Welcome, Guest  -  Log In |  Register  |  Shopping Cart
< HPLC Columns < Columns for Mixed Analytes

EZ No-Vent® GC Column-MS Connector for Varian




Restek has designed the EZ No-Vent® GC column-mass spectrometer connector to be simple and easy to use. A critical orifice in the EZ No-Vent® connector minimizes the amount of oxygen allowed into the MS source, eliminating the need for purge gas as is required for other manufacturer's vent systems. The lengthy vent and pump-down cycle is not required, and normal instrument down-time from a column change is dramatically reduced. The EZ No-Vent® connector easily attaches to the MS source without special tools or extra plumbing.

for Varian Saturn 2000 Series MSs

Instruction Sheets:

203-02-018.pdf
  Description Material Instrument Size Vendor Tubing ID Tubing OD Includes qty. Cat.# Price     Wish
list
Cart 
  EZ No-Vent Connector Kit  for Varian Saturn 2000 Series MSs     includes: EZ No-Vent Connector, two 0.4mm ID adaptor ferrules for capillary column, two 0.4mm ID ferrules for transfer line, 100µm deactivated transfer line (3 ft.), column plug, column nut kit22423
  Adaptor Ferrule Polyimide  1/16" Valco 0.4mm ID 0.25--0.4mm  2-pk.21015
  Adaptor Ferrule Polyimide  1/16" Valco 0.5mm ID 0.4--0.5mm  2-pk.21016
  Replacement ferrules for connecting transfer line to EZ No-Vent Connector: 0.4mm ID Polyimide       2-pk.21043
  Replacement 100µm deactivated transfer line        3 ft.21018
  Nut Stainless Steel  1/16" Parker    5-pk.21900
  Plug Stainless Steel  1/16" Parker    2-pk.21915
  Open-End Wrenches   1/4" x 5/16"     2-pk.20110
Click thumbnails to see enlarged view.

22423
EZ No-Vent® for Varian Saturn 2000 Series MS

21015
EZ No-Vent® Ferrules, Replacement 1/16" polyimide adaptor ferrules 0.4mm ID: Pack of 2

21900
Fitting, Stainless Steel, 1/16" Nut Pack of 5

21915
Fitting, Stainless Steel, 1/16" Plug Pack of 2

20110
Tool, Wrench, 1/4" X 5/16" Open End, 2 Pack
   
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)