Peak Performers

Supplies for Agilent GC/MS Instruments


MSD Conversion Fitting

  • A flat, soft aluminum sealing ring deforms and butt-seals against the MSD interface.
  • A standard Vespel® ferrule seals the column and 1/16-inch stainless steel nut.
  • Fitting is constructed of nickel-plated brass for longevity and softness.
  • Use any standard Vespel® or Vespel®/graphite 1/16-inch ferrule.
  • Includes a 1/16-inch stainless steel nut and two replacement sealing rings. Order ferrules separately.




MSD Source Nut

  • 1.2mm nut bore permits easy removal of ferrules with a standard tapered-needle file (cat.# 20106).
  • Made of brass to prevent thread-stripping on the transfer line.
  • Improved design enhances ease of threading onto the transfer line and improves overall lifetime.



Gold Tip Transfer Line

  • For use with Agilent 5971/5972 MS Systems.
  • Gold-plated for inertness.
  • Meets or exceeds OEM performance.



Capillary Installation Gauge for Agilent 5973 MS

  • Seats ferrules onto column for consistent installations.
  • Made from high-quality stainless steel.




Replacement Interface with Bellows for Agilent 5971/5972 MS

  • Meets or exceeds OEM performance.
  • Made of high-quality stainless steel.





Replacement Interface Guide Tube for Agilent 5971/5972 MS

  • Meets or exceeds OEM performance.
  • Made of high-quality stainless steel.





Replacement Cold Sensor for Agilent 5971/5972 MS Diffusion Pump

  • Meets or exceeds OEM performance.
  • Made of high-quality stainless steel.





Replacement Diffusion Pump Fan Assemblies for Agilent 5971/5972 MS

  • 110/120 VAC






Rough Pump Oil #19 for MSD Pumps, Oil Vacuum Pump

  • Formulated from crude oil stocks known for their durability and line lubricating qualities.
  • Use in Agilent 5973/5972/5971 and GCD mass spec systems, or in other manufacturers’ MSD systems that require rough pump oil.
  • Under average use, the oil in the foreline rough pump should be replaced every six months.








Ion Source Cleaning Powder

  • Use this aluminium oxide powder to clean surfaces that contact the sample or ion beam when you encounter poor sensitivity and inadequate abundances at high masses.









Alumaseal™ Ferrules

  • No more ferrule fragments in the transfer line; aluminum construction, will not crack or fragment.
  • No retightening required after temperature cycles—excellent for GC/MS.
  • Unique two-piece design permanently locks on fused silica tubing without causing breakage.
  • Use with any 1/16-inch compression-type fitting.