Columns for Hydrophobic Neutral Analytes
TO-15 65 Component Mix
Now updated to include naphthalene!
Our high-quality air monitoring gas calibration standards are provided by Spectra Gases and Scott Specialty Gases--meeting lab requirements for two separate sources of calibration standards. Mixes are produced gravimetrically using NIST (National Institute of Science and Technology) traceable weights. Each comes with a Certificate of Analysis and unique serial number. All cylinders are disposable and do not require rental or demurrage fees. Recertification of cylinders is available directly with our suppliers. All cylinders are drop-shipped from our suppliers to provide fast delivery and the "freshest" standard possible. 12-month stability on all cylinders unless otherwise specified.
Spectra 104L Cylinders:
Aluminum construction
Size: 8 x 24 cm.
Volume/Pressure: 104 liters of gas @ 1,800psi
CGA-180 outlet fitting.
Weight: 1.5 lbs./0.7 kg
Scotty 110L Cylinders (PI-marked Cylinders for EU Regulations):
Aluminum construction
Size: 8.3 x 29.5 cm.
Volume/Pressure: 110 liters of gas @ 1,800psi
CGA-180 outlet fitting.
Weight: 2.2 lbs/1 kg
US DOT Specs: 3AL2216
acetone
acrolein
benzene
benzyl chloride*
bromodichloromethane
bromoform
bromomethane
1,3-butadiene
2-butanone (MEK)
carbon disulfide*
carbon tetrachloride
chlorobenzene
chloroethane
chloroform
chloromethane
cyclohexane
dibromochloromethane
1,2-dichlorobenzene
1,3-dichlorobenzene
1,4-dichlorobenzene
1,1-dichloroethane
1,2-dichloroethane
1,1-dichloroethene
cis-1,2-dichloroethene
trans-1,2-dichloroethene
1,2-dichloropropane
cis-1,3-dichloropropene
trans-1,3-dichloropropene
1,4-dioxane
ethanol*
ethyl acetate
ethyl benzene
ethylene dibromide (1,2-dibromoethane)
4-ethyltoluene
trichlorofluoromethane (Freon 11)
dichlorodifluoromethane (Freon 12 )
1,1,2-trichloro-1,2,2-trifluoroethane (Freon 113)
1,2-dichlorotetrafluoroethane (Freon 114)
heptane
hexachloro-1,3-butadiene
hexane
2-hexanone (MBK)
4-methyl-2-pentanone (MIBK)
methylene chloride
methyl
tert-butyl ether (MTBE)
methyl methacrylate
naphthalene
2-propanol
propylene
styrene
1,1,2,2-tetrachloroethane
tetrachloroethene
tetrahydrofuran
toluene
1,2,4-trichlorobenzene
1,1,1-trichloroethane
1,1,2-trichloroethane
trichloroethene
1,2,4-trimethylbenzene
1,3,5-trimethylbenzene
vinyl acetate
vinyl chloride
m-xylene
o-xylene
p-xylene
Gas standards are subject to hazardous materials shipping fees by most freight carriers.
All calibration gas standards are nonreturnable due to DOT hazardous shipping requirements.
*Stability of this compound cannot be guaranteed.
No data pack available.
Quantity discounts not available.