Ordering Notes
Technical Resources

Selected Product

Cat.#:

List Price:$0.00



Select a Product
catalog #Product Namesizeunits
951450212
Viva C18 Guard Cartridge
10 x 2.1 mm
3-pk.
951450210
Viva C18 Guard Cartridge
10 x 4.0 mm
3-pk.
951450222
Viva C18 Guard Cartridge
20 x 2.1 mm
2-pk.
951450220
Viva C18 Guard Cartridge
20 x 4.0 mm
2-pk.
951350212
Viva C8 Guard Cartridge
10 x 2.1 mm
3-pk.
951350210
Viva C8 Guard Cartridge
10 x 4.0 mm
3-pk.
951350222
Viva C8 Guard Cartridge
20 x 2.1 mm
2-pk.
951350220
Viva C8 Guard Cartridge
20 x 4.0 mm
2-pk.
951250212
Viva C4 Guard Cartridge
10 x 2.1 mm
3-pk.
951250210
Viva C4 Guard Cartridge
10 x 4.0 mm
3-pk.
951250222
Viva C4 Guard Cartridge
20 x 2.1 mm
2-pk.
951250220
Viva C4 Guard Cartridge
20 x 4.0 mm
2-pk.
951950212
Viva PFP Propyl Guard Cartridge
10 x 2.1 mm
3-pk.
951950210
Viva PFP Propyl Guard Cartridge
10 x 4.0 mm
3-pk.
951950222
Viva PFP Propyl Guard Cartridge
20 x 2.1 mm
2-pk.
951950220
Viva PFP Propyl Guard Cartridge
20 x 4.0 mm
2-pk.
951650212
Viva Biphenyl Guard Cartridge
10 x 2.1 mm
3-pk.
951650210
Viva Biphenyl Guard Cartridge
10 x 4.0 mm
3-pk.
951650222
Viva Biphenyl Guard Cartridge
20 x 2.1 mm
2-pk.
951650220
Viva Biphenyl Guard Cartridge
20 x 4.0 mm
2-pk.
951050212
Viva Silica Guard Cartridge
10 x 2.1 mm
3-pk.
951050210
Viva Silica Guard Cartridge
10 x 4.0 mm
3-pk.
951050222
Viva Silica Guard Cartridge
20 x 2.1 mm
2-pk.
951050220
Viva Silica Guard Cartridge
20 x 4.0 mm
2-pk.

Managing High Backpressure

High backpressure is one of the most common problems encountered in HPLC analyses. Normal column backpressure is observed after a new column has been installed and equilibrated with mobile phase. Unfortunately, this pressure often will increase as the column is used because particles collect on the column inlet frit. These particles can be sample impurities, mobile phase contaminants, or materials from the injector or autosampler rotor seal. In addition to increasing backpressure, particles on the frit can cause split peaks, peak tailing, and, eventually, over-pressure shut-down. In some circumstances, these problems can be corrected by back-flushing the column. However, in many cases the result is an unusable column. To minimize backpressure problems, all samples and mobile phase solvents must be filtered before use, and rotor seals should be changed on a routine basis. Along with these preventive measures, it is advisable to use precolumn filters such as the Trident guard column protection system. Particles build up on the inexpensive, replaceable frit in the filter, instead of on the permanent frit at the column inlet.