Purifier Modules: VICI® mat/sen® Gas-Specific

Dimensions: 21" x 1 1/2" (53.3 x 3.8 cm)


Performance for these purifiers is optimized by incorporating a multiple-bed format that progressively lowers concentrations of contaminants at each successive bed. VICI® Mat/Sen® purifiers are guaranteed to produce gases that are purer than 99.9999%, when supplied with gas of 99.995% purity, and are prepurged with the specified gas to speed conditioning. Purifier capacity is approximately four tanks of gas at 99.995% (50ppm) purity, and correspondingly longer for purer gases.


Please Note: We recommend using an indicating oxygen trap (e.g., cat.# 22029, pg. ) downstream from a VICI® Mat/Sen® purifier to continually ensure gas purity and indicate absolute change-out time.


Specifications:
Length: 21" (52.3cm)
Diameter: 1.5" (3.8cm)
Maximum Inlet Pressure: 1,000psi (6895kPa)
Maximum Recommended Flow: 500mL/min.
Pressure Drop from 120psi (827kPa) inlet at a flow of 0-500mL/min.: <0.20psi (1.4kPa)
Compression End Fittings: 1/8" or 1/4", stainless steel
Shipping Weight: 3.04 lb. (1,300 g)
  Description Fittings Max Pressure qty. Cat.# Price     Wish
list
Cart 
  Helium Purifier Module Compression Tube Fittings 1/4" 1000psi, 6895kPa ea.22600
  Helium Purifier Module Compression Tube Fittings 1/8" 1000psi, 6895kPa ea.22601
  Hydrogen Purifier Module Compression Tube Fittings 1/4" 1000psi, 6895kPa ea.22602
  Hydrogen Purifier Module Compression Tube Fittings 1/8" 1000psi, 6895kPa ea.22603
  Nitrogen Purifier Module* Compression Tube Fittings 1/4" 1000psi, 6895kPa ea.22604
  Nitrogen Purifier Module* Compression Tube Fittings 1/8" 1000psi, 6895kPa ea.22605
  Air Purifier Module Compression Tube Fittings 1/4" 1000psi, 6895kPa ea.22606
  Air Purifier Module Compression Tube Fittings 1/8" 1000psi, 6895kPa ea.22607
*Warning: Do not use with nitrogen containing more than 500ppm of oxygen. If the oxygen level in the stream exceeds 500ppm, use an air purifier.
We accept Visa, MasterCard and American Express   
Buy from an Authorized Restek Distributor to ensure top product quality, full warranty protection, and reliable technical support.
close

cat.#

 

*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)

Already signed up? Log In here.

e-mail:
password:

If you don't have a login, you can
Sign Up to create one instantly!


 
Please send: check all that apply
Product literature
Technical literature
Pricing
Distributor contact information
We will send the information to:
first name:
last name:
e-mail:
company:
city:
country: United States
areas of interest:

 
*First Name:
*Last Name:
*E-mail:
Company:
*City:
*Country:
 
Password:
Confirm Password:
Optional: what industries do you work in?
Environmental
Petrochemical
Pharmaceutical
Foods/Flavors/Fragrances
Clinical/Forensic/Toxicology
Chemicals
Other
(* = required fields)