delim
Petroleum & Petrochemical Solutions

Petroleum & Petrochemical Solutions

Rt®-Alumina BOND/MAPD Columns (fused silica PLOT)

  • Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene.
  • Stable response factors make this column ideal for process-type applications where recalibration must be minimized.
  • High loadability reduces peak tailing and improves separations.
  • Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) hydrocarbons and accelerated column regeneration following exposure to water.

    Rt®-Alumina BOND/MAPD PLOT columns are made specifically for the analysis of petrochemicals and downstream products such as ethylene, propylene, butylenes, and butadiene.

    Also available in metal MXT®-Alumina columns!

    Literature: Analyze Trace Polar Hydrocarbons More Accurately and Reliably With New Alumina BOND/MAPD PLOT Columns (1.49 MB PDF)

MXT®-Alumina BOND/MAPD Columns (Siltek®-treated stainless steel PLOT)

  • Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene.
  • Stable response factors make this column ideal for process-type applications where recalibration must be minimized.
  • High loadability reduces peak tailing and improves separations.
  • Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) hydrocarbons and accelerated column regeneration following exposure to water.
  • Metal Siltek®-treated tubing is incredibly durable, allowing MXT® columns to be tightly coiled without breaking for use in smaller GC ovens.
    MXT®-Alumina BOND/MAPD PLOT columns are made specifically for the analysis of petrochemicals and downstream products such as ethylene, propylene, butylenes, and butadiene!

    Also available in fused silica Rt®-Alumina columns!

    Literature: Analyze Trace Polar Hydrocarbons More Accurately and Reliably With New Alumina BOND/MAPD PLOT Columns (1.49 MB PDF)

MXT®-1HT SimDist Column (Siltek® treated stainless steel)

(nonpolar phases)

  • Stable up to 450 °C—lowest bleed for longest column lifetime.
  • Reliably meet all ASTM D6352, D7169, and D7500 specifications.
  • 100% dimethyl polysiloxane phase allows easy comparisons to historical data.

Rtx®-DHA Columns (fused silica)

(Crossbond® 100% dimethyl polysiloxane—optimized for hydrocarbon analysis)

  • Columns meet or exceed all ASTM D6730-01 and CAN/CGSB 3.0 No. 14.3-99 method guidelines; test report for method D6730 supplied with each column.
  • Excellent responses and peak symmetry for polar oxygenates.

    Don't forget: The ASTM D6730 method also requires a tuning column—Rtx®-5 DHA Tuning Column

PIANO & PONA VI Mixes

  • PIANO blends: used for calibrating complex hydrocarbon analyses.
  • PONA-VI: prepared to provide nearly every component that may be encountered in feedstock and finished gasolines.

Restek PLOT Columns

  • New bonding process minimizes particle release, reducing column blockage and protecting instrument parts.
  • More consistent flow means stable retention times in Deans and related flow switching techniques.
  • Outstanding peak symmetry improves impurity analysis for gases, solvents, and hydrocarbons.

Sample Cylinders

  • Swagelok® sample cylinders are made of 304L and 316L stainless steel to resist corrosion.
  • DOT rated to 1,800 and 5,000psig (TPED cylinders rated to 1,450 and 4,350psig), which allows sampling at gas wellheads as well as on-site refineries.
  • Each cylinder is hydrostatically tested to at least 5/3 the working pressure.
  • Sample Cylinder Valves are also available.

Restek Electronic Leak Detector

Don't let a small leak turn into a costly repair—protect your instrument and analytical column by using a Restek Leak Detector.

  • Optimized sample flow path.
  • New ergonomic, hand-held design.
  • Handy probe storage for cleanliness and convenience.

    Restek Recommends: When your Leak Detector batteries need to be replaced, send the unit to us for a routine maintenance review to ensure continued sensitivity and reliability. We will replace not only the batteries, but also the probe and internal/external tubing. We will also recertify your unit. Contact Customer Service to send in your Leak Detector for maintenance (cat. #22839-R).

    Click here for Restek's competitive advantage.

    Click here for an audio slideshow.

Finally! A True Peak Capacity Increase for GCxGC of Petroleum Samples

In their comparison of GC and GCxGC, Blumberg et al stated, “the peak capacity of currently practiced GC×GC does not generally exceed the peak capacity attainable from 1D-GC with the same analysis time…”. Seemingly, Blumberg’s main point was that the typical first dimension column in GCxGC is operated suboptimally. We lengthened this column to “naturally” increase peak widths and present here what we believe is the first “true peak capacity increase” for GCxGC.

Narrated by Jack Cochran, Director of New Business and Technology. Length: 55 minutes

Sulfur in LNG: It's Gone Before You Know It

Accurate quantification of sulfur compounds in LNG is challenging, due to the adsorption of analytes in sample collection devices. This webinar demonstrates how using Sulfinert® treated sample cylinders prevents loss and improves accuracy compared to untreated stainless steel cylinders.

Narrated by Silvia Martinez, Air Innovations Chemist. Length: 22 minutes

High Temperature SimDist Analysis

There are many simulated distillation (SimDist) analyses described in the ASTM methods. The most commonly used are ASTM D2887 and ASTM D7213 for light and mid-distillates (gasoline, diesel), as well as the high temperature simulated distillation of crude oils according to ASTM D6352. This 25-minute live webinar provides technical information on the various SimDist methods and includes discussion of column choices, injection techniques, and pain points such as column bleed.

Narrated by Jaap de Zeeuw. Length: 34.5 minutes

ASTM D 6730 Detailed Hydrocarbon Analysis

This presentation provides an overview of detailed hydrocarbon analysis (DHA) according to ASTM Method D6730, discusses column specifications and critical separations, and explains why not every column is suitable for this analysis.

Narrated by Jaap de Zeeuw, International Specialist GC Consumable Products. Length: 18 minutes

Technical Articles

Petroleum & Petrochemical

Analyze ppb Level Sulfur Compounds Using an Rt®-XLSulfur Micropacked GC Column or an Rtx®-1 Thick Film Capillary GC Column

Trace levels of sulfur compounds are separated and quantified by using an Rtx®-1 capillary column or an Rt®-XLSulfur micropacked column. The latter column is a specially deactivated porous polymer in Sulfinert®-passivated stainless steel tubing.

Petroleum & Petrochemical

Rt®-XLSulfur Packed GC Column for Analysis of Low-Level Sulfur Compounds in C1-C6 Hydrocarbon Streams

Rt®-XLSulfur columns resolve hydrocarbons from sulfur compounds in hydrocarbon process streams, and exhibit excellent inertness with low ppbv levels of sulfurs.

Petroleum & Petrochemical

Improve Trace Analysis of Acetylene, Propadiene, and Methyl Acetylene Impurities With Higher Sample Capacity Alumina MAPD Columns

Rt®-Alumina BOND/MAPD columns offer higher capacity than other MAPD columns and are ideal for analyzing acetylene, propadiene, and methyl acetylene in petroleum gases. Greater capacity improves data accuracy due to better peak symmetry and a wide linear range.

Petroleum & Petrochemical

Analysis of Trace Hydrocarbon Impurities in 1,3-Butadiene Using Optimized Rt®-Alumina BOND/MAPD PLOT Columns

Impurity analysis of 1,3-butadiene on an Rt®-Alumina BOND/MAPD column results in good separation of both light polar impurities (methyl acetylene, propadiene) and 4-vinylcyclohexene, a heavier contaminant that often requires testing on a second column.

Petroleum & Petrochemical

GCxGC Analysis of Complex Petroleum Hydrocarbons: Sulfur Speciation in Diesel

Comprehensive 2D GC, also known as GCxGC, is a powerful technique with a great deal of potential for improving separations of complex petroleum and petrochemical samples that contain hundreds—or even thousands—of components. While GCxGC is still considered emerging technology and is used primarily in research and development labs, it has undergone significant growth in the past few years.

Petroleum & Petrochemical

New Alumina Column Shows Promise for Analyzing Chlorofluorocarbons

Rt®-Alumina BOND/CFC columns provide high retention and high selectivity for volatile halogenated hydrocarbons, without the activity that is usually observed with alumina adsorbents. Chlorofluorocarbon analysis, in particular, can benefit from this new technology.

Petroleum & Petrochemical

Extending the Power of Stabilized PLOT Column Technology to Process GC Analyzers

New metal MXT® PLOT columns offer greater stability than conventional PLOT columns, making them a better choice for process GC analyzer applications. New bonding techniques result in highly reproducible flow characteristics, improved layer stability, and excellent separation efficiencies.

Petroleum & Petrochemical

Stable Sulfur & Mercury Sampling in Refineries Using Siltek® and Sulfinert® Surface Treated Components

Refinery and natural gas samples often contain trace amounts of sulfur- and mercury-containing compounds, which can interfere with reactions, poison catalysts in petrochemical processes, and damage equipment. Because these compounds quickly react with stainless steel surfaces, accurate determination of these compounds is impossible when samples are collected and stored in untreated sample cylinders. Restek's Siltek® and Sulfinert® passivation techniques bond an inert layer into the surface of stainless steel, preventing active compounds from reacting with or adsorbing to the steel.

General Interest

How Much Sensitivity is Needed in a Leak Detector?

Restek's Electronic Leak Detector is sensitive enough to find leaks below instrument pressure decay test levels and is available at a fraction of the cost of other hand-held units.

Petroleum & Petrochemical

Faster DHA Analyses Using Helium or Hydrogen

Rtx®-DHA columns are highly stable and can be run with helium or hydrogen under accelerated conditions. Restek has developed a new DHA method using Rtx®-DHA columns with hydrogen that can double refinery sample throughput.

Petroleum & Petrochemical

Tighten Control of Distillation Processes with the New MXT®-1HT Sim Dist Column

New MXT®-1HT SimDist GC columns outperform competitors, allowing more productive D6352 analyses. Here we demonstrate lower bleed levels and higher efficiency, improving resolution and assuring more samples can be run within method specifications.

PDF Document

Analyze Trace Polar Hydrocarbons More Accurately and Reliably With New Alumina BOND/MAPD PLOT Columns!

Rt®- and MXT®-Alumina BOND/MAPD PLOT columns outperform other MAPD columns for trace analysis of methyl acetylene, acetylene, propadiene, and other polar hydrocarbons. The new deactivation results in more predictable responses, increased capacity, and higher temperature stability. (PDF - 1530kB)

PDF Document

Biodiesel Solutions: Innovative Products for Simple, Reliable Biodiesel Analysis

This flyer includes data demonstrating the performance of recommended GC columns for the analysis of total glycerin, fatty acid methyl esters (FAMEs), and residual methanol in biodiesel. Features a comparison of metal and fused silica columns. (PDF - 1652kB)

PDF Document

ShinCarbon ST Micropacked GC Columns: Above-Ambient Analyses of Permanent Gases and Light Hydrocarbons

A ShinCarbon ST micropacked column will separate hydrogen, oxygen, nitrogen, carbon dioxide, carbon monoxide, and methane in 10 minutes, without cryogenic cooling. This 2-page note also shows separations of light hydrocarbon/permanent gas mixtures, natural gas components, and fluorocarbons. (PDF - 228kB)

PDF Document

Resolve Benzene and Toluene in Spark Ignition Fuels Containing Ethanol

This 2-column set for modified ASTM Method D3606-10 completely resolves benzene from ethanol in reformulated fuels containing ethanol. The aromatic compounds also are fully separated and can easily be quantified using sec-butanol as an internal standard. (PDF - 1852kB)

PDF Document

Detailed Hydrocarbon Analysis Featuring Rtx®-DHA Columns

Superior performance for DHA analysis! Rtx®-DHA columns offer 50% faster run times when used with hydrogen, improved resolution between oxygenates and hydrocarbons, and guaranteed column-to-column reproducibility. These columns also meet or exceed all ASTM and CAN/CGSB method guidelines. (PDF - 3922kB)

PDF Document

Rt®-XLSulfur Packed Column: Specialized Packed and Micropacked Columns for Extra-Low Sulfur Analysis

Rt®-XLSulfur packed and micropacked columns combine a unique, efficient porous polymer packing material and true inertness toward active analytes, to ensure excellent and reliable results in trace-level analyses of hydrogen sulfide, sulfur dioxide, and other lightweight sulfur compounds. (PDF - 370kB)

PDF Document

Restek’s PLOT Column Family — The New Benchmark For Performance!

Restek's PLOT column family is the new benchmark for performance! Our innovative bonding process minimizes particle release, reducing column blockage and protecting instrument parts. More consistent flow means stable retention times in Deans and related flow switching techniques.And outstanding peak symmetry improves impurity analysis for gases, solvents, and hydrocarbons. (PDF - 2463kB)

PDF Document

Accurately Quantify Methanol and Ethanol in E85 Biofuel by D5501 with New Rtx®-DHA-150 Column

Improve D5501 analysis of ethanol biofuel with Rtx®-DHA-150 columns. Reliably separate methanol and isobutane in just 20 minutes, with excellent symmetry for both target alcohols. (PDF - 1828kB)

PDF Document

Increase Productivity: Get More Runs from Your SimDist Setup Using Next Generation MXT®-1HT SimDist Columns

New MXT®-1HT SimDist GC columns are shown to outperform competitors, allowing more productive D6352 analyses. Low bleed levels ensure accurate data and longer column lifetime. High efficiency improves resolution, assuring more samples can be run within method specifications. (PDF - 348kB)

PDF Document

New Solutions for Your Petro Analyses

Chromatograms, technical tips, and products developed specifically for petrochemical testing. Details recommendations for simulated distillation, PLOT column applications, DHA, D3606, biodiesel, permanent gases and hydrocarbons. (PDF - 1573kB)

PDF Document

17 Minute D2712 Analysis of Impurities in Propylene Using PLOT Columns

When analyzing hydrocarbon impurities in propylene by ASTM D2712, using an Rt®-Alumina BOND Na2SO4 PLOT column instead of a packed column setup provides the greatest degree of resolution in the least amount of time. (PDF - 121kB)

PDF Document

GC Analysis of Petroleum Products

MXT®-1 Sim Dist and MXT®-500 Sim Dist columns combine the inertness of fused silica with the durability of stainless steel, meeting all ASTM Method D6352 (petroleum simulated distillation) criteria. MXT®-500 Sim Dist columns have lower bleed and longer lifetimes, but calculated boiling points for aromatics are higher (closer to true values); MXT®-1 Sim Dist columns offer polarity that matches published data. Includes chromatograms. (PDF - 111kB)