Ordering Notes
Technical Resources

Selected Product

Cat.#:

List Price:$0.00



Select a Product
catalog #Product Namesizeunits
921750212
Pinnacle II Amino Guard Cartridge
10 x 2.1mm
3-pk.
921750210
Pinnacle II Amino Guard Cartridge
10 x 4.0mm
3-pk.
921750222
Pinnacle II Amino Guard Cartridge
20 x 2.1mm
2-pk.
921750220
Pinnacle II Amino Guard Cartridge
20 x 4.0mm
2-pk.
921350212
Pinnacle II C8 Guard Cartridge
10 x 2.1mm
3-pk.
921350210
Pinnacle II C8 Guard Cartridge
10 x 4.0mm
3-pk.
921350222
Pinnacle II C8 Guard Cartridge
20 x 2.1mm
2-pk.
921350220
Pinnacle II C8 Guard Cartridge
20 x 4.0mm
2-pk.
921450212
Pinnacle II C18 Guard Cartridge
10 x 2.1mm
3-pk.
921450210
Pinnacle II C18 Guard Cartridge
10 x 4.0mm
3-pk.
921450222
Pinnacle II C18 Guard Cartridge
20 x 2.1mm
2-pk.
921450220
Pinnacle II C18 Guard Cartridge
20 x 4.0mm
2-pk.
921650212
Pinnacle II Cyano Guard Cartridge
10 x 2.1mm
3-pk.
921650210
Pinnacle II Cyano Guard Cartridge
10 x 4.0mm
3-pk.
921650222
Pinnacle II Cyano Guard Cartridge
20 x 2.1mm
2-pk.
921650220
Pinnacle II Cyano Guard Cartridge
20 x 4.0mm
2-pk.
921950212
Pinnacle II PAH Guard Cartridge
10 x 2.1mm
3-pk.
921950210
Pinnacle II PAH Guard Cartridge
10 x 4.0mm
3-pk.
921950222
Pinnacle II PAH Guard Cartridge
20 x 2.1mm
2-pk.
921950220
Pinnacle II PAH Guard Cartridge
20 x 4.0mm
2-pk.
920950210
Pinnacle II Biphenyl Guard Cartridge
10 x 4.0mm
3-pk.
920950220
Pinnacle II Biphenyl Guard Cartridge
20 x 4.0mm
2-pk.
921050212
Pinnacle II Silica Guard Cartridge
10 x 2.1mm
3-pk.
921050210
Pinnacle II Silica Guard Cartridge
10 x 4.0mm
3-pk.
921050222
Pinnacle II Silica Guard Cartridge
20 x 2.1mm
2-pk.
921050220
Pinnacle II Silica Guard Cartridge
20 x 4.0mm
2-pk.

Managing High Backpressure

High backpressure is one of the most common problems encountered in HPLC analyses. Normal column backpressure is observed after a new column has been installed and equilibrated with mobile phase. Unfortunately, this pressure often will increase as the column is used because particles collect on the column inlet frit. These particles can be sample impurities, mobile phase contaminants, or materials from the injector or autosampler rotor seal. In addition to increasing backpressure, particles on the frit can cause split peaks, peak tailing, and, eventually, over-pressure shut-down. In some circumstances, these problems can be corrected by back-flushing the column. However, in many cases the result is an unusable column. To minimize backpressure problems, all samples and mobile phase solvents must be filtered before use, and rotor seals should be changed on a routine basis. Along with these preventive measures, it is advisable to use precolumn filters such as the Trident guard column protection system. Particles build up on the inexpensive, replaceable frit in the filter, instead of on the permanent frit at the column inlet.