Viva PFP Propyl 5µm Columns (USP L43)



Viva columns are based on a wide pore material we designed for optimal large molecule separations. In developing Viva silica, we found that although many commercial wide-pore silicas meet the standard 300Å mean pore size, most have very broad distributions about this mean, with a significant portion of their pore volume falling below 150Å. This means a large portion of the surface area is unavailable to larger molecules. Viva columns have a narrow distribution about the mean pore size, permitting a larger portion of the silica surface to play a role in the separation.


A pentafluorophenyl phase with a propyl spacer. Highly retentive for basic analytes. Highly base-deactivated wide pore packing that exhibits excellent peak shape for a wide range of compounds, including nucleosides, nucleotides, and halogenated compounds.


particle size: 5µm, spherical
pore size: 300Å
carbon load: 5%
endcap: yes
pH range: 2.5 to 7.5
temperature limit: 80°C
  Description Length Pore Size (Å) Modification ID qty. Cat.# Price     Wish
list
Cart 
 5µm
  Viva PFP Propyl 30mm 300  1.0mm ea.9519531
  Viva PFP Propyl 50mm 300  1.0mm ea.9519551
  Viva PFP Propyl 100mm 300  1.0mm ea.9519511
  Viva PFP Propyl 150mm 300  1.0mm ea.9519561
  Viva PFP Propyl 200mm 300  1.0mm ea.9519521
  Viva PFP Propyl 250mm 300  1.0mm ea.9519571
  Viva PFP Propyl 30mm 300  2.1mm ea.9519532
  Viva PFP Propyl 50mm 300  2.1mm ea.9519552
  Viva PFP Propyl 100mm 300  2.1mm ea.9519512
  Viva PFP Propyl 150mm 300  2.1mm ea.9519562
  Viva PFP Propyl 200mm 300  2.1mm ea.9519522
  Viva PFP Propyl 250mm 300  2.1mm ea.9519572
  Viva PFP Propyl 30mm 300  3.2mm ea.9519533
  Viva PFP Propyl 50mm 300  3.2mm ea.9519553
  Viva PFP Propyl 100mm 300  3.2mm ea.9519513
  Viva PFP Propyl 150mm 300  3.2mm ea.9519563
  Viva PFP Propyl 200mm 300  3.2mm ea.9519523
  Viva PFP Propyl 250mm 300  3.2mm ea.9519573
  Viva PFP Propyl 30mm 300  4.6mm ea.9519535
  Viva PFP Propyl 50mm 300  4.6mm ea.9519555
  Viva PFP Propyl 100mm 300  4.6mm ea.9519515
  Viva PFP Propyl 150mm 300  4.6mm ea.9519565
  Viva PFP Propyl 200mm 300  4.6mm ea.9519525
  Viva PFP Propyl 250mm 300  4.6mm ea.9519575
  Viva PFP Propyl 30mm 300 with Trident Inlet Fitting 2.1mm ea.9519532-700
  Viva PFP Propyl 50mm 300 with Trident Inlet Fitting 2.1mm ea.9519552-700
  Viva PFP Propyl 100mm 300 with Trident Inlet Fitting 2.1mm ea.9519512-700
  Viva PFP Propyl 150mm 300 with Trident Inlet Fitting 2.1mm ea.9519562-700
  Viva PFP Propyl 200mm 300 with Trident Inlet Fitting 2.1mm ea.9519522-700
  Viva PFP Propyl 250mm 300 with Trident Inlet Fitting 2.1mm ea.9519572-700
  Viva PFP Propyl 30mm 300 with Trident Inlet Fitting 3.2mm ea.9519533-700
  Viva PFP Propyl 50mm 300 with Trident Inlet Fitting 3.2mm ea.9519553-700
  Viva PFP Propyl 100mm 300 with Trident Inlet Fitting 3.2mm ea.9519513-700
  Viva PFP Propyl 150mm 300 with Trident Inlet Fitting 3.2mm ea.9519563-700
  Viva PFP Propyl 200mm 300 with Trident Inlet Fitting 3.2mm ea.9519523-700
  Viva PFP Propyl 250mm 300 with Trident Inlet Fitting 3.2mm ea.9519573-700
  Viva PFP Propyl 30mm 300 with Trident Inlet Fitting 4.6mm ea.9519535-700
  Viva PFP Propyl 50mm 300 with Trident Inlet Fitting 4.6mm ea.9519555-700
  Viva PFP Propyl 100mm 300 with Trident Inlet Fitting 4.6mm ea.9519515-700
  Viva PFP Propyl 150mm 300 with Trident Inlet Fitting 4.6mm ea.9519565-700
  Viva PFP Propyl 200mm 300 with Trident Inlet Fitting 4.6mm ea.9519525-700
  Viva PFP Propyl 250mm 300 with Trident Inlet Fitting 4.6mm ea.9519575-700
     
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)