Petroleum & Petrochemical Solutions
Rt®-Alumina BOND/MAPD Columns (fused silica PLOT)
|
MXT®-Alumina BOND/MAPD Columns (Siltek®-treated stainless steel PLOT)
|
MXT®-1HT SimDist Column (Siltek® treated stainless steel)(nonpolar phases)
|
Rtx®-DHA Columns (fused silica)(Crossbond® 100% dimethyl polysiloxane—optimized for hydrocarbon analysis)
|
![]() PIANO & PONA VI Mixes
|
![]() Restek PLOT Columns
|
![]() Sample Cylinders
|
Restek Electronic Leak DetectorDon't let a small leak turn into a costly repair—protect your instrument and analytical column by using a Restek Leak Detector.
|
Finally! A True Peak Capacity Increase for GCxGC of Petroleum SamplesIn their comparison of GC and GCxGC, Blumberg et al stated, “the peak capacity of currently practiced GC×GC does not generally exceed the peak capacity attainable from 1D-GC with the same analysis time…”. Seemingly, Blumberg’s main point was that the typical first dimension column in GCxGC is operated suboptimally. We lengthened this column to “naturally” increase peak widths and present here what we believe is the first “true peak capacity increase” for GCxGC. Narrated by Jack Cochran, Director of New Business and Technology. Length: 55 minutes |
Sulfur in LNG: It's Gone Before You Know ItAccurate quantification of sulfur compounds in LNG is challenging, due to the adsorption of analytes in sample collection devices. This webinar demonstrates how using Sulfinert® treated sample cylinders prevents loss and improves accuracy compared to untreated stainless steel cylinders. Narrated by Silvia Martinez, Air Innovations Chemist. Length: 22 minutes |
High Temperature SimDist AnalysisThere are many simulated distillation (SimDist) analyses described in the ASTM methods. The most commonly used are ASTM D2887 and ASTM D7213 for light and mid-distillates (gasoline, diesel), as well as the high temperature simulated distillation of crude oils according to ASTM D6352. This 25-minute live webinar provides technical information on the various SimDist methods and includes discussion of column choices, injection techniques, and pain points such as column bleed. Narrated by Jaap de Zeeuw. Length: 34.5 minutes |
ASTM D 6730 Detailed Hydrocarbon AnalysisThis presentation provides an overview of detailed hydrocarbon analysis (DHA) according to ASTM Method D6730, discusses column specifications and critical separations, and explains why not every column is suitable for this analysis. Narrated by Jaap de Zeeuw, International Specialist GC Consumable Products. Length: 18 minutes |
|
|
![]() Rt®-XLSulfur Packed GC Column for Analysis of Low-Level Sulfur Compounds in C1-C6 Hydrocarbon StreamsRt®-XLSulfur columns resolve hydrocarbons from sulfur compounds in hydrocarbon process streams, and exhibit excellent inertness with low ppbv levels of sulfurs. |
![]() Improve Trace Analysis of Acetylene, Propadiene, and Methyl Acetylene Impurities With Higher Sample Capacity Alumina MAPD ColumnsRt®-Alumina BOND/MAPD columns offer higher capacity than other MAPD columns and are ideal for analyzing acetylene, propadiene, and methyl acetylene in petroleum gases. Greater capacity improves data accuracy due to better peak symmetry and a wide linear range. |
![]() Analysis of Trace Hydrocarbon Impurities in 1,3-Butadiene Using Optimized Rt®-Alumina BOND/MAPD PLOT ColumnsImpurity analysis of 1,3-butadiene on an Rt®-Alumina BOND/MAPD column results in good separation of both light polar impurities (methyl acetylene, propadiene) and 4-vinylcyclohexene, a heavier contaminant that often requires testing on a second column. |
![]() GCxGC Analysis of Complex Petroleum Hydrocarbons: Sulfur Speciation in DieselComprehensive 2D GC, also known as GCxGC, is a powerful technique with a great deal of potential for improving separations of complex petroleum and petrochemical samples that contain hundreds—or even thousands—of components. While GCxGC is still considered emerging technology and is used primarily in research and development labs, it has undergone significant growth in the past few years. |
![]() New Alumina Column Shows Promise for Analyzing ChlorofluorocarbonsRt®-Alumina BOND/CFC columns provide high retention and high selectivity for volatile halogenated hydrocarbons, without the activity that is usually observed with alumina adsorbents. Chlorofluorocarbon analysis, in particular, can benefit from this new technology. |
![]() Extending the Power of Stabilized PLOT Column Technology to Process GC AnalyzersNew metal MXT® PLOT columns offer greater stability than conventional PLOT columns, making them a better choice for process GC analyzer applications. New bonding techniques result in highly reproducible flow characteristics, improved layer stability, and excellent separation efficiencies. |
![]() Stable Sulfur & Mercury Sampling in Refineries Using Siltek® and Sulfinert® Surface Treated ComponentsRefinery and natural gas samples often contain trace amounts of sulfur- and mercury-containing compounds, which can interfere with reactions, poison catalysts in petrochemical processes, and damage equipment. Because these compounds quickly react with stainless steel surfaces, accurate determination of these compounds is impossible when samples are collected and stored in untreated sample cylinders. Restek's Siltek® and Sulfinert® passivation techniques bond an inert layer into the surface of stainless steel, preventing active compounds from reacting with or adsorbing to the steel. |
![]() How Much Sensitivity is Needed in a Leak Detector?Restek's Electronic Leak Detector is sensitive enough to find leaks below instrument pressure decay test levels and is available at a fraction of the cost of other hand-held units. |
![]() Faster DHA Analyses Using Helium or HydrogenRtx®-DHA columns are highly stable and can be run with helium or hydrogen under accelerated conditions. Restek has developed a new DHA method using Rtx®-DHA columns with hydrogen that can double refinery sample throughput. |
![]() Tighten Control of Distillation Processes with the New MXT®-1HT Sim Dist ColumnNew MXT®-1HT SimDist GC columns outperform competitors, allowing more productive D6352 analyses. Here we demonstrate lower bleed levels and higher efficiency, improving resolution and assuring more samples can be run within method specifications. |
Analyze Trace Polar Hydrocarbons More Accurately and Reliably With New Alumina BOND/MAPD PLOT Columns!Rt®- and MXT®-Alumina BOND/MAPD PLOT columns outperform other MAPD columns for trace analysis of methyl acetylene, acetylene, propadiene, and other polar hydrocarbons. The new deactivation results in more predictable responses, increased capacity, and higher temperature stability. (PDF - 1530kB) |
Biodiesel Solutions: Innovative Products for Simple, Reliable Biodiesel AnalysisThis flyer includes data demonstrating the performance of recommended GC columns for the analysis of total glycerin, fatty acid methyl esters (FAMEs), and residual methanol in biodiesel. Features a comparison of metal and fused silica columns. (PDF - 1652kB) |
ShinCarbon ST Micropacked GC Columns: Above-Ambient Analyses of Permanent Gases and Light HydrocarbonsA ShinCarbon ST micropacked column will separate hydrogen, oxygen, nitrogen, carbon dioxide, carbon monoxide, and methane in 10 minutes, without cryogenic cooling. This 2-page note also shows separations of light hydrocarbon/permanent gas mixtures, natural gas components, and fluorocarbons. (PDF - 228kB) |
Resolve Benzene and Toluene in Spark Ignition Fuels Containing EthanolThis 2-column set for modified ASTM Method D3606-10 completely resolves benzene from ethanol in reformulated fuels containing ethanol. The aromatic compounds also are fully separated and can easily be quantified using sec-butanol as an internal standard. (PDF - 1852kB) |
Detailed Hydrocarbon Analysis Featuring Rtx®-DHA ColumnsSuperior performance for DHA analysis! Rtx®-DHA columns offer 50% faster run times when used with hydrogen, improved resolution between oxygenates and hydrocarbons, and guaranteed column-to-column reproducibility. These columns also meet or exceed all ASTM and CAN/CGSB method guidelines. (PDF - 3922kB) |
Rt®-XLSulfur Packed Column: Specialized Packed and Micropacked Columns for Extra-Low Sulfur AnalysisRt®-XLSulfur packed and micropacked columns combine a unique, efficient porous polymer packing material and true inertness toward active analytes, to ensure excellent and reliable results in trace-level analyses of hydrogen sulfide, sulfur dioxide, and other lightweight sulfur compounds. (PDF - 370kB) |
Restek’s PLOT Column Family — The New Benchmark For Performance!Restek's PLOT column family is the new benchmark for performance! Our innovative bonding process minimizes particle release, reducing column blockage and protecting instrument parts. More consistent flow means stable retention times in Deans and related flow switching techniques.And outstanding peak symmetry improves impurity analysis for gases, solvents, and hydrocarbons. (PDF - 2463kB) |
Accurately Quantify Methanol and Ethanol in E85 Biofuel by D5501 with New Rtx®-DHA-150 ColumnImprove D5501 analysis of ethanol biofuel with Rtx®-DHA-150 columns. Reliably separate methanol and isobutane in just 20 minutes, with excellent symmetry for both target alcohols. (PDF - 1828kB) |
Increase Productivity: Get More Runs from Your SimDist Setup Using Next Generation MXT®-1HT SimDist ColumnsNew MXT®-1HT SimDist GC columns are shown to outperform competitors, allowing more productive D6352 analyses. Low bleed levels ensure accurate data and longer column lifetime. High efficiency improves resolution, assuring more samples can be run within method specifications. (PDF - 348kB) |
New Solutions for Your Petro AnalysesChromatograms, technical tips, and products developed specifically for petrochemical testing. Details recommendations for simulated distillation, PLOT column applications, DHA, D3606, biodiesel, permanent gases and hydrocarbons. (PDF - 1573kB) |
17 Minute D2712 Analysis of Impurities in Propylene Using PLOT ColumnsWhen analyzing hydrocarbon impurities in propylene by ASTM D2712, using an Rt®-Alumina BOND Na2SO4 PLOT column instead of a packed column setup provides the greatest degree of resolution in the least amount of time. (PDF - 121kB) |
GC Analysis of Petroleum ProductsMXT®-1 Sim Dist and MXT®-500 Sim Dist columns combine the inertness of fused silica with the durability of stainless steel, meeting all ASTM Method D6352 (petroleum simulated distillation) criteria. MXT®-500 Sim Dist columns have lower bleed and longer lifetimes, but calculated boiling points for aromatics are higher (closer to true values); MXT®-1 Sim Dist columns offer polarity that matches published data. Includes chromatograms. (PDF - 111kB) |
![]() |
![]() Hydrocarbons (C10-C100) on MXT®-1HT Sim DistGC_PC01120 |
![]() Detailed Hydrocarbons Analysis Rtx®-DHA-100GC_PC00743 |
![]() Refinery Gas on Rt®-Alumina BOND (Na2SO4)GC_PC01085 |
![]() Permanent Gases Rt®-Msieve 5AGC_PC00898 |