DI Liners for Shimadzu 17A, 2010, and 2014 GCs (0.25/0.32/0.53mm ID)

See sample photos of individual liners below ordering table.

Use the Drilled Uniliner® liner with the hole near the bottom for semivolatile analysis or when compounds of interest could be affected by a tailing solvent peak. Use the Drilled Uniliner® liner with the hole near the top for chlorinated pesticides analysis, aqueous injections, as well as for analysis in which the compounds of interest elute away from the solvent peak.
  Description Length OD Material Benefits/Uses Deactivation Packing ID qty. Cat.# Price     Wish
list
Cart 
 Uniliner®
  Uniliner w/Wool 95mm 5.0mm Borosilicate Glass trace, dirty, high MW active samples, high recovery & linearity Intermediate Polarity (IP) Deact. Wool 3.5mm ea.21713
  Uniliner w/Wool 95mm 5.0mm Borosilicate Glass trace, dirty, high MW active samples, high recovery & linearity Intermediate Polarity (IP) Deact. Wool 3.5mm 5-pk.21719
 Open-top Drilled Uniliner® (hole near top)
  Open-top Drilled Uniliner (hole near top) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Intermediate Polarity (IP)  3.5mm ea.21285
  Open-top Drilled Uniliner (hole near top) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Intermediate Polarity (IP)  3.5mm 5-pk.21286
  Open-top Drilled Uniliner (hole near top) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Siltek  3.5mm ea.21285-214.1
  Open-top Drilled Uniliner (hole near top) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Siltek  3.5mm 5-pk.21286-214.5
 Open-top Drilled Uniliner® (hole near bottom)
  Open-top Drilled Uniliner (hole near bottom) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Intermediate Polarity (IP)  3.5mm ea.21287
  Open-top Drilled Uniliner (hole near bottom) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Intermediate Polarity (IP)  3.5mm 5-pk.21288
  Open-top Drilled Uniliner (hole near bottom) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Siltek  3.5mm 5-pk.21288-214.5
 Gooseneck Drilled Uniliner® (hole near top)
  Gooseneck Drilled Uniliner (hole near top) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Intermediate Polarity (IP)  3.5mm ea.21289
  Gooseneck Drilled Uniliner (hole near top) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Intermediate Polarity (IP)  3.5mm 5-pk.21290
 Gooseneck Drilled Uniliner® (hole near bottom)
  Gooseneck Drilled Uniliner (hole near bottom) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Intermediate Polarity (IP)  3.5mm ea.21291
  Gooseneck Drilled Uniliner (hole near bottom) 95mm 5.0mm Borosilicate Glass trace, active samples, high recovery & linearity Intermediate Polarity (IP)  3.5mm 5-pk.21292
*Nominal ID at syringe needle expulsion point.
Note: liners are shown with column end at lower left.
Click thumbnails to see enlarged view.

21713
Uniliner® Liner 3.5mm x 5.0 x 95 for Shimadzu GCs IP Deact., w/Deact. Wool, ea

21285
Open Top Drilled Uniliner® Liner, Hole near Top, 3.5mm x 5.0 x 95 for Shimadzu GCs, IP Deact., ea

21287
Open Top Drilled Uniliner® Liner, Hole on Btm, 3.5mm x 5.0 x 95 for Shimadzu GCs, IP Deact., ea

21289
Gooseneck Drilled Uniliner® Liner, Hole near Top, 3.5mm x 5.0 x 95 for Shimadzu GCs IP Deact., ea

21291
Gooseneck Drilled Uniliner® Liner, Hole near Bottom, 3.5mm x 5.0 x 95 for Shimadzu GCs IP Deact., ea
   
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)