Ordering Notes
Technical Resources

Selected Product

Cat.#:

List Price:$0.00



Select a Product
catalog #lengthidmodificationunits
9164531
30mm
1.0mm
 
ea.
9164551
50mm
1.0mm
 
ea.
9164511
100mm
1.0mm
 
ea.
9164561
150mm
1.0mm
 
ea.
9164521
200mm
1.0mm
 
ea.
9164571
250mm
1.0mm
 
ea.
9164532
30mm
2.1mm
 
ea.
9164552
50mm
2.1mm
 
ea.
9164512
100mm
2.1mm
 
ea.
9164562
150mm
2.1mm
 
ea.
9164522
200mm
2.1mm
 
ea.
9164572
250mm
2.1mm
 
ea.
9164533
30mm
3.2mm
 
ea.
9164553
50mm
3.2mm
 
ea.
9164513
100mm
3.2mm
 
ea.
9164563
150mm
3.2mm
 
ea.
9164523
200mm
3.2mm
 
ea.
9164573
250mm
3.2mm
 
ea.
9164535
30mm
4.6mm
 
ea.
9164555
50mm
4.6mm
 
ea.
9164515
100mm
4.6mm
 
ea.
9164565
150mm
4.6mm
 
ea.
9164525
200mm
4.6mm
 
ea.
9164575
250mm
4.6mm
 
ea.
9164532-700
30mm
2.1mm
with Trident Inlet Fitting
ea.
9164552-700
50mm
2.1mm
with Trident Inlet Fitting
ea.
9164512-700
100mm
2.1mm
with Trident Inlet Fitting
ea.
9164562-700
150mm
2.1mm
with Trident Inlet Fitting
ea.
9164522-700
200mm
2.1mm
with Trident Inlet Fitting
ea.
9164572-700
250mm
2.1mm
with Trident Inlet Fitting
ea.
9164533-700
30mm
3.2mm
with Trident Inlet Fitting
ea.
9164553-700
50mm
3.2mm
with Trident Inlet Fitting
ea.
9164513-700
100mm
3.2mm
with Trident Inlet Fitting
ea.
9164563-700
150mm
3.2mm
with Trident Inlet Fitting
ea.
9164523-700
200mm
3.2mm
with Trident Inlet Fitting
ea.
9164573-700
250mm
3.2mm
with Trident Inlet Fitting
ea.
9164535-700
30mm
4.6mm
with Trident Inlet Fitting
ea.
9164555-700
50mm
4.6mm
with Trident Inlet Fitting
ea.
9164515-700
100mm
4.6mm
with Trident Inlet Fitting
ea.
9164565-700
150mm
4.6mm
with Trident Inlet Fitting
ea.
9164525-700
200mm
4.6mm
with Trident Inlet Fitting
ea.
9164575-700
250mm
4.6mm
with Trident Inlet Fitting
ea.

Application-dedicated HPLC columns have longer lifetimes

Prolong the useful lifetimes of your HPLC columns by dedicating specific columns to specific applications, like analysts who use ion pair reagents often do. Sample components, mobile phase conditions, etc. can cause changes within a column, and sometimes effects of these changes are negligible until the column is used in another application. Although this practice can involve using more columns at one time, and calls for careful bookkeeping, longer lifetimes for individual columns can amount to significant savings.

Avoid the Void Volume

A speedy analysis is important, but avoid the temptation to elute important sample components near the void volume of your column. When you ignore this guideline, you are locked into using the mobile phase as the sample solvent; any admixing of sample solvent and mobile phase causes a baseline disturbance that makes quantification highly unreliable. Also, it is highly likely that the peak at the void volume will soar off-scale. You will avoid these and other potential problems by adjusting conditions such that the first target compound elutes with a capacity factor (k′) of at least 2.0.