Ordering Notes
Technical Resources

Selected Product

Cat.#:

List Price:$0.00



Select a Product
catalog #Product Namesizeunits
941350212
Pinnacle DB C8 Guard Cartridge
10 x 2.1 mm
3-pk.
941350210
Pinnacle DB C8 Guard Cartridge
10 x 4.0 mm
3-pk.
941350222
Pinnacle DB C8 Guard Cartridge
20 x 2.1 mm
2-pk.
941350220
Pinnacle DB C8 Guard Cartridge
20 x 4.0 mm
2-pk.
941450212
Pinnacle DB C18 Guard Cartridge
10 x 2.1 mm
3-pk.
941450210
Pinnacle DB C18 Guard Cartridge
10 x 4.0 mm
3-pk.
941450222
Pinnacle DB C18 Guard Cartridge
20 x 2.1 mm
2-pk.
941450220
Pinnacle DB C18 Guard Cartridge
20 x 4.0 mm
2-pk.
941850212
Pinnacle DB Aqueous C18 Guard Cartridge
10 x 2.1 mm
3-pk.
941850210
Pinnacle DB Aqueous C18 Guard Cartridge
10 x 4.0 mm
3-pk.
941850222
Pinnacle DB Aqueous C18 Guard Cartridge
20 x 2.1 mm
2-pk.
941850220
Pinnacle DB Aqueous C18 Guard Cartridge
20 x 4.0 mm
2-pk.
940950212
Pinnacle DB Biphenyl Guard Cartridge
10 x 2.1 mm
3-pk.
940950210
Pinnacle DB Biphenyl Guard Cartridge
10 x 4.0 mm
3-pk.
940950222
Pinnacle DB Biphenyl Guard Cartridge
20 x 2.1 mm
2-pk.
940950220
Pinnacle DB Biphenyl Guard Cartridge
20 x 4.0 mm
2-pk.
941950212
Pinnacle DB PFP Propyl Guard Cartridge
10 x 2.1 mm
3-pk.
941950210
Pinnacle DB PFP Propyl Guard Cartridge
10 x 4.0 mm
3-pk.
941950222
Pinnacle DB PFP Propyl Guard Cartridge
20 x 2.1 mm
2-pk.
941950220
Pinnacle DB PFP Propyl Guard Cartridge
20 x 4.0 mm
2-pk.
941650212
Pinnacle DB Cyano Guard Cartridge
10 x 2.1 mm
3-pk.
941650210
Pinnacle DB Cyano Guard Cartridge
10 x 4.0 mm
3-pk.
941650222
Pinnacle DB Cyano Guard Cartridge
20 x 2.1 mm
2-pk.
941650220
Pinnacle DB Cyano Guard Cartridge
20 x 4.0 mm
2-pk.
941050212
Pinnacle DB Silica Guard Cartridge
10 x 2.1 mm
3-pk.
941050210
Pinnacle DB Silica Guard Cartridge
10 x 4.0 mm
3-pk.
941050222
Pinnacle DB Silica Guard Cartridge
20 x 2.1 mm
2-pk.
941050220
Pinnacle DB Silica Guard Cartridge
20 x 4.0 mm
2-pk.

Managing High Backpressure

High backpressure is one of the most common problems encountered in HPLC analyses. Normal column backpressure is observed after a new column has been installed and equilibrated with mobile phase. Unfortunately, this pressure often will increase as the column is used because particles collect on the column inlet frit. These particles can be sample impurities, mobile phase contaminants, or materials from the injector or autosampler rotor seal. In addition to increasing backpressure, particles on the frit can cause split peaks, peak tailing, and, eventually, over-pressure shut-down. In some circumstances, these problems can be corrected by back-flushing the column. However, in many cases the result is an unusable column. To minimize backpressure problems, all samples and mobile phase solvents must be filtered before use, and rotor seals should be changed on a routine basis. Along with these preventive measures, it is advisable to use precolumn filters such as the Trident guard column protection system. Particles build up on the inexpensive, replaceable frit in the filter, instead of on the permanent frit at the column inlet.