systems

Inlet Check Valve Assembly

for Hitachi HPLC Systems

Check Valve Cartridges

for Hitachi HPLC Systems

Deuterium Lamp

for Beckman HPLC Systems

Plunger Wash Seal

for Beckman HPLC Systems

Pump Seal

for Beckman HPLC Systems

Sapphire Plunger

for Beckman HPLC Systems

Plunger Seals

for Beckman HPLC Systems

Plunger

for Beckman HPLC Systems

Piston Guide Assembly

for Beckman HPLC Systems

Outlet Check Filter Frit Assembly

for Beckman HPLC Systems

Outlet Check Valve Assembly

for Beckman HPLC Systems

Inlet Check Valve Assembly

for Beckman HPLC Systems

Deuterium Lamps

for Shimadzu HPLC Systems

Plunger Assembly

for Shimadzu HPLC Systems

Syringe

for Shimadzu HPLC Systems

Stator Assembly

for Shimadzu HPLC Systems

Rotor Seal Assembly

for Shimadzu HPLC Systems

Rotor Seal

for Shimadzu HPLC Systems

Needle Seal

for Shimadzu HPLC Systems

Sapphire Plungers

for Shimadzu HPLC Systems

Plunger Rinse Seal

for Shimadzu HPLC Systems

Plunger Seals

for Shimadzu HPLC Systems

Outlet Check Valve Rebuild Kit

for Shimadzu HPLC Systems

Outlet Check Valves

for Shimadzu HPLC Systems

Inlet Check Valves

for Shimadzu HPLC Systems

Deuterium Lamps

for PerkinElmer HPLC Systems

Needle

for PerkinElmer HPLC Systems

Low Pressure Seal

for PerkinElmer HPLC Systems

Standard High Pressure Seal

for PerkinElmer HPLC Systems

High Pressure Seal Kit

for PerkinElmer HPLC Systems

Outlet Check Valve

for PerkinElmer HPLC Systems

Inlet Check Valve

for PerkinElmer HPLC Systems

Outlet Cap and Gold Seal Assembly Tool

for Agilent 1050 & 1100 HPLC Systems

Easily install the gold seal into the outlet cap.

View Product Information

Capillary Stainless Steel Tubing Assemblies

for Agilent HPLC Systems

  • Precut, micropolished tubing and preseated fittings for quick, easy maintenance of your Agilent HPLC systems.
  • Meet or exceed manufacturer's performance.

View Product Information

ASI Piston Seals

for Agilent HPLC Systems

Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed of Teflon® material with an additive that reduces their tendency to “cold flow” and improves their wear characteristics. Teflon® seals are more resistant to any HPLC solvent than UHMWPE seals, but they are less wear-resistant and rugged. For Agilent 1050 and 1100 HPLC systems.

View Product Information

ASI Check Valves

for Waters 616 SS

ASI subjects each valve to a rigorous series of tests, including self-priming capability, which means you typically won’t need a syringe or draw-off valves to prime your pump. A high-pressure test ensures that the valve will not leak, even at pressures up to 12,000psi (82,737kPa). A low-pressure test verifies that the valve closes properly, even without a high backpressure force. The cartridge design allows easy, convenient replacement of worn or damaged valves.

View Product Information

ASI Check Valves

for Waters Alliance® Model 2690 & 2695

ASI subjects each valve to a rigorous series of tests, including self-priming capability, which means you typically won’t need a syringe or draw-off valves to prime your pump. A high-pressure test ensures that the valve will not leak, even at pressures up to 12,000 psi (82,737 kPa). A low-pressure test verifies that the valve closes properly, even without a high backpressure force. The cartridge design allows easy, convenient replacement of worn or damaged valves.

View Product Information

ASI Check Valves

for Agilent 1050 & 1100

ASI subjects each valve to a rigorous series of tests, including self-priming capability, which means you typically won’t need a syringe or draw-off valves to prime your pump. A high-pressure test ensures that the valve will not leak, even at pressures up to 12,000 psi (82,737 kPa). A low-pressure test verifies that the valve closes properly, even without a high backpressure force. The cartridge design allows easy, convenient replacement of worn or damaged valves.

View Product Information