Ordering Notes
Technical Resources

Selected Product

Cat.#:

List Price:$0.00



Select a Product
catalog #lengthidmodificationunits
9219452
50mm
2.1mm
 
ea.
9219412
100mm
2.1mm
 
ea.
9219462
150mm
2.1mm
 
ea.
9219422
200mm
2.1mm
 
ea.
9219472
250mm
2.1mm
 
ea.
9219453
50mm
3.2mm
 
ea.
9219413
100mm
3.2mm
 
ea.
9219463
150mm
3.2mm
 
ea.
9219423
200mm
3.2mm
 
ea.
9219473
250mm
3.2mm
 
ea.
9219455
50mm
4.6mm
 
ea.
9219415
100mm
4.6mm
 
ea.
9219465
150mm
4.6mm
 
ea.
9219425
200mm
4.6mm
 
ea.
9219475
250mm
4.6mm
 
ea.
9219452-700
50mm
2.1mm
with Trident Inlet Fitting
ea.
9219412-700
100mm
2.1mm
with Trident Inlet Fitting
ea.
9219462-700
150mm
2.1mm
with Trident Inlet Fitting
ea.
9219422-700
200mm
2.1mm
with Trident Inlet Fitting
ea.
9219472-700
250mm
2.1mm
with Trident Inlet Fitting
ea.
9219453-700
50mm
3.2mm
with Trident Inlet Fitting
ea.
9219413-700
100mm
3.2mm
with Trident Inlet Fitting
ea.
9219423-700
200mm
3.2mm
with Trident Inlet Fitting
ea.
9219473-700
250mm
3.2mm
with Trident Inlet Fitting
ea.
9219455-700
50mm
4.6mm
with Trident Inlet Fitting
ea.
9219415-700
100mm
4.6mm
with Trident Inlet Fitting
ea.
9219465-700
150mm
4.6mm
with Trident Inlet Fitting
ea.
9219425-700
200mm
4.6mm
with Trident Inlet Fitting
ea.
9219475-700
250mm
4.6mm
with Trident Inlet Fitting
ea.

Application-dedicated HPLC columns have longer lifetimes

Prolong the useful lifetimes of your HPLC columns by dedicating specific columns to specific applications, like analysts who use ion pair reagents often do. Sample components, mobile phase conditions, etc. can cause changes within a column, and sometimes effects of these changes are negligible until the column is used in another application. Although this practice can involve using more columns at one time, and calls for careful bookkeeping, longer lifetimes for individual columns can amount to significant savings.

Avoid the Void Volume

A speedy analysis is important, but avoid the temptation to elute important sample components near the void volume of your column. When you ignore this guideline, you are locked into using the mobile phase as the sample solvent; any admixing of sample solvent and mobile phase causes a baseline disturbance that makes quantification highly unreliable. Also, it is highly likely that the peak at the void volume will soar off-scale. You will avoid these and other potential problems by adjusting conditions such that the first target compound elutes with a capacity factor (k′) of at least 2.0.