Tools & Maintenance

Products

Survival Kit for HPLC, Stainless Steel

For start-up and maintenance in all HPLC systems.

The stainless steel survival kit contains a wide range of tubing, fittings, and tools necessary to set up and maintain your HPLC system: a selection of lengths and IDs of 1/16-inch tubing, plus nuts, ferrules, a ValvTool wrench, and a zero-dead-volume union.

View Product Information

Survival Kit for HPLC, PEEK

For start-up and maintenance in all HPLC systems.

The PEEK Survival Kit is an invaluable parts kit that contains tubing, fittings, and tools essential for setting up and maintaining your HPLC system: PEEK tubing, connectors, and elbows, Teflon® tubing, a tubing cutter and extra blades, a ValvTool wrench, open-end wrenches, and more.

View Product Information

LC Maintenance Kits

Simplify routine maintenance with these handy kits for LC.

  • Significant savings over instrument manufacturer prices.
  • High quality components in every kit.
  • Wide selection of PM Kits for your HPLC systems.

View Product Information

HPLC PEEK Performance Kit

This HPLC PEEK Performance Kit is a useful complement to your HPLC system.

View Product Information

Outlet Cap and Gold Seal Assembly Tool

for Agilent 1050 & 1100 HPLC Systems

Easily install the gold seal into the outlet cap.

View Product Information

PEEK Fitting Extractor

Drill into the broken fitting, then screw the extractor into the fitting and remove it easily. Eliminates the need for heat or other techniques that could damage your column.

View Product Information

HPLC Piston Seal Insertion Tool

Simplify pump maintenance: use one end to remove your old seal, then simply slip your new seal on the other end and push it flush into position. The tool cannot mar the surrounding metal surface of the pump housing.

View Product Information

Tubing Dressing Tool

Opens stainless steel tubing bore and removes burrs. For 1/16-inch OD tubing or 1/8-inch OD tubing.

View Product Information

Clean-Cut Tubing Cutter

  • Burr-free, perpendicular cuts that will not distort the tubing OD or close the ID.
  • Use on PEEK, Teflon®, Tefzel®, other polymeric tubing.

View Product Information

ValvTool Wrench

The ValvTool is a time-saving device that provides easy access to many hard-to-reach Rheodyne® or Valco® valves. For 1/4-inch nuts.

View Product Information

Tubing Clip

Securely holds 1/16-inch or 1/8-inch tubing in beaker, flask, or bottle up to 4 mm thick.

View Product Information