Welcome, Guest  -  Log In |  Register  |  Shopping Cart
< Air Monitoring & Gas Sampling < Thermal Desorption Unit Tubes

Innovative Integra-Guard® Columns



For analysts who find it inconvenient to make a leak-free connection between the guard column and the analytical column, we offer Integra-Guard® columns. These innovative columns incorporate both guard column and analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems! The guard column section is marked separately from the analytical column, using high-temperature string.
A wide variety of our Integra-Guard® capillary columns are listed below. The Integra-Guard® column is so economical that we challenge you to compare our price against that of a conventional connection, even if you assemble it yourself. If you are currently using a guard column, or are considering using one, call today and ask about Integra-Guard® columns.

Get the protection without the connection!

Instruction Sheets:

100-00-001.pdf
  Description Length temp. limits Modification qty. Cat.# Price     Wish
list
Cart 
 0.25mm
 0.25µm df
  Rtx-1 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.10123-124
 0.53mm
 1.00µm df
  Rtx-1 30-Meter -60 to 310/330°C w/5m Integra-Guard Column ea.10155-126
 5.00µm df
  Rtx-1 30-Meter -60 to 270/290°C w/5m Integra-Guard Column ea.10179-126
 0.25mm
 0.25µm df
  Rtx-5 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.10223-124
  Rtx-5 30-Meter -60 to 330/350°C w/10m Integra-Guard Column ea.10223-127
 1.00µm df
  Rtx-5 30-Meter -60 to 320/340°C w/5m Integra-Guard Column ea.10253-124
 0.32mm
 0.25µm df
  Rtx-5 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.10224-125
  Rtx-5 60-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.10227-125
 1.00µm df
  Rtx-5 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.10254-125
 0.53mm
 5.00µm df
  Rtx-5 30-Meter -60 to 270/290°C w/5m Integra-Guard Column ea.10279-126
 0.25mm
 0.25µm df
  Rtx-5MS 15-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.12620-124
 0.50µm df
  Rtx-5MS 15-Meter -60 to 330/350°C w/10m Integra-Guard Column ea.12635-127
 0.10µm df
  Rtx-5MS 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.12608-124
 0.25µm df
  Rtx-5MS 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.12623-124
  Rtx-5MS 30-Meter -60 to 330/350°C w/10m Integra-Guard Column ea.12623-127
 0.50µm df
  Rtx-5MS 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.12638-124
  Rtx-5MS 30-Meter -60 to 330/350°C w/10m Integra-Guard Column ea.12638-127
 0.32mm
 0.25µm df
  Rtx-5MS 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.12624-125
 1.00µm df
  Rtx-5MS 30-Meter -60 to 325/350°C w/5m Integra-Guard Column ea.12654-125
 0.25mm
 0.25µm df
  Rxi-5Sil MS 15-Meter -60 to 330/350°C w/10m Integra-Guard Column ea.13620-127
  Rxi-5Sil MS 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.13623-124
  Rxi-5Sil MS 30-Meter -60 to 330/350°C w/10m Integra-Guard Column ea.13623-127
 0.50µm df
  Rxi-5Sil MS 15-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.13635-124
  Rxi-5Sil MS 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.13638-124
  Rxi-5Sil MS 30-Meter -60 to 330/350°C w/10m Integra-Guard Column ea.13638-127
 0.32mm
 0.50µm df
  Rxi-5Sil MS 30-Meter -60 to 330/350°C w/5m Integra-Guard Column ea.13639-125
 1.00µm df
  Rxi-5Sil MS 30-Meter -60 to 325/350°C w/5m Integra-Guard Column ea.13654-125
 0.25mm
 1.40µm df
  Rtx-624 30-Meter -20 to 240°C w/5m Integra-Guard Column ea.10968-124
 0.32mm
 1.80µm df
  Rtx-624 30-Meter -20 to 240°C w/5m Integra-Guard Column ea.10970-125
 0.53mm
 3.00µm df
  Rtx-624 30-Meter -20 to 240°C w/5m Integra-Guard Column ea.10971-126
  Rtx-1301 30-Meter -20 to 240°C w/5m Integra-Guard Column ea.16085-126
 0.25mm
 0.25µm df
  Rtx-1701 30-Meter -20 to 280°C w/5m Integra-Guard Column ea.12023-124
  Stabilwax 30-Meter 40 to 250°C w/5m Integra-Guard Column ea.10623-124
 0.32mm
 1.00µm df
  Stabilwax 30-Meter 40 to 240/250°C w/5m Integra-Guard Column ea.10654-125
 0.53mm
 1.00µm df
  Stabilwax 30-Meter 40 to 240/250°C w/5m Integra-Guard Column ea.10655-126
 0.32mm
 1.80µm df
  Rtx-BAC1 30-Meter -20 to 240/260°C w/5m Integra-Guard Column ea.18003-125
 1.20µm df
  Rtx-BAC2 30-Meter -20 to 240/260°C w/5m Integra-Guard Column ea.18002-125
 0.53mm
 3.00µm df
  Rtx-BAC1 30-Meter -20 to 240/260°C w/5m Integra-Guard Column ea.18001-126
Rtx®-1
Rtx®-5
Rtx®-5MS
Rxi®-5Sil MS
Rtx®-1301
Rtx®-624
Rtx®-1701
Rtx®-Volatiles
Rtx®-20
Rtx®-35
Rtx®-BAC 1 & 2
Stabilwax®
Integra-Guard® columns are available for all phases listed, for columns with 0.25, 0.32 or 0.53mm ID.
If you don’t see what you need here, contact us.
     
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)