New Injection Port Can Simplify Life in Your Laboratory
by Donna Lidgett, GC Accessories Product Marketing Manager
- No kinked or broken gas lines.
- Change inlet liners faster, easier, and eliminate touching hot surfaces.
- Excellent for Agilent 5890, 6850, 6890, or 7890 GCs; especially advantageous with Agilent GCs equipped with autosamplers.
EZ Twist Top Split/Splitless Injection Port for Agilent GCs
Injection port maintenance should be performed prior to installing any capillary column, and on a routine basis,
based on the number of injections made and the cleanliness of the samples. For optimum system performance, the
injection port liner must be free of sample residue, septum particles, and ferrule fragments, so proper
maintenance includes replacing the injection port liner, critical seals, and septum. Peak shape degradation,
poor reproducibility, sample decomposition, and ghost peaks all are associated with using a dirty liner.
Frequent septum replacement prevents fragmentation and leaks. Multiple injections and continuous exposure to
hot injection port surfaces will decompose the septum and can create particles that can fall into the injection
port liner, where they become a potential source of ghost peaks, loss of inertness, and occluded carrier gas
flow. Therefore, changing septum and inlet liners frequently is essential to maintaining optimum system performance.
Using Restek’s new, unique EZ Twist Top Injection Port, and Restek Cool Tools
(Septum Nut Removal Tool, cat. # 24918, and
Inlet Liner Removal Tool, cat. # 20181—order
separately), you can reduce maintenance time and frustration, and eliminate tangled gas lines and damage that
leads to leaks, while avoiding direct contact with hot metal and glass surfaces.
The gas lines are attached to the EZ Twist Top Shell Weldment (bottom) instead of the weldment (top).
Once the injection port is installed the gas lines are under the GC cover and do not interfere with routine
injection port maintenance, as shown in Figure 1. To remove the weldment and access the liner, simply slip
the Weldment Removal Tool (included in the complete injection port kit) over the weldment (Figure 2), twist,
and remove the weldment. For speed and efficiency, the weldment stays secured in the tool until you are ready
to reattach it. Changing inlet liners in original equipment injection ports was complicated by the gas lines
and sampling tray. Our new injection port makes changing the liner a quick and simple task.
| Figure 1 |
 |
Figure 2 |
 |
 |
 |
 |
 |
| The old way: gas lines can be damaged during routine injection port maintenance. |
 |
The new way: with the EZ Twist Top Injection Port, the gas lines are under the GC cover and are not disturbed during maintenance. |
 |
Simply slip the Weldment Removal Tool over the weldment, then twist and remove the weldment. For speed and efficiency, the weldment stays secured in the Weldment Removal Tool until you reattach it. |
EZ Twist Top Split/Splitless Injection Port for Agilent 5890 GCs
EZ Twist Top Split/Splitless Injection Port for Agilent 6890/6850 GCs
EZ Twist Top Split/Splitless Injection Port with Optional Split Vent for Agilent 6890/6850 GCs
EZ Twist Top Split/Splitless Injection Port for Agilent 7890 GCs
|