Reference Standards: Nutritional Analysis

Looking for a Specific Compound?

Enter an compound name, synonym, or CAS # below.

Products

Carbohydrate HPLC Performance Check Mix (5 components)

  • For simple sugar analysis by HPLC with refractive index/light scattering detection.
  • Use with a silica column with amino functionality, as recommended by AOAC International.
  • Use as a calibration standard for AACC Method 80-04.
  • Offered dry for enhanced stability.

View Product Information

Neat Fatty Acid Methyl Esters

Use these materials to prepare specific mixtures not commercially available. These products are of the highest purity available, typically 99% by GC/FID analysis. Each compound is packaged under a nitrogen blanket to ensure product stability. A Certificate of Analysis is provided with each ampul.

View Product Information

FAME #12 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #12: oils of mid-range to long chain lengths (C13 - C21)

View Product Information

FAME #9 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #9: oils of mid-range to long chain lengths (C16 - C20)

View Product Information

FAME #8 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #8: oils of short to mid-range chain lengths (C11 - C15)

View Product Information

FAME #7 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #7: oils of short chain lengths (C6 - C10)

View Product Information

FAME #6 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #6: oils of long chain lengths (C20 - C21)

View Product Information

FAME #5 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #5: oils of mid-range to long chain lengths (C16 - C24)

View Product Information

FAME #4 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #4: oils of mid-range to long chain lengths (C16 - C24)

View Product Information

FAME #3 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #3: oils of short to mid-range chain lengths (C8 - C16)

View Product Information

FAME #2 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #2: oils of short to mid-range chain lengths (C6 - C14)

View Product Information

FAME #1 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #1: oils of mid-range chain lengths (C16 - C18)

View Product Information

FAME #15 Mix (8 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #15: peanut oil

View Product Information

FAME #14 Mix (11 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #14: cocoa butter

View Product Information

FAME #13 Mix (14 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

FAME #13: mustard seed oil

View Product Information

AOCS #6 Mix (7 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

AOCS #6: lard, beef or mutton tallow, and palm oil

View Product Information

AOCS #5 Mix (8 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

AOCS #5: coconut, palm kernel, babassu, and ouri-curi oil

View Product Information

AOCS #4 Mix (4 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

AOCS #4: olive, teaseed, and neatsfoot oil

View Product Information

AOCS #3 Mix (10 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

AOCS #3: peanut, rapeseed, and mustard seed oil

View Product Information

AOCS #2 Mix (5 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

AOCS #2: linseed, perilla, hempseed, and rubberseed oil

View Product Information

AOCS #1 Mix (6 components)

This mixture can be used for quantification (AOCS Method CE 1-62) and approximate the compositions of the following types of oils:

AOCS #1: corn, poppy seed, cotton seed, soybean, walnut, safflower, sunflower, rice, bran, and sesame oil

View Product Information