< Environmental Reference Standards < Method 535 (Chloroacetanilide Herbicide Degradates)

Ultra II® PFP Propyl 2.2µm, 3µm, & 5µm Columns (USP L43)



A pentafluorophenyl phase with a propyl spacer. Highly retentive for basic analytes. An excellent phase for separating nucleosides, nucleotides, purines, pyrimidines, and halogenated compounds.


particle size: 2.2µm, 3µm or 5µm, spherical
pore size: 100Å
carbon load: 11%
endcap: fully endcapped
pH range: 2.5 to 7.5
temperature limit: 80°C
1.9µm particle size coming soon!
  Description Length Pore Size (Å) Modification ID qty. Cat.# Price     Wish
list
Cart 
 2.2µm
  Ultra II PFP Propyl 30mm 100  2.1mm ea.9606832
  Ultra II PFP Propyl 50mm 100  2.1mm ea.9606852
  Ultra II PFP Propyl 100mm 100  2.1mm ea.9606812
  Ultra II PFP Propyl 30mm 100  3.0mm ea.9606833
  Ultra II PFP Propyl 50mm 100  3.0mm ea.9606853
  Ultra II PFP Propyl 100mm 100  3.0mm ea.9606813
 3µm
  Ultra II PFP Propyl 30mm 100  1.0mm ea.9606331
  Ultra II PFP Propyl 50mm 100  1.0mm ea.9606351
  Ultra II PFP Propyl 100mm 100  1.0mm ea.9606311
  Ultra II PFP Propyl 150mm 100  1.0mm ea.9606361
  Ultra II PFP Propyl 30mm 100  2.1mm ea.9606332
  Ultra II PFP Propyl 50mm 100  2.1mm ea.9606352
  Ultra II PFP Propyl 100mm 100  2.1mm ea.9606312
  Ultra II PFP Propyl 150mm 100  2.1mm ea.9606362
  Ultra II PFP Propyl 30mm 100  3.2mm ea.9606333
  Ultra II PFP Propyl 50mm 100  3.2mm ea.9606353
  Ultra II PFP Propyl 100mm 100  3.2mm ea.9606313
  Ultra II PFP Propyl 150mm 100  3.2mm ea.9606363
  Ultra II PFP Propyl 30mm 100  4.6mm ea.9606335
  Ultra II PFP Propyl 50mm 100  4.6mm ea.9606355
  Ultra II PFP Propyl 100mm 100  4.6mm ea.9606315
  Ultra II PFP Propyl 150mm 100  4.6mm ea.9606365
  Ultra II PFP Propyl 30mm 100 with Trident Inlet Fitting 2.1mm ea.9606332-700
  Ultra II PFP Propyl 50mm 100 with Trident Inlet Fitting 2.1mm ea.9606352-700
  Ultra II PFP Propyl 100mm 100 with Trident Inlet Fitting 2.1mm ea.9606312-700
  Ultra II PFP Propyl 150mm 100 with Trident Inlet Fitting 2.1mm ea.9606362-700
  Ultra II PFP Propyl 30mm 100 with Trident Inlet Fitting 3.2mm ea.9606333-700
  Ultra II PFP Propyl 50mm 100 with Trident Inlet Fitting 3.2mm ea.9606353-700
  Ultra II PFP Propyl 100mm 100 with Trident Inlet Fitting 3.2mm ea.9606313-700
  Ultra II PFP Propyl 150mm 100 with Trident Inlet Fitting 3.2mm ea.9606363-700
  Ultra II PFP Propyl 30mm 100 with Trident Inlet Fitting 4.6mm ea.9606335-700
  Ultra II PFP Propyl 50mm 100 with Trident Inlet Fitting 4.6mm ea.9606355-700
  Ultra II PFP Propyl 100mm 100 with Trident Inlet Fitting 4.6mm ea.9606315-700
  Ultra II PFP Propyl 150mm 100 with Trident Inlet Fitting 4.6mm ea.9606365-700
 5µm
  Ultra II PFP Propyl 30mm 100  1.0mm ea.9606531
  Ultra II PFP Propyl 50mm 100  1.0mm ea.9606551
  Ultra II PFP Propyl 100mm 100  1.0mm ea.9606511
  Ultra II PFP Propyl 150mm 100  1.0mm ea.9606561
  Ultra II PFP Propyl 200mm 100  1.0mm ea.9606521
  Ultra II PFP Propyl 250mm 100  1.0mm ea.9606571
  Ultra II PFP Propyl 30mm 100  2.1mm ea.9606532
  Ultra II PFP Propyl 50mm 100  2.1mm ea.9606552
  Ultra II PFP Propyl 100mm 100  2.1mm ea.9606512
  Ultra II PFP Propyl 150mm 100  2.1mm ea.9606562
  Ultra II PFP Propyl 200mm 100  2.1mm ea.9606522
  Ultra II PFP Propyl 250mm 100  2.1mm ea.9606572
  Ultra II PFP Propyl 30mm 100  3.2mm ea.9606533
  Ultra II PFP Propyl 50mm 100  3.2mm ea.9606553
  Ultra II PFP Propyl 100mm 100  3.2mm ea.9606513
  Ultra II PFP Propyl 150mm 100  3.2mm ea.9606563
  Ultra II PFP Propyl 200mm 100  3.2mm ea.9606523
  Ultra II PFP Propyl 250mm 100  3.2mm ea.9606573
  Ultra II PFP Propyl 30mm 100  4.6mm ea.9606535
  Ultra II PFP Propyl 50mm 100  4.6mm ea.9606555
  Ultra II PFP Propyl 100mm 100  4.6mm ea.9606515
  Ultra II PFP Propyl 150mm 100  4.6mm ea.9606565
  Ultra II PFP Propyl 200mm 100  4.6mm ea.9606525
  Ultra II PFP Propyl 250mm 100  4.6mm ea.9606575
  Ultra II PFP Propyl 30mm 100 with Trident Inlet Fitting 2.1mm ea.9606532-700
  Ultra II PFP Propyl 50mm 100 with Trident Inlet Fitting 2.1mm ea.9606552-700
  Ultra II PFP Propyl 100mm 100 with Trident Inlet Fitting 2.1mm ea.9606512-700
  Ultra II PFP Propyl 150mm 100 with Trident Inlet Fitting 2.1mm ea.9606562-700
  Ultra II PFP Propyl 200mm 100 with Trident Inlet Fitting 2.1mm ea.9606522-700
  Ultra II PFP Propyl 250mm 100 with Trident Inlet Fitting 2.1mm ea.9606572-700
  Ultra II PFP Propyl 30mm 100 with Trident Inlet Fitting 3.2mm ea.9606533-700
  Ultra II PFP Propyl 50mm 100 with Trident Inlet Fitting 3.2mm ea.9606553-700
  Ultra II PFP Propyl 100mm 100 with Trident Inlet Fitting 3.2mm ea.9606513-700
  Ultra II PFP Propyl 150mm 100 with Trident Inlet Fitting 3.2mm ea.9606563-700
  Ultra II PFP Propyl 200mm 100 with Trident Inlet Fitting 3.2mm ea.9606523-700
  Ultra II PFP Propyl 250mm 100 with Trident Inlet Fitting 3.2mm ea.9606573-700
  Ultra II PFP Propyl 30mm 100 with Trident Inlet Fitting 4.6mm ea.9606535-700
  Ultra II PFP Propyl 50mm 100 with Trident Inlet Fitting 4.6mm ea.9606555-700
  Ultra II PFP Propyl 100mm 100 with Trident Inlet Fitting 4.6mm ea.9606515-700
  Ultra II PFP Propyl 150mm 100 with Trident Inlet Fitting 4.6mm ea.9606565-700
  Ultra II PFP Propyl 200mm 100 with Trident Inlet Fitting 4.6mm ea.9606525-700
  Ultra II PFP Propyl 250mm 100 with Trident Inlet Fitting 4.6mm ea.9606575-700
     
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)