Welcome, Guest  -  Log In |  Register  |  Shopping Cart
< Reference Standards < 8000 Series | Solid Waste | Herbicides

Uniliner® Liners for 1/4-Inch Packed Injection Port Conversion

5mm Uniliner® liners fit into the 1/4-inch Uniliner® Liner Adaptor, which fits into a 1/4-inch injection port. The Uniliner® liner can be inserted in one direction for direct injections or inverted for on-column injections. Because the 1/4-inch injection port ferrule seals against the metal liner adaptor surface, it is virtually impossible to crack the glass Uniliner® liner during installation.


On-column injections can be performed only with 0.53mm ID columns because
26-gauge needles do not fit into the bore of 0.32mm ID columns, or into the Unliner® liner taper.

for 1/4-Inch Packed Injection Port Conversion

Instruction Sheets:

203-02-002.pdf
205-07-002.pdf
205-08-001.pdf
  Description Instrument Fits Col. ID Includes qty. Cat.# Price     Wish
list
Cart 
 Uniliner® Liner
  Uniliner Liner (small buffer volume chamber 60mm long, for injections <=2µL)  0.53mm
DI or OC
  ea.20902
  Uniliner Liner (small buffer volume chamber- 60mm long, for injections <=2µL)  0.53mm
DI or OC
  5-pk.20903
  Uniliner Liner (large buffer volume chamber 85mm long, for injections <=4µL)  0.32 & 0.53mm
DI only
  ea.20308
  Uniliner Liner (large buffer volume chamber- 85mm long, for injections <=4µL)  0.32 & 0.53mm
DI only
  5-pk.20309
  Uniliner Liner (large buffer volume chamber- 85mm long, for injections <=4µL)  0.53mm
DI or OC
  ea.20301
  Uniliner Liner (large buffer volume chamber- 85mm long, for injections <=4µL)  0.53mm
DI or OC
  5-pk.20305
 Cyclo-Uniliner® Liner
  Cyclo-Uniliner Liner (for active, dirty samples)  0.32 & 0.53mm
DI only
  ea.20319
  Cyclo-Uniliner Liner (for active, dirty samples)  0.32 & 0.53mm
DI only
  5-pk.20320
 Open-Top Uniliner® Liner
  Open-Top Uniliner Liner (packed with wool)  0.32 & 0.53mm
DI only
  ea.20315
  Open-Top Uniliner Liner (packed with wool)  0.32 & 0.53mm
DI only
  5-pk.20316
 Low Volume/Purge & Trap Uniliner® Liner
  Low Volume/Purge & Trap Uniliner Liner (1mm ID x 5mm OD: use in 1/4" injection ports to troubleshoot purge & trap units)  0.32 & 0.53mm
DI only
  ea.20307
  Low Volume/Purge & Trap Uniliner Liner (1mm ID x 5mm OD: use in 1/4" injection ports to troubleshoot purge & trap units)  0.32 & 0.53mm
DI only
  5-pk.20314
 Liner Adaptors, Fittings, & Ferrules
  Uniliner Liner Adaptor for injection ports <8cm (required for installing Uniliner liners in 1/4" injection ports)   Includes 1/4-inch stainless steel nut & graphite ferrule, 1/16-inch stainless steel nut, and 0.8mm ID graphite ferrule. ea.20310
  Siltek Treated Uniliner Liner Adaptor for injection ports <8cm (required for installing Uniliner liners in 1/4" injection ports)   Includes 1/4-inch Siltek treated nut & graphite ferrule, 1/16-inch Siltek treated nut, and 0.8mm ID graphite ferrule. ea.22282
  Uniliner Liner Adaptor for injection ports 8-15cm (required for installing Uniliner liners in 1/4" injection ports)   Includes 1/4-inch stainless steel nut & graphite ferrule, 1/16-inch stainless steel nut, and 0.8mm ID graphite ferrule. ea.20311
  5mm Stainless Steel Uniliner Liner Adaptor Fitting for Shimadzu Packed Column GCs   ea.20312
  1/4" Ferrules for Uniliner Liner Adaptor    5-pk.20234
*DI = direct injection, OC = on-column injection

Note: a Uniliner liner must be used with a Uniliner Liner Adaptor (cat.# 20310 or 20311) for 1/4-inch injection ports. Remember to include a liner adaptor when ordering a Uniliner liner, unless you are purchasing replacement Uniliner liners.
Click thumbnails to see enlarged view.

20902
Uniliner® Liner 0.53mm Column ID, 60mm long IP Deact., ea

20312
Shimadzu Adapter, 5mm-1/16" SS
   
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)