Ordering Notes
Technical Resources

Selected Product

Cat.#:

List Price:$0.00



Select a Product
catalog #lengthiddfmodificationunits
12605
15 m
0.25 mm
0.10 μm
ea.
12608
30 m
0.25 mm
0.10 μm
ea.
12608-124
30 m
0.25 mm
0.10 μm
w/5 m Integra-Guard Column
ea.
12611
60 m
0.25 mm
0.10 μm
ea.
12620
15 m
0.25 mm
0.25 μm
ea.
12620-600
15 m
0.25 mm
0.25 μm
6-pk.
12620-124
15 m
0.25 mm
0.25 μm
w/5 m Integra-Guard Column
ea.
12620-124600
15 m
0.25 mm
0.25 μm
w/5 m Integra-Guard Column
6-pk.
12623
30 m
0.25 mm
0.25 μm
ea.
12623-600
30 m
0.25 mm
0.25 μm
6-pk.
12623-124
30 m
0.25 mm
0.25 μm
w/5 m Integra-Guard Column
ea.
12623-127
30 m
0.25 mm
0.25 μm
w/10 m Integra-Guard Column
ea.
12626
60 m
0.25 mm
0.25 μm
ea.
12626-124
60 m
0.25 mm
0.25 μm
w/5 m Integra-Guard Column
ea.
12626-127
60 m
0.25 mm
0.25 μm
w/10 m Integra-Guard Column
ea.
12635
15 m
0.25 mm
0.50 μm
ea.
12635-124
15 m
0.25 mm
0.50 μm
w/5 m Integra-Guard Column
ea.
12635-127
15 m
0.25 mm
0.50 μm
w/10 m Integra-Guard Column
ea.
12638
30 m
0.25 mm
0.50 μm
ea.
12638-600
30 m
0.25 mm
0.50 μm
6-pk.
12638-124
30 m
0.25 mm
0.50 μm
w/5 m Integra-Guard Column
ea.
12638-127
30 m
0.25 mm
0.50 μm
w/10 m Integra-Guard Column
ea.
12641
60 m
0.25 mm
0.50 μm
ea.
12650
15 m
0.25 mm
1.00 μm
ea.
12653
30 m
0.25 mm
1.00 μm
ea.
12606
15 m
0.32 mm
0.10 μm
ea.
12609
30 m
0.32 mm
0.10 μm
ea.
12612
60 m
0.32 mm
0.10 μm
ea.
12621
15 m
0.32 mm
0.25 μm
ea.
12624
30 m
0.32 mm
0.25 μm
ea.
12624-125
30 m
0.32 mm
0.25 μm
w/5 m Integra-Guard Column
ea.
12627
60 m
0.32 mm
0.25 μm
ea.
12636
15 m
0.32 mm
0.50 μm
ea.
12639
30 m
0.32 mm
0.50 μm
ea.
12642
60 m
0.32 mm
0.50 μm
ea.
12651
15 m
0.32 mm
1.00 μm
ea.
12654
30 m
0.32 mm
1.00 μm
ea.
12654-125
30 m
0.32 mm
1.00 μm
w/5 m Integra-Guard Column
ea.
12637
15 m
0.53 mm
0.50 μm
ea.
12640
30 m
0.53 mm
0.50 μm
ea.
12652
15 m
0.53 mm
1.00 μm
ea.
12655
30 m
0.53 mm
1.00 μm
ea.
12667
15 m
0.53 mm
1.50 μm
ea.
12670
30 m
0.53 mm
1.50 μm
ea.

GC Column Installation Checklist

Installation Checklist for GC Columns—Restek Innovations and Technical Services specialists have found this checklist to be a reliable sequence for avoiding problems when installing a capillary GC column.

What are the differences between Rtx®-5MS columns and Rtx®-5Sil MS columns?

Rtx®-5MS columns are coated with a 5% diphenyl/95% dimethyl polysiloxane phase and are tested to rigorous specifications for low bleed and inertness. They have polarity identical to Rtx®-5 columns, but exhibit lower bleed. Rtx®-5Sil MS columns are coated with a silarylene phase that exhibits polarity very similar to a 5% diphenyl/95% dimethyl polysiloxane phase, but the phenyl rings in the polymer chain of the silarylene phase impart improved thermal stability and lower bleed. The Rtx®-5Sil MS column is an ideal choice for analyzing EPA Method 8270 semivolatile pollutants. The slight difference in the polarity of Rtx®-5Sil MS columns also improves separation of benzo(b)- and benzo(k)- fluoranthene isomers.