Air Monitoring Canisters: TO-Can®
- Proprietary electropolished surface that maintains compound stability.
- High quality, metal-to-metal seal, 2/3-turn valve with stainless steel diaphragms.
- 2-port or 3-port valve available; 3-port valve includes -30" Hg/60psi vacuum/pressure gauge (other gauges available).
| Features | Benefits |
| Metal to metal seat, valve with stainless steel diaphragms. |
No sample adsorption, for more accurate results. |
| Vacuum/pressure gauge (optional). |
Ascertain internal conditions at a glance. |
| Variety of sizes. |
Meet a range of sampling needs. |
| Stable to 250°C. |
Heat canister to 250°C for superior cleaning. |
|
US EPA Compendium of Air Methods TO-14A and TO-15 regulate the collection, storage, and analysis of volatile organic compounds (VOCs) using treated air sampling canisters. Restek offers a complete line of TO-Can® canisters (SUMMA can equivalent), electropolished using a proprietary process and extensively cleaned using an ultrasonic method. This ensures a high-quality, passivated surface that maintains the stability of TO-14A/TO-15 compounds during storage. The frame surrounds the electropolished canister, eliminating the need for weld marks on the sphere, thereby preventing active sites on the canister. The Parker Hannifin metal-to-metal diaphragm valve supports the excellent performance of the canister.
The unique holder attaches the handle and base to the canister without welds, and protects the canister, tube stub, and valve. The 2/3-turn diaphragm valve has a metal-to-metal seat and a temperature limit of 250°C. We leak check the system with helium to ensure the TO-Can® canister and valve are leak-tight, then pressurize the canister with contaminant-free nitrogen before we ship it.
Optimized for US EPA Methods TO-14A and TO-15, and ASTM D5466
- SUMMA canister equivalent.
- Excellent analyte recovery--even after 14 days of storage.
Instruction Sheets:
Restek canisters are originally equipped with high-quality Parker Hannifin diaphragm valves. Each valve is helium leak-tested to 4 x 10
-9cc/sec. The all-stainless steel construction eliminates contamination and withstands temperatures from -100°C to 250°C. Other features include a compression outlet fitting and a 1/4" inlet and outlet.
*If attaching any of Restek's passive sampling kits to a 3L canister, use a Siltek treated (cat.# 563646) or stainless steel (cat.# 563647) connector between the two components.
Click thumbnails to see enlarged view.
24173 TO-Can® Canister, 3 Liter, 1/4" Valve
|
24177 TO-Can® Canister, 3 Liter, 1/4" Valve with Gauge
|
|
|