Restek Advantage Chromatography Newsletter Back Issues

Restek Advantage Chromatography Newsletter

2006, Volume 2

Introducing...

New Rxi™ Fused Silica Columns: Restek chemists use new technology and stringent quality control to produce this new family of columns. Rxi™ columns have unsurpassed inertness for sub-nanogram on-column levels of active compounds, and assure reliable column-to-column performance.

Find out more.



Professor Walter Jennings

Preventive Maintenance for GC: Professor Jennings explains the consequences of ignoring those enclosures included with a new column, and offers simple, proven, preventive maintenance options that help avoid downtime.

Find out more.


Environmental

Excellent Responses in GC/MS Analysis of Semivolatiles: The newest members of our new line of Rxi™ columns, Rxi™-1ms columns, offer the same outstanding inertness, ultra-low bleed, and batch-to-batch reproducibility as our Rxi™-5ms columns. Rxi™-1ms columns provide excellent selectivity and symmetric peaks for the diverse chemicals that can make up a semivolatiles sample.

Find out more.


Analysis of Semivolatile Organics: Exceptional inertness and ultra-low bleed enable an Rxi™-5ms column to resolve sub-1ng quantities of acidic or basic analytes under a single set of conditions. In this example analysis, an Rxi™-5ms column separated 93 target analytes in US EPA Method 8270D in less than 18 minutes.

Find out more.


Pharmaceutical

Optimizing Difficult Separations of Steroids Using an Allure™ Biphenyl HPLC Column: Steroids are structurally very similar, and separations on alkyl stationary phases can be difficult. Through a unique separation mechanism — π-π interactions between double bonds in the stationary phase and in the steroid molecules — an Allure™ Biphenyl column greatly enhances selectivity, and resolution. Two examples, sex hormones and corticosteroids, are shown here.

Find out more.


8-Minute GC Analysis of Residual Solvents: Single-injection, dual-column detection/confirmation assay is feasible for regulated solvents in pharmaceutical products, but no temperature program provides sufficient resolution on both columns. Using a Restek G43/G16 column pair and independent temperature programs in a Gerstel MACH column heating system, we analyzed and confirmed 23 Class 2 solvents in 8 minutes.

Find out more.


Simple, Optimized HPLC Analysis of Catecholamines: An Allure™ PFP Propyl column exhibits the retention needed to resolve these active, basic compounds, without derivatization or ion-pairing agents. Selectivity can be adjusted simply by changing the organic modifier in the mostly aqueous mobile phase.

Find out more.


Foods, Flavors & Fragrances

80% Faster GC/MS Analysis of Essential Oils: A 10-meter, 0.10mm ID, 0.10µm film Rtx®-5 column reduces analysis time for bergamot oil or patchouli oil by 80%, for five-fold greater sample throughput and sharply reduced cost per analysis. Sample resolution is unchanged for bergamot oil and is slightly improved for patchouli oil.

Find out more.


Bioanalytical

Improve Characterization of Complex Protein Digests: A Viva C18 wide pore HPLC column resolves a tryptic digest of bovine serum albumin primarily into 1-2 peptide peaks, versus peaks of 3 or more peptides typically provided by conventional C18 columns. This superior resolution helps ensure more reliable identification of peptides in complex mixtures.

Find out more.


Chemical/Petrochemical

Parker ChromGas® Hydrogen Generators: Relative to helium as the GC carrier gas, hydrogen from a gas generator reduces gas costs, cuts analysis time by 50%, and reduces temperatures needed for eluting analytes — which increases column lifetime. Parker ChromGas® hydrogen generators are safe, convenient, reliable, and easy to use.

Find out more.


Clinical/Forensics

GC Inlet Liner Deactivations for Basic Drug Analysis: Basic drugs can interact with active sites on the surface of the inlet liner, reducing responses. The combination of a base-deactivated liner and a base-deactivated Rtx®-5Amine column ensures the greatest responses in analyses for these compounds.

Find out more.


General Interest

How to Condition a New Capillary GC Column: Proper conditioning is essential for optimal performance from a capillary GC column, but inexperienced chromatographers might not know the proper procedures for installing and conditioning a new column. Here, we summarize our recommendations for installation and conditioning procedures.

Find out more.


Featured Restek Products

Analytical Reference Materials:

SOM01.1

HPLC Accessories:

Sidewinder™ Column Heater

Sidewinder™ Heater/Cooler Temperature Control Module

MicroPulse™ Pulse Dampers


GC Accessories:

Dual Vespel® Ring Inlet Seals

Replacement Inlet Seals for Agilent 5890/6890 Split/Splitless Injection Ports

Instrument Innovations!


Recent Publications

These publications are available in printed form or online, as downloadable pdf files.

Find out more.