Hydroguard® Fused Silica Guard/Retention Gap Columns & Transfer Lines

Use guard columns to:•Reduce effects of dirty samples on column performance.•Reduce downtime and maintenance.

• Extend analytical column lifetime by preventing degradation by harsh “steam-cleaning” water injections.
• Maximum temperature: 430°C.
When transfer lines from purge & trap systems, air monitoring equipment, or other instruments carry condensed water vapor, deactivated column tubing quickly becomes active because of the creation of free silanol groups. These silanol groups adsorb active oxygenated compounds such as alcohols and diols.
Restek chemists have addressed this concern and found a solution--the Hydroguard® deactivation process. A unique deactivation chemistry creates a high-density surface that is not readily attacked by aggressive hydrolysis. The high-density surface coverage of the Hydroguard® deactivation layer effectively prevents water vapor from reaching the fused silica surface beneath. Use Hydroguard® tubing for connecting GCs to:
• Purge & trap systems.
• Headspace analyzers.
• Air analysis equipment and concentrator units.
  Description Length OD qty. Cat.# Price     Wish
list
Cart 
 0.05mm*
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.363 ± 0.012mm ea.10075
 0.10mm*
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.363 ± 0.012mm ea.10076
 0.15mm
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.363 ± 0.012mm ea.10077
 0.18mm
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.37 ± 0.04mm ea.10078
 0.25mm
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.37 ± 0.04mm ea.10079
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.37 ± 0.04mm 6-pk.10079-600
  Hydroguard Fused Silica Guard Columns & Transfer Lines 10-Meter 0.37 ± 0.04mm ea.10082
  Hydroguard Fused Silica Guard Columns & Transfer Lines 30-Meter** 0.37 ± 0.04mm ea.10085
  Hydroguard Fused Silica Guard Columns & Transfer Lines 60-Meter**† 0.37 ± 0.04mm ea.10088
 0.32mm
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.45 ± 0.04mm ea.10080
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.45 ± 0.04mm 6-pk.10080-600
  Hydroguard Fused Silica Guard Columns & Transfer Lines 10-Meter 0.45 ± 0.04mm ea.10083
  Hydroguard Fused Silica Guard Columns & Transfer Lines 30-Meter** 0.45 ± 0.04mm ea.10086
  Hydroguard Fused Silica Guard Columns & Transfer Lines 60-Meter**† 0.45 ± 0.04mm ea.10089
 0.53mm
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.69 ± 0.05mm ea.10081
  Hydroguard Fused Silica Guard Columns & Transfer Lines 5-Meter 0.69 ± 0.05mm 6-pk.10081-600
  Hydroguard Fused Silica Guard Columns & Transfer Lines 10-Meter 0.69 ± 0.05mm ea.10084
  Hydroguard Fused Silica Guard Columns & Transfer Lines 10-Meter 0.69 ± 0.05mm 6-pk.10084-600
  Hydroguard Fused Silica Guard Columns & Transfer Lines 30-Meter** 0.69 ± 0.05mm ea.10087
  Hydroguard Fused Silica Guard Columns & Transfer Lines 60-Meter**† 0.69 ± 0.05mm ea.10090
*Not tested with the Grob test mix because of a large pressure drop.
**30- and 60-meter lengths are banded in 5-meter sections.
†Recommendation: Cut 60m guard columns into shorter lengths. Using full length may cause peak distortion.
     
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)