Ultra Aqueous C18 3µm & 5µm Columns (USP L1)



Highly retentive and selective for reversed phase separations of polar analytes. Highly base-deactivated. Compatible with highly aqueous (up to 100%) mobile phases.


particle size: 3µm or 5µm, spherical
pore size: 100Å
carbon load: 15%
endcap: no
pH range: 2.5 to 7.5
temperature limit: 80°C

Ultra Aqueous C18 (USP L1) is the ideal column for analyses that require >90% water in the mobile phase. Excellent phase for high water solubility or low organic solubility compounds. Excellent for water soluble vitamins and organic acids.

Instruction Sheets:

700-02-001.pdf
  Description Length Pore Size (Å) Modification ID qty. Cat.# Price     Wish
list
Cart 
 3µm
  Ultra Aqueous C18 Capillary Column 50mm 100  0.3mm ea.917835B
  Ultra Aqueous C18 Capillary Column 150mm 100  0.3mm ea.917836B
  Ultra Aqueous C18 30mm 100  1.0mm ea.9178331
  Ultra Aqueous C18 50mm 100  1.0mm ea.9178351
  Ultra Aqueous C18 100mm 100  1.0mm ea.9178311
  Ultra Aqueous C18 30mm 100  2.1mm ea.9178332
  Ultra Aqueous C18 50mm 100  2.1mm ea.9178352
  Ultra Aqueous C18 100mm 100  2.1mm ea.9178312
  Ultra Aqueous C18 30mm 100  3.2mm ea.9178333
  Ultra Aqueous C18 50mm 100  3.2mm ea.9178353
  Ultra Aqueous C18 100mm 100  3.2mm ea.9178313
  Ultra Aqueous C18 30mm 100  4.6mm ea.9178335
  Ultra Aqueous C18 50mm 100  4.6mm ea.9178355
  Ultra Aqueous C18 100mm 100  4.6mm ea.9178315
  Ultra Aqueous C18 30mm 100 with Trident Inlet Fitting 2.1mm ea.9178332-700
  Ultra Aqueous C18 50mm 100 with Trident Inlet Fitting 2.1mm ea.9178352-700
  Ultra Aqueous C18 100mm 100 with Trident Inlet Fitting 2.1mm ea.9178312-700
  Ultra Aqueous C18 30mm 100 with Trident Inlet Fitting 3.2mm ea.9178333-700
  Ultra Aqueous C18 50mm 100 with Trident Inlet Fitting 3.2mm ea.9178353-700
  Ultra Aqueous C18 100mm 100 with Trident Inlet Fitting 3.2mm ea.9178313-700
  Ultra Aqueous C18 30mm 100 with Trident Inlet Fitting 4.6mm ea.9178335-700
  Ultra Aqueous C18 50mm 100 with Trident Inlet Fitting 4.6mm ea.9178355-700
  Ultra Aqueous C18 100mm 100 with Trident Inlet Fitting 4.6mm ea.9178315-700
 5µm
  Ultra Aqueous C18 30mm 100  1.0mm ea.9178531
  Ultra Aqueous C18 50mm 100  1.0mm ea.9178551
  Ultra Aqueous C18 100mm 100  1.0mm ea.9178511
  Ultra Aqueous C18 150mm 100  1.0mm ea.9178561
  Ultra Aqueous C18 200mm 100  1.0mm ea.9178521
  Ultra Aqueous C18 250mm 100  1.0mm ea.9178571
  Ultra Aqueous C18 30mm 100  2.1mm ea.9178532
  Ultra Aqueous C18 50mm 100  2.1mm ea.9178552
  Ultra Aqueous C18 100mm 100  2.1mm ea.9178512
  Ultra Aqueous C18 150mm 100  2.1mm ea.9178562
  Ultra Aqueous C18 200mm 100  2.1mm ea.9178522
  Ultra Aqueous C18 250mm 100  2.1mm ea.9178572
  Ultra Aqueous C18 30mm 100  3.2mm ea.9178533
  Ultra Aqueous C18 50mm 100  3.2mm ea.9178553
  Ultra Aqueous C18 100mm 100  3.2mm ea.9178513
  Ultra Aqueous C18 150mm 100  3.2mm ea.9178563
  Ultra Aqueous C18 200mm 100  3.2mm ea.9178523
  Ultra Aqueous C18 250mm 100  3.2mm ea.9178573
  Ultra Aqueous C18 30mm 100  4.6mm ea.9178535
  Ultra Aqueous C18 50mm 100  4.6mm ea.9178555
  Ultra Aqueous C18 100mm 100  4.6mm ea.9178515
  Ultra Aqueous C18 150mm 100  4.6mm ea.9178565
  Ultra Aqueous C18 200mm 100  4.6mm ea.9178525
  Ultra Aqueous C18 250mm 100  4.6mm ea.9178575
  Ultra Aqueous C18 30mm 100 with Trident Inlet Fitting 2.1mm ea.9178532-700
  Ultra Aqueous C18 50mm 100 with Trident Inlet Fitting 2.1mm ea.9178552-700
  Ultra Aqueous C18 100mm 100 with Trident Inlet Fitting 2.1mm ea.9178512-700
  Ultra Aqueous C18 150mm 100 with Trident Inlet Fitting 2.1mm ea.9178562-700
  Ultra Aqueous C18 200mm 100 with Trident Inlet Fitting 2.1mm ea.9178522-700
  Ultra Aqueous C18 250mm 100 with Trident Inlet Fitting 2.1mm ea.9178572-700
  Ultra Aqueous C18 30mm 100 with Trident Inlet Fitting 3.2mm ea.9178533-700
  Ultra Aqueous C18 50mm 100 with Trident Inlet Fitting 3.2mm ea.9178553-700
  Ultra Aqueous C18 100mm 100 with Trident Inlet Fitting 3.2mm ea.9178513-700
  Ultra Aqueous C18 150mm 100 with Trident Inlet Fitting 3.2mm ea.9178563-700
  Ultra Aqueous C18 200mm 100 with Trident Inlet Fitting 3.2mm ea.9178523-700
  Ultra Aqueous C18 250mm 100 with Trident Inlet Fitting 3.2mm ea.9178573-700
  Ultra Aqueous C18 30mm 100 with Trident Inlet Fitting 4.6mm ea.9178535-700
  Ultra Aqueous C18 50mm 100 with Trident Inlet Fitting 4.6mm ea.9178555-700
  Ultra Aqueous C18 100mm 100 with Trident Inlet Fitting 4.6mm ea.9178515-700
  Ultra Aqueous C18 150mm 100 with Trident Inlet Fitting 4.6mm ea.9178565-700
  Ultra Aqueous C18 200mm 100 with Trident Inlet Fitting 4.6mm ea.9178525-700
  Ultra Aqueous C18 250mm 100 with Trident Inlet Fitting 4.6mm ea.9178575-700
     
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)