![]() Raptor ARC-18 LC Columns (USP L1)
View Product Information |
![]() Raptor C18 LC Columns (USP L1)
View Product Information |
![]() Raptor Biphenyl LC Columns (USP L11)
View Product Information |
![]() Raptor FluoroPhenyl LC Columns (USP L43)
View Product Information |
![]() Raptor HILIC-Si LC Columns (USP L3)
View Product Information |
![]() Raptor Polar X LC Columns
Storage Conditions: When not in use, Raptor Polar X columns must be kept in 100% acetonitrile. If using a buffered mobile phase, first flush thoroughly with 50:50 water:acetonitrile, then fill with acetonitrile for storage. View Product Information |
![]() Force FluoroPhenyl LC Columns (USP L43)
View Product Information |
![]() Force C18 LC Columns (USP L1)
View Product Information |
![]() Force Biphenyl LC Columns (USP L11)
View Product Information |
![]() Ultra Biphenyl Columns (USP L11)Stationary Phase Category: phenyl (L11) Ligand Type: unique Biphenyl Particle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: 15% End-Cap: yes Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Pinnacle DB Biphenyl Columns (USP L11)Stationary Phase Category: phenyl (L11) Ligand Type: unique Biphenyl Particle: 1.9 µm, 3 µm, or 5 µm, spherical Pore Size: 140 Å Carbon Load: 8% End-Cap: yes Surface Area: 150 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Allure Acrylamide LC Column
View Product Information |
![]() PFAS Delay Column
View Product Information |
![]() Roc Silica HPLC Columns (USP L3)
View Product Information |
![]() Roc Cyano HPLC Columns (USP L10)
View Product Information |
![]() Roc Phenyl-Hexyl HPLC Columns (USP L11)
View Product Information |
![]() Roc C18 HPLC Columns (USP L1)
View Product Information |
![]() Roc C8 HPLC Columns (USP L7)
View Product Information |
![]() Pinnacle DB IBD UHPLC Columns (USP L68)Stationary Phase Category: polar-embedded alkyl (L68) Ligand Type: proprietary polar functional embedded alkyl Particle: 1.9 µm, spherical Pore Size: 140 Å Carbon Load: proprietary End-Cap: no Surface Area: 150 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Pinnacle DB PAH UHPLC ColumnsParticle: 1.9 µm, spherical Pore Size: 140 Å Carbon Load: proprietary End-Cap: no Surface Area: 150 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Pinnacle DB PFP Propyl Columns (USP L43)Stationary Phase Category: fluorophenyl propyl (L43) Ligand Type: pentafluorophenyl propyl Particle: 1.9 µm, 3 µm, or 5 µm, spherical Pore Size: 140 Å Carbon Load: 6% End-Cap: yes Surface Area: 150 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Viva Biphenyl Columns (USP L11)Stationary Phase Category: phenyl (L11) Ligand Type: Biphenyl Particle: 5 µm, spherical Pore Size: 300 Å Carbon Load: 7% End-Cap: yes Surface Area: 100 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Viva PFP Propyl Columns (USP L43)Stationary Phase Category: fluorophenyl propyl (L43) Ligand Type: pentafluorophenyl propyl Particle: 5 µm, spherical Pore Size: 300 Å Carbon Load: 5% End-Cap: yes Surface Area: 100 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Viva C4 Columns (USP L26)Stationary Phase Category: C4, butylsilane (L26) Ligand Type: monomeric C4 Particle: 5 µm, spherical Pore Size: 300 Å Carbon Load: 3.5% End-Cap: yes Surface Area: 100 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Viva C8 Columns (USP L7)Stationary Phase Category: C8, octylsilane (L7) Ligand Type: monomeric C8 Particle: 5 µm, spherical Pore Size: 300 Å Carbon Load: 5% End-Cap: yes Surface Area: 100 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Viva C18 Columns (USP L1)Stationary Phase Category: C18, octadecylsilane (L1) Ligand Type: monomeric C18 Particle: 3 µm or 5 µm, spherical Pore Size: 300 Å Carbon Load: 9% End-Cap: yes Surface Area: 100 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Viva Silica Columns (USP L3)Stationary Phase Category: bare silica (L3) Ligand Type: none Particle: 5 µm, spherical Pore Size: 300 Å Carbon Load: n/a End-Cap: n/a Surface Area: 100 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Pinnacle DB Silica Columns (USP L3)Stationary Phase Category: bare silica (L3) Ligand Type: none Particle: 1.9 µm, 3 µm, or 5 µm, spherical Pore Size: 140 Å Carbon Load: n/a End-Cap: n/a Surface Area: 150 m2/g pH Range: 2.5 to 8.0 Maximum Temperature: 80 °C View Product Information |
![]() Pinnacle DB Cyano Columns (USP L10)Stationary Phase Category: cyano (L10) Ligand Type: cyanopropylsilane Particle: 5 µm, spherical Pore Size: 140 Å Carbon Load: 4% End-Cap: yes Surface Area: 150 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Pinnacle DB C8 Columns (USP L7)Stationary Phase Category: C8, octylsilane (L7) Ligand Type: monomeric C8 Particle: 3 µm or 5 µm, spherical Pore Size: 140 Å Carbon Load: 6% End-Cap: yes Surface Area: 150 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Pinnacle DB C18 Columns (USP L1)Stationary Phase Category: C18, octadecylsilane (L1) Ligand Type: monomeric C18 Particle: 1.9 µm, 3 µm, or 5 µm, spherical Pore Size: 140 Å Carbon Load: 11% End-Cap: yes Surface Area: 150 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Raptor EtG/EtS LC Column
View Product Information |
![]() Ultra Aromax Columns (USP L11)Stationary Phase Category: phenyl (L11) Ligand Type: proprietary phenyl ligand Particle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: 17% End-Cap: yes Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Ultra PFP Propyl Columns (USP L43)Stationary Phase Category: fluorophenyl propyl (L43) Ligand Type: pentafluorophenyl propyl Particle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: 11% End-Cap: yes Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Pinnacle II PAH HPLC ColumnsParticle: 4 µm, spherical Pore Size: 110 Å Carbon Load: proprietary End-Cap: no Surface Area: 180 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Allure AK ColumnsParticle: 5 µm, spherical Pore Size: 60 Å Carbon Load: proprietary End-Cap: yes Surface Area: 450 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Ultra Quat ColumnsParticle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: proprietary Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Allure Organic Acids ColumnsParticle: 5 µm, spherical Pore Size: 60 Å Carbon Load: proprietary End-Cap: no Surface Area: 450 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Ultra Carbamate ColumnsParticle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: proprietary Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Ultra Silica Columns (USP L3)Stationary Phase Category: bare silica (L3) Ligand Type: none Particle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: n/a End-Cap: n/a Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Ultra IBD Columns (USP L68)Specialized Columns for Mixed Polar and Nonpolar Compounds. Stationary Phase Category: polar-embedded alkyl (L68) View Product Information |
![]() Ultra Cyano Columns (USP L10)Stationary Phase Category: cyano (L10) Ligand Type: cyanopropylsilane Particle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: 8% End-Cap: yes Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Ultra Aqueous C18 Columns (USP L1)Stationary Phase Category: modified C18 (L1) Ligand Type: proprietary polar modified and functionally bonded C18 Particle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: 15% End-Cap: no Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Ultra C18 Columns (USP L1)Excellent for a wide range of analyses. Stationary Phase Category: C18, octadecylsilane (L1) View Product Information |
![]() Ultra C8 Columns (USP L7)Excellent for a wide range of analyses. Stationary Phase Category: C8, octylsilane (L7) View Product Information |
![]() Ultra C4 Columns (USP L26)Stationary Phase Category: C4, butylsilane (L26) Ligand Type: monomeric C4 Particle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: 9% End-Cap: yes Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Ultra C1 Columns (USP L13)Stationary Phase Category: trimethylsilane (L13) Ligand Type: monomeric C1 Particle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: 5% End-Cap: yes Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Ultra Amino Columns (USP L8)Stationary Phase Category: amino (L8) Ligand Type: aminopropylsilane Particle: 3 µm or 5 µm, spherical Pore Size: 100 Å Carbon Load: 2% End-Cap: no Surface Area: 300 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |
![]() Allure Silica Columns (USP L3)Particle: 5 µm, spherical Highly retentive phase for normal phase separations. Very high surface area, Type B silica packing. Performing MOSH/MOAH analysis? Use cat.# 9160572 below. View Product Information |
![]() Pinnacle DB Aqueous C18 Columns (USP L1)Stationary Phase Category: modified C18 (L1) Ligand Type: proprietary polar modified and functionally bonded C18 Particle: 1.9 µm, 3 µm, or 5 µm, spherical Pore Size: 140 Å Carbon Load: 6% End-Cap: no Surface Area: 150 m2/g pH Range: 2.5 to 8 Maximum Temperature: 80 °C View Product Information |