Pharmaceutical Solutions

Pharmaceutical Solutions

Pinnacle® DB HPLC & UHPLC Columns

  • Base deactivated silica—ideal for analysis of basic compounds or bases mixed with acids/neutrals.
  • Available phases: Biphenyl, C8, Cyano, Silica, Phenyl, PFP Propyl, PAH, IBD, C18, Aqueous C18.
  • 1.9 µm columns for UHPLC and 3 or 5 µm columns for standard HPLC.

Rxi® Capillary GC Columns

The ultimate high performance fused silica capillary column.

Certified Autosampler Vial Kits

Certified Vials, 2.0 mL Screw-Thread Vials

  • Certificates enclosed with each kit.
  • Vials of clear or amber borosilicate glass, with ID marking spots.
  • Closures with pre-inserted septa.
  • Each kit sealed for integrity.

Syringe Filters with Luer-Lok® Inlet

USP Residual Solvent Standards

  • USP equivalent standards for the revised USP <467> general chapter—compliance without the cost—compare prices today.
  • The only complete source for USP <467>.

Lamps

for Agilent HPLC Systems

Deuterium Lamp (Prealigned)

for Hitachi HPLC Systems

Lamps

for Thermo HPLC Systems

Xenon Lamps

for Waters Detectors

Deuterium Lamps

for Waters Detectors

LC/MS and GC/MS Analysis of Potential Genotoxic Impurities in Active Pharmaceutical Ingredients

Guidelines have recently been established for levels of potential genotoxic impurities (PGIs) in pharmaceutical APIs. This webinar outlines LC/MS and GC/MS methods developed in collaboration with Merck & Co.

Narrated by Amanda Rigdon, Innovations Chemist. Length: 17 minutes

The Analysis of Residual Solvents—Implementing USP <467>

Chromatographers implementing USP <467> Residual Solvents will benefit from this webinar which discusses system optimization and implementation strategies for USP <467>, as well as headspace GC fundamentals.

Narrated by Rick Lake, Pharmaceutical Market Development Manager.

Using Phenyl Column Chemistry to Optimize Reversed Phase Separations

Narrated by Rick Lake, Pharmaceutical Market Development Manager.

Troubleshooting the Acetonitrile Shortage—Strategies for Today and Tomorrow

Narrated by Rick Lake, Pharmaceutical Market Development Manager.

Technical Articles

General Interest

Optimize Selectivity & Efficiency in UHPLC Separations With More Stationary Phase Choices on 1.9 μm Pinnacle® DB HPLC Columns

Ultra-high pressure liquid chromatography (UHPLC) can significantly increase efficiency and produce faster separations. The small particle sizes used in UHPLC improve efficiency; however selectivity is still the most important factor affecting compound resolution. Here we demonstrate the importance of stationary phase choice in UHPLC separations. By optimizing selectivity for your analytes of interest, faster separations can be achieved without compromising resolution.

Clinical, Forensic & Toxicology

USLC™ Columns Put the Right Tools in Your LC Method Development Toolbox Understanding Selectivity in Reversed Phase Separations – A Simplified Approach to HPLC and UHPLC Column Selection

Column selectivity has the most significant influence on chromatographic peak separation, or resolution, so choosing the right column can greatly speed up HPLC and UHPLC method development. In this article, we discuss column choice and identify a set of just 4 stationary phases—Restek’s USLC™ column set—that encompasses the widest range of reversed phase selectivity available today.

Pharmaceutical

Two Options for Analyzing Potential Genotoxic Impurities in Active Pharmaceutical Ingredients

Two options for the analysis of PGIs in API have been developed by Merck and Restek to meet different laboratory needs. The first option is a fast method for the analysis of sulfonate esters on the Rxi®-5Sil MS column. The second option is a comprehensive method for the analysis of both sulfonate esters and alkyl halides on the Rtx®-200 column. Both methods require very little sample preparation, which helps increase laboratory productivity.

General Interest

Pesticides in Dietary Supplements: Advantages of QuEChERS vs. PAM 303

Restek has developed the first QuEChERS-based method for determining pesticide residues in dietary supplements. This simple, cost-effective procedure reduces matrix interferences as well as sample prep variation among technicians.

Pharmaceutical

Explaining the Small Particle Advantage Faster Sample Throughput on a 1.9µm Pinnacle™ DB Column

Small particle HPLC columns can offer faster analysis times but only if the particle size distribution is tightly controlled. Restek’s 1.9µm Pinnacle™ DB columns have tight, symmetric particle size distributions and contain no particles less than 1µm. Here we demonstrate how our stringent quality requirements translate into faster, more reproducible results compared to competitor columns. Greater column efficiency and reproducibility mean faster throughput and more consistent results.

PDF Document

Determining Pesticides in Dietary Supplements with QuEChERS Extraction, Cartridge SPE, and GCxGC-TOFMS

The novel approach used here combines QuEChERS extraction, cartridge SPE cleanup, and GCxGC-TOFMS analysis, resulting in good recoveries for a wide range of pesticides in dietary supplements. Matrices include dandelion root, sage, and a multi-herb finished product. (PDF - 394kB)

PDF Document

Simplify Sample Prep and Protect Analytical Equipment With Syringe Filters

Filtering sample extracts with syringe filters will greatly extend the life of costly chromatographic columns and replacement parts, particularly for HPLC systems. This 2-page fact sheet includes helpful membrane, porosity, and size selection guides. (PDF - 119kB)

PDF Document

USLC™ Columns: Choose Columns Fast. Develop Methods Faster.

Restek USLC™ columns offer the widest range of selectivity available and are an integral part of successful method development. Ideal for column switching systems, these columns provide orthogonal separations to create optimal resolution and robust methods—all in a 4-column set. (PDF - 1813kB)

PDF Document

USLC™ Column Selection & Mobile Phase Adjustment Guide

USLC™ columns and this guide will help you easily choose the right stationary phase to target nearly any analyte in reversed phase or HILIC method development. It will also help you adjust your mobile phase to further improve results without guesswork or wasted time. (PDF - 1682kB)

PDF Document

USLC™ Method Development Toolbox: All the Right Tools—All in One Box

Restek’s USLC™ column set represents an incredible range of reversed phase selectivity with just 4 stationary phases: Aqueous C18, IBD, Biphenyl, and PFP Propyl. It simplifies column choice for fast, effective method development—and new USLC™ toolboxes make things even easier! (PDF - 681kB)

PDF Document

Rxi®-624Sil MS Columns—Exceptionally Inert, Low Bleed Columns for Volatiles Analysis

Analyze volatile compounds and polar analytes with greater confidence using Rxi®-624Sil MS columns. Optimized selectivity, higher inertness, and lower bleed result in reliable separations and accurate, trace-level determinations. Includes environmental and pharmaceutical applications. (PDF - 3111kB)

PDF Document

Custom Residual Solvents Mixes

Save time and money—let Restek custom blend reference standards specifically for your residual solvent testing needs! (PDF - 76kB)

PDF Document

Biphenyl: Next Generation of Phenyl Columns

Biphenyl columns provide both high hydrophobic retention and aromatic selectivity in the same column. Orthogonal separations can be achieved with simple mobile phase changes, giving markedly better separations for a wide variety of molecules. (PDF - 531kB)

PDF Document

Residual Solvent Analysis: Implementing USP <467>

This 12-page reference includes a review of headspace fundamentals, the revised USP <467> method (July, 2008), chromatography for Procedures A, B, and C, and technical tips for optimization. Guidance on fast, effect method development is given. (PDF - 471kB)

PDF Document

Rxi®-624Sil MS

Develop impurity methods faster and more efficiently using a single column that combines the selectivity of a 624 with the thermal stability of a 1 or 5 type column. The new Rxi®-624Sil MS column offers good retention of polar compounds, mass spec compatibility, and unsurpassed inertness, making it the most broadly applicable GC column available to the pharmaceutical industry. (PDF - 1058kB)