Dramatically increase lab efficiency!Double your cleaning capacity; holds twice as many cans as other models.
Save $500 for a limited time only.
Click here to download more technical information (2.5mb).To have a sales representative contact you,
click here.
- EPA Method TO-14A/15 compliant.
- Powerful pump can achieve 50mTorr in 30 minutes for 12 6L canisters.
- Custom-built trays for different canister sizes.
- One year limited warranty.
- Fully assembled and ready to use.
| Features | Benefits |
| Large capacity--holds 12 6L cans or 24 1L cans. |
Twice the capacity of other ovens for faster turnaround. |
| Embedded touch screen controller. |
No separate computer needed. |
| Adjustable oven control up to 110°C. |
Cleans canisters AND valves faster and more completely than heating bands. |
| 10 user defined methods. |
Each cleaning cycle parameter can be configured separately to minimize overall cycle time. |
| Edwards RV-8 vacuum pump. |
Cheaper to run and maintain than 2 pump alternatives. |
| Vacuum and pressure stainless steel cold traps. |
Keeps the system clean--no contamination from the pump or dirty canisters. |
| Automated system leak test triggers at 0.2psi. |
Ensures proper canister connections so required vacuum can be quickly achieved. |
| Dimensions: 44"H x 48"W x 27"D. |
Small footprint saves valuable lab space. |
| Oven cart available as option. |
Saves bench space and provides convenient mobility. |
|
TO-Clean from Wasson-ECE Instrumentation is a revolutionary canister cleaning system designed to take the guesswork out of canister cleaning. The system is fully automated, allowing the user to start a cleaning cycle and walk away. This is a high performance system that is easy to use and consistently produces excellent results.
Specifications:
TO-Clean Oven
Dimensions: 44"H x 48"W x 27"D
Weight: 525 lbs
Cart
Dimensions: 29"H x 27"W x 49"D
Weight: 486 lbs
Dewar
Weight: 5 lbs.
High capacity, fully automated, easy to use canister cleaning oven dramatically increases lab efficiency.
Prices, if listed below, reflect discounted amount.
Instruction Sheets:
Note: Ovens are built on demand, therefore, a ten week lead time is required on all orders. A limited cancellation and return policy applies to TO-Clean ovens; contact Restek Customer Service for details.
Simply place your order referencing the catalog number from the following table. Offer ends April 30, 2010. Discount cannot be combined with any other offers. Optional accessories not included in offer. Prices, if listed, reflect discounted amount.
Shipping: FedEx Ground, unless otherwise requested. Costs vary depending on ship-to location.