Ordering Notes
Technical Resources

Selected Product

Cat.#:

List Price:$0.00



Select a Product
catalog #lengthiddfmodificationunits
12605
15m
0.25mm
0.10μm
 
ea.
12608
30m
0.25mm
0.10μm
 
ea.
12608-124
30m
0.25mm
0.10μm
w/5m Integra-Guard Column
ea.
12611
60m
0.25mm
0.10μm
 
ea.
12620
15m
0.25mm
0.25μm
 
ea.
12620-600
15m
0.25mm
0.25μm
 
6-pk.
12620-124
15m
0.25mm
0.25μm
w/5m Integra-Guard Column
ea.
12620-124600
15m
0.25mm
0.25μm
w/5m Integra-Guard Column
6-pk.
12623
30m
0.25mm
0.25μm
 
ea.
12623-600
30m
0.25mm
0.25μm
 
6-pk.
12623-124
30m
0.25mm
0.25μm
w/5m Integra-Guard Column
ea.
12623-127
30m
0.25mm
0.25μm
w/10m Integra-Guard Column
ea.
12626
60m
0.25mm
0.25μm
 
ea.
12626-124
60m
0.25mm
0.25μm
w/5m Integra-Guard Column
ea.
12626-127
60m
0.25mm
0.25μm
w/10m Integra-Guard Column
ea.
12635
15m
0.25mm
0.50μm
 
ea.
12635-124
15m
0.25mm
0.50μm
w/5m Integra-Guard Column
ea.
12635-127
15m
0.25mm
0.50μm
w/10m Integra-Guard Column
ea.
12638
30m
0.25mm
0.50μm
 
ea.
12638-600
30m
0.25mm
0.50μm
 
6-pk.
12638-124
30m
0.25mm
0.50μm
w/5m Integra-Guard Column
ea.
12638-127
30m
0.25mm
0.50μm
w/10m Integra-Guard Column
ea.
12641
60m
0.25mm
0.50μm
 
ea.
12650
15m
0.25mm
1.00μm
 
ea.
12653
30m
0.25mm
1.00μm
 
ea.
12606
15m
0.32mm
0.10μm
 
ea.
12609
30m
0.32mm
0.10μm
 
ea.
12612
60m
0.32mm
0.10μm
 
ea.
12621
15m
0.32mm
0.25μm
 
ea.
12624
30m
0.32mm
0.25μm
 
ea.
12624-125
30m
0.32mm
0.25μm
w/5m Integra-Guard Column
ea.
12627
60m
0.32mm
0.25μm
 
ea.
12636
15m
0.32mm
0.50μm
 
ea.
12639
30m
0.32mm
0.50μm
 
ea.
12642
60m
0.32mm
0.50μm
 
ea.
12651
15m
0.32mm
1.00μm
 
ea.
12654
30m
0.32mm
1.00μm
 
ea.
12654-125
30m
0.32mm
1.00μm
w/5m Integra-Guard Column
ea.
12637
15m
0.53mm
0.50μm
 
ea.
12640
30m
0.53mm
0.50μm
 
ea.
12652
15m
0.53mm
1.00μm
 
ea.
12655
30m
0.53mm
1.00μm
 
ea.
12667
15m
0.53mm
1.50μm
 
ea.
12670
30m
0.53mm
1.50μm
 
ea.

GC Column Installation Checklist

Installation Checklist for GC Columns—Restek Innovations and Technical Services specialists have found this checklist to be a reliable sequence for avoiding problems when installing a capillary GC column.

What are the differences between Rtx®-5MS columns and Rtx®-5Sil MS columns?

Rtx®-5MS columns are coated with a 5% diphenyl/95% dimethyl polysiloxane phase and are tested to rigorous specifications for low bleed and inertness. They have polarity identical to Rtx®-5 columns, but exhibit lower bleed. Rtx®-5Sil MS columns are coated with a silarylene phase that exhibits polarity very similar to a 5% diphenyl/95% dimethyl polysiloxane phase, but the phenyl rings in the polymer chain of the silarylene phase impart improved thermal stability and lower bleed. The Rtx®-5Sil MS column is an ideal choice for analyzing EPA Method 8270 semivolatile pollutants. The slight difference in the polarity of Rtx®-5Sil MS columns also improves separation of benzo(b)- and benzo(k)- fluoranthene isomers.