Welcome, Guest  -  Log In |  Register  |  Shopping Cart
< Environmental Reference Standards < Method 504.1 (Ethylene Dibromide/Dibromochloropropane)

USP 467 Singles



The United States Pharmacopeia (USP) general chapter <467> Residual Solvents is a widely used compendial method intended for identifying and quantifying residual solvents in drug substances, drug products, and excipients. In an attempt to better mirror the International Conference on Harmonization (ICH) guidelines, the USP has adopted a more comprehensive methodology in residual solvent testing--the current USP30/NF25. The ICH publishes a guideline (Q3C) listing the acceptable amounts of solvent residues that can be present. In the ICH guideline, residual solvents are summarized by class, according to their toxicity. Class 1 compounds are carcinogenic compounds that pose a risk to both the consumer and the environment. The use of these solvents is to be avoided, but if they are used, they must be tightly controlled. Class 2 compounds are nongenotoxic animal carcinogens, and concentrations of these compounds should be limited. Chromatographic analysis is needed for both the Class 1 and Class 2 residual solvents.
  Description CAS # Conc. in Solvent/Volume qty. Cat.# Price     Wish
list
Cart 
  acetonitrile 75-05-8 2.05mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36281
  benzene 71-43-2 10mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36282
  carbon tetrachloride 56-23-5 20mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36283
  chlorobenzene 108-90-7 1.8mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36284
  chloroform 67-66-3 0.3mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36285
  cyclohexane 110-82-7 19.4mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36286
  1,1-dichloroethene 75-35-4 40mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36287
  1,2-dichloroethane 107-06-2 25mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36288
  cis-1,2-dichloroethylene 156-59-2 4.67mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36289
  trans-1,2-dichloroethylene 156-60-5 4.67mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36290
  1,2-dimethoxyethane 173201-80-4 0.5mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36291
  N,N-dimethylacetamide 127-19-5 5.45mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36292
  N,N-dimethylformamide 68-12-2 4.4mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36293
  1,4-dioxane 123-91-1 1.9mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36294
  2-ethoxyethanol 110-80-5 0.8mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36295
  ethylbenzene 100-41-4 1.84mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36296
  ethylene glycol 3775-85-7 3.1mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36297
  formamide 75-12-7 1.1mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36298
  hexane 8031-34-3 1.45mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36299
  methanol 67-56-1 15mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36401
  2-methoxyethanol 109-86-4 0.25mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36402
  methylbutylketone 591-78-6 0.25mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36400
  methylcyclohexane 108-87-2 5.9mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36403
  methylene chloride (dichloromethane) 75-09-2 3mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36404
  N-methylpyrrolidone 872-50-4 2.65mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36405
  nitromethane 75-52-5 0.25mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36406
  pyridine 85404-20-2 1mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36407
  sulfolane 126-33-0 0.8mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36413
  tetrahydrofuran (THF) 109-99-9 3.6mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36408
  tetralin 119-64-2 0.5mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36409
  toluene 108-88-3 4.45mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36410
  1,1,1-trichloroethane 74552-83-3 50mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36411
  trichloroethene 79-01-6 0.4mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36412
  m-xylene 108-38-3 6.51mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36414
  o-xylene 95-47-6 0.97mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36415
  p-xylene 106-42-3 1.52mg/mL in dimethyl sulfoxide, 1mL/ampul ea.36416
Quantity Discounts
Order 3 or 4 of any one analytical reference material
product and receive a 10% discount! Order 5 or more
of any one analytical reference material product and
receive a 20% discount!

DMSO=dimethyl sulfoxide

     
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)