Capillary Adaptable FID Replacement Jet for Agilent 5890/6890/6850 GCs

Capillary Dedicated FID Replacement Jet for Agilent 6890/6850/7890 GCs

Packed Column FID Replacement Jets for Agilent 5890/6890/6850 GCs


Which FID Jet Should I Use?

There are two FID jet configurations for Agilent GCs. The longer “adaptable” jet fits both 5890 and 6890 GCs, and can be used with capillary or packed columns. The shorter “dedicated” jet is for the FID in the 6890 GC that is designed only for use with capillary columns.


FID Jet Removal Tool for Agilent 5890/6890/6850/7890 FIDs

Jet Removal Tool
  • Securely grips jet in socket for easy removal or installation.
  • Unique, ergonomic handle—easy to hold.
FID Jet Removal Tool Instructions Step1

Slip tool over FID jet...

FID Jet Removal Tool Instructions Step2

...loosen jet...

FID Jet Removal Tool Instructions Step3

...and remove.


FID Gauge Pack for Agilent 5890 GCs

FID Gauge Pack

Pressure regulators and gauges for air & hydrogen. The 1/8-inch bulkhead allows easy hookup to instrument. Rated for inlet pressures to 250psi (1724kPa), outlet pressures of 0 to 60psi (0-414kPa).


FID Gauge Pack

Direct Replacement FID Collector Assembly Kit for Agilent 5890 GCs

Replacement FID Parts for Agilent 5890 GCs


FID Gauge Pack

Direct Replacement FID Collector Assembly Kit for Agilent 6890/6850/7890 GCs

Replacement FID Parts for Agilent 6890/6850/7890 GCs


FID Gauge Pack

FID Base Weldment for Agilent GCs

  • Meets or exceeds manufacturer’s performance.
  • Includes brass nut.

FID Gauge Pack

Spanner Wrench for Agilent 5890/6890/6850/7890 FID Collector Assemblies

  • Easily remove the nut from the FID collector without damaging the nut.
  • Unique, ergonomic handle—easy to grip.
FID Gauge Pack

Remove FID ignitor castle.

FID Gauge Pack

Easily loosen the nut by aligning the two pins on the bottom of the wrench with the two open slots on the nut...

FID Gauge Pack

...then turn counterclockwise...

FID Gauge Pack

...and remove.