catalog #Product Namesizeunits
915950210
Allure AK Guard Cartridge
10 x 4.0mm
3-pk.
916150212
Allure Basix Guard Cartridge
10 x 2.1mm
3-pk.
916150210
Allure Basix Guard Cartridge
10 x 4.0mm
3-pk.
916150222
Allure Basix Guard Cartridge
20 x 2.1mm
2-pk.
916150220
Allure Basix Guard Cartridge
20 x 4.0mm
2-pk.
916450212
Allure C18 Guard Cartridge
10 x 2.1mm
3-pk.
916450210
Allure C18 Guard Cartridge
10 x 4.0mm
3-pk.
916450222
Allure C18 Guard Cartridge
20 x 2.1mm
2-pk.
916450220
Allure C18 Guard Cartridge
20 x 4.0mm
2-pk.
916950212
Allure PFP Propyl Guard Cartridge
10 x 2.1mm
3-pk.
916950210
Allure PFP Propyl Guard Cartridge
10 x 4.0mm
3-pk.
916950222
Allure PFP Propyl Guard Cartridge
20 x 2.1mm
2-pk.
916950220
Allure PFP Propyl Guard Cartridge
20 x 4.0mm
2-pk.
916050212
Allure Silica Guard Cartridge
10 x 2.1mm
3-pk.
916050210
Allure Silica Guard Cartridge
10 x 4.0mm
3-pk.
916050222
Allure Silica Guard Cartridge
20 x 2.1mm
2-pk.
916050220
Allure Silica Guard Cartridge
20 x 4.0mm
2-pk.
916550212
Allure Organic Acids Guard Cartridge
10 x 2.1mm
3-pk.
916550210
Allure Organic Acids Guard Cartridge
10 x 4.0mm
3-pk.
916550222
Allure Organic Acids Guard Cartridge
20 x 2.1mm
2-pk.
916550220
Allure Organic Acids Guard Cartridge
20 x 4.0mm
2-pk.
916850212
Allure Aqueous C18 Guard Cartridge
10 x 2.1mm
3-pk.
916850210
Allure Aqueous C18 Guard Cartridge
10 x 4.0mm
3-pk.
916850222
Allure Aqueous C18 Guard Cartridge
20 x 2.1mm
2-pk.
916850220
Allure Aqueous C18 Guard Cartridge
20 x 4.0mm
2-pk.
916650212
Allure Biphenyl Guard Cartridge
10 x 2.1mm
3-pk.
916650210
Allure Biphenyl Guard Cartridge
10 x 4.0mm
3-pk.
916650222
Allure Biphenyl Guard Cartridge
20 x 2.1mm
2-pk.
916650220
Allure Biphenyl Guard Cartridge
20 x 4.0mm
2-pk.

Managing High Backpressure

High backpressure is one of the most common problems encountered in HPLC analyses. Normal column backpressure is observed after a new column has been installed and equilibrated with mobile phase. Unfortunately, this pressure often will increase as the column is used because particles collect on the column inlet frit. These particles can be sample impurities, mobile phase contaminants, or materials from the injector or autosampler rotor seal. In addition to increasing backpressure, particles on the frit can cause split peaks, peak tailing, and, eventually, over-pressure shut-down. In some circumstances, these problems can be corrected by back-flushing the column. However, in many cases the result is an unusable column. To minimize backpressure problems, all samples and mobile phase solvents must be filtered before use, and rotor seals should be changed on a routine basis. Along with these preventive measures, it is advisable to use precolumn filters such as the Trident guard column protection system. Particles build up on the inexpensive, replaceable frit in the filter, instead of on the permanent frit at the column inlet.