Phenol Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Phenol

CAS # 108-95-2


Compound Structure and Properties

Molecular Weight94.1112
FormulaC6H6O
Melting Point40.5 °C, 314 °K, 105 °F
Boiling Point181.7 °C, 455 °K, 359 °F
Density1.07 g/cm3
Solubility in Water8.3 g/100 mL (20 °C)
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Phenol; Carbolic acid; Benzenol; Hydroxybenzene; Izal; Monohydroxybenzene; Monophenol; Oxybenzene; Phenic acid; Phenyl alcohol; Phenyl hydrate; Phenyl hydroxide; Phenylic acid; Phenylic alcohol; PhOH; Benzene, hydroxy-; Benzophenol; Acide carbolique; Baker's P & S liquid & Ointment; Fenol; Fenolo; NCI-C50124; Paoscle; Phenole; Carbolsaure


Application Chromatograms

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi®-5ms (Split Injection)
40 mL of Electronic Cigarette Vapor Collected on a Thermal Desorption Tube and Analyzed on Rtx®-VMS
Semivolatiles on Rtx®-5 with 5 m Integra-Guard® by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi®-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi®-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi®-5Sil MS by U.S. EPA Method 8270
Phenols & Benzidines US EPA Methods 604 & 605 on Rtx®-5
Semivolatiles US EPA Method 8270 on Rtx®-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx®-5Sil MS
Flavor Compounds in Grappa on Stabilwax®-DA
Flavor Compounds in Malt Whiskey on Stabilwax®-DA
Petroleum Oxygenates on Stabilwax®
Phenols and Benzidines by U.S. EPA Methods 604 and 605 on Rtx®-5
0.5 ng Semivolatile Organics with Appendix IX on Rxi®-5Sil MS by U.S. EPA Method 8270
Uracil, Pyridine, and Phenol on Ultra Aqueous C18
Semivolatile Organics w/Appendix IX on Rxi®-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi®-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Malt Whiskey on Stabilwax®-DA
US EPA Method 8270D by GC/MS Rtx®-XLB
Amines & Phenols on Rtx®-5 Amine
Peak Shape Comparison of Early Eluting Semivolatiles Using Split (10:1) and Splitless Injection at 80 °C Oven Start Temp.
Phenols by EPA Method 604 on Rtx®-5
Semivolatiles by EPA Method 8270 on Rxi®-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi®-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi®-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi®-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx®-5MS
Phenols by EPA 604 on MXT®-5
Phenols by EPA Method 604 on Rtx®-200
Cresylic Acids on Stabilwax®-DA