Cannabis
Growing Analytical
Solutions for Cannabis Labs

  • Restek is an industry leader in new chromatography products and emerging applications.
  • We offer a full line of GC and LC supplies for fast, accurate, reliable cannabis analyses.
  • Extensive line of certified reference materials manufactured and QC tested in ISO-accredited labs.
  • Your continued success is our goal—we provide expert support for both startups and established labs.
Growing Analytical Solutions for Cannabis Labs

Whether you are an experienced potency testing chemist or a manager starting up a new lab, Restek has the products and expertise you need for successful cannabis analyses. We’ve been committed to this emerging industry from its humble beginnings through its recent years of rapid growth. During that time, we produced the first technical literature on potency testing in the business, and our experts continue to provide cutting-edge scientific support and a comprehensive line of products for new tests as they emerge. From analyzing potency and pesticides by LC to testing terpenes and residual solvents by GC, Restek offers the chromatography columns, accessories, and sample preparation supplies that you need for fast, accurate, reliable marijuana analyses. In addition, we have an extensive selection of cannabinoid-related certified reference materials (CRMs), manufactured and QC tested in ISO-accredited laboratories.

We’re proud to have helped cannabis labs establish sound analytical practices from the beginning, and we will continue to be there for you every step of the way as the testing landscape changes. Explore our products and resources and grow your cannabis testing business with analytical solutions from Restek!

Restek Expertise & Service

Our commitment to cannabis analysis extends beyond a trusted, well-rounded product line. If you're struggling with any part of your analyses, contact us—we’re here to help!

Restek Technical Service
1-814-353-1300, ext. 4 | Email

Columns

Rxi-35Sil MS Columns (fused silica)

midpolarity Crossbond phase

  • Special selectivity and excellent inertness for substituted polar compounds, such as drugs, pesticides, herbicides, PCBs, phenols, etc.
  • Provides superior separation for cannabinoids.
  • Very low-bleed phase for GC-MS analysis.
  • Extended temperature range: 50 °C up to 360 °C.

Rxi-624Sil MS Columns (fused silica)

midpolarity Crossbond phase

  • Low-bleed, high-thermal stability column—maximum temperatures up to 300–320 °C.
  • Inert—excellent peak shape for a wide range of compounds.
  • Selective—G43 phase highly selective for volatile organics and residual solvents, great choice for USP<467>.
  • Manufactured for column-to-column reproducibility—well suited for validated methods.

Rxi-5ms Columns (fused silica)

low-polarity phase; Crossbond diphenyl dimethyl polysiloxane

  • General-purpose columns for semivolatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners (e.g., Aroclor mixes), solvent impurities.
  • Most inert column on the market.
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • Temperature range: -60 °C to 330/350 °C.
  • Equivalent to USP G27 and G36 phases.

Rxi Guard/Retention Gap Columns (fused silica)

  • Extend column lifetime.
  • Excellent inertness—obtain lower detection limits for active compounds.
  • Sharper chromatographic peaks by utilizing retention gap technology.
  • Maximum temperature: 360 °C.

Raptor ARC-18 LC Columns (USP L1)

  • Ideal for high-throughput LC-MS/MS applications with minimal sample preparation.
  • Well-balanced retention profile for better detection and integration of large, multiclass analyte lists.
  • Sterically protected to endure low-pH mobile phases without sacrificing retention or peak quality.
  • Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.

Ultra Aqueous C18 Columns (USP L1)

Stationary Phase Category: modified C18 (L1)
Ligand Type: proprietary polar modified and functionally bonded C18
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 15%
End-Cap: no
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Reference Standards

Cannabichromene (CBC) Standard

Excluded from U.S. DEA Controlled Substances Act (CSA) regulatory controls—no customer permits or licensing required to purchase within the U.S.

Cannabidiol (CBD) Standard

Excluded from U.S. DEA Controlled Substances Act (CSA) regulatory controls—no customer permits or licensing required to purchase within the U.S.

Cannabidiolic Acid (CBDA) Standard

  • Pair with Restek's THC standards to analyze both neutrals and acids in cannabis products by LC.
  • A must for accurate quantification in cannabis potency testing and chemovar ID.
  • Prepared in acetonitrile, instead of methanol, to maintain stability and prevent methylation of carboxylic acid groups.
  • Restek has the products and expertise you need for cannabis analysis: www.restek.com/cannabis

Excluded from U.S. DEA Controlled Substances Act (CSA) regulatory controls—no customer permits or licensing required to purchase within the U.S.

Cannabidivarin (CBDV) Standard

  • Ideal for creating multipoint (5-point minimum suggested) calibration curves for LC analysis.
  • Pair with Restek's cannabinoid standards for more comprehensive analysis of cannabis products by LC.
  • A must for accurate quantification in cannabis potency testing and chemovar ID.
  • Verified composition and stability.
  • Prepared stock product eliminates the need for in-house standards preparation.
  • Restek has the products and expertise you need for cannabis analysis: www.restek.com/cannabis

Excluded from U.S. DEA Controlled Substances Act (CSA) regulatory controls—no customer permits or licensing required to purchase within the U.S.

Cannabidivarinic Acid (CBDVA) Reference Standard

  • Ideal for creating multipoint (5-point minimum suggested) calibration curves for LC analysis.
  • Pair with Restek's cannabinoid standards for a more-comprehensive analysis of cannabis products by LC.
  • A must for accurate quantification in cannabis potency testing and chemovar ID.
  • Verified composition and stability.
  • Prepared stock product eliminates the need for in-house standards preparation.
  • Restek has the products and expertise you need for cannabis analysis: www.restek.com/cannabis

Excluded from U.S. DEA Controlled Substances Act (CSA) regulatory controls—no customer permits or licensing required to purchase within the U.S.

Cannabigerol (CBG) Standard

Excluded from U.S. DEA Controlled Substances Act (CSA) regulatory controls—no customer permits or licensing required to purchase within the U.S.

Cannabigerolic Acid (CBGA) Standard

  • Pair with Restek's cannabinoid standards for more comprehensive analysis of cannabis and hemp products by LC.
  • A must for accurate quantification in cannabis potency testing and chemovar ID.
  • Verified composition and stability.
  • Prepared in acetonitrile, instead of methanol, to maintain stability and prevent methylation of carboxylic acid groups.
  • Restek has the products and expertise you need for cannabis analysis: www.restek.com/cannabis

Excluded from U.S. DEA Controlled Substances Act (CSA) regulatory controls—no customer permits or licensing required to purchase within the U.S.

Cannabicyclol (CBL) Standard

  • Ideal for creating multipoint (5-point minimum suggested) calibration curves for LC analysis.
  • Pair with Restek's cannabinoid standards for a more comprehensive analysis of cannabis products by LC.
  • A must for accurate quantification in cannabis testing and chemovar ID.
  • Verified composition and stability.
  • Prepared stock product eliminates the need for in-house standards preparation.
  • Restek has the products and expertise you need for cannabis analysis: www.restek.com/cannabis

Excluded from U.S. DEA Controlled Substances Act (CSA) regulatory controls—no customer permits or licensing required to purchase within the U.S.

Cannabinol (CBN) Standard

Excluded from U.S. DEA Controlled Substances Act (CSA) regulatory controls—no customer permits or licensing required to purchase within the U.S.

d8-Tetrahydrocannabinol (d8-THC) Standard

U.S. DEA-exempted formulation—no additional customer permits or licensing are required to purchase within the U.S.

d9-Tetrahydrocannabinol (d9-THC) Standard

U.S. DEA-exempted formulation—no additional customer permits or licensing are required to purchase within the U.S.

d9-Tetrahydrocannabinolic Acid A (THCA-A) Standard

U.S. DEA-exempted formulation—no additional customer permits or licensing are required to purchase within the U.S.

Tetrahydrocannabivarin (THCV) Standard

  • A must for accurate quantification in cannabis potency testing and chemovar ID.
  • Verified composition and stability.
  • Restek has the products and expertise you need for cannabis analysis: www.restek.com/cannabis

U.S. DEA-exempted formulation—no additional customer permits or licensing are required to purchase within the U.S.

Cannabinoids Standard (3 components)

U.S. DEA-exempted formulation—no additional customer permits or licensing are required to purchase within the U.S.

Cannabis Terpenes Standard #1 (19 components)

  • Formulated to contain the major terpenes analyzed by cannabis labs.
  • Prepared in two separate multicomponent mixes to maximize stability. (View mix 2.)
  • Comprehensive blends minimize time spent preparing standards for marijuana analysis.
  • High concentration (2,500 µg/mL) solutions provide value and maximize flexibility.

Cannabis Terpenes Standard #2 (2 components)

  • Formulated to contain the major terpenes analyzed by cannabis labs.
  • Prepared in two separate multicomponent mixes to maximize stability. (View mix 1.)
  • Comprehensive blends minimize time spent preparing standards for marijuana analysis.
  • High concentration (2,500 µg/mL) solutions provide value and maximize flexibility.

Aflatoxins (B1, B2, G1, G2) Standard (4 components)

Ideal for mycotoxin analyses in cannabis and food testing labs.

Ochratoxin A Standard

Ideal for mycotoxin analyses in cannabis and food testing labs.

Residual Solvents #1 (20 components)

  • Designed for cannabis labs testing residual solvents at different threshold limits by headspace GC.
  • Contains 20 commonly analyzed solvents in one convenient solution.
  • Verified composition and stability.
  • In stock and available for immediate shipment.

Residual Solvents Reference Standards

Analyzing pharmaceuticals or other matrices for residual solvents? We have reference standards to help you satisfy USP <467>, European Pharmacopoeia/ICH, and other method requirements.

California Pesticide Standards (6 separate mixes)

  • Meet specific cannabis analysis needs of California set forth by the Bureau of Cannabis Control for regulated category I and II residual pesticide reporting—and of states with similar regulations/programs.
  • Ideal for creating multipoint (5-point minimum suggested) calibration curves for GC- and LC-MS/MS.
  • Verified composition and stability.
  • 66 compounds in 6 x 1 mL ampuls at 100 μg/mL.
  • Prepared stock product eliminates the need for in-house standards preparation.
  • Restek has the products and expertise you need for cannabis analysis: www.restek.com/cannabis

Oregon Pesticide Standards (6 separate mixes)

  • Meet specific cannabis pesticide residue analysis needs of Oregon – and states with similar pesticide residue regulations/programs.
  • Verified composition and stability.
  • 59 compounds in 6 x 1 mL ampules at 600 µg/mL – resulting in a convenient 100 µg/mL solution when blended immediately before use.
  • Prepared stock product eliminates the need for in-house standards preparation.

LC Multiresidue Pesticide Kit

  • Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.
  • Full kit contains 204 compounds of interest, covering many LC-determined pesticides listed by government agencies; individual ampuls also sold separately.

GC Multiresidue Pesticide Kit

  • Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.
  • Comprehensive 203-compound kit covers food safety lists by the FDA, USDA, and other global governmental agencies; individual ampuls also sold separately.

QuEChERS Performance Standards Kit

  • Designed for use in all QuEChERS methods for pesticides in fruits and vegetables, including the original unbuffered method, AOAC 2007.01, and EN 15662.
  • Kit contains organochlorine, organonitrogen, organophosphorus, and carbamate pesticides commonly used on fruits and vegetables.
  • Volatile, polar, active, base-sensitive, and nonvolatile compounds are included to allow comprehensive evaluation of QuEChERS extraction and cleanup efficiencies, and optimization of GC and LC instrumental conditions.
  • Ideal for initial method evaluations and ongoing method performance validations.
  • Analytes are divided into three ampuls based on compatibility for maximum stability and shelf life.*
  • Precise formulations improve data quality and operational efficiency; spend more time running samples and less time sourcing and preparing standards.
  • Quantitatively analyzed to confirm the composition and stability of each mixture.

*When combining compounds with different functionalities, chemical stability can be an issue. The analytes in this kit are separated into three mixes to ensure maximum long-term storage stability. For analysis, a fresh working standard should be prepared by combining the three kit mixes in a 1:1:1 ratio to prepare a 100 µg/mL working standard solution. Once blended, Restek does not recommend storing working standards or subsequent dilutions for future use.

Contains 1 mL each of these mixtures.
31153: QuEChERS Performance Standard A
31154: QuEChERS Performance Standard B
31155: QuEChERS Performance Standard C

Sample Handling

Q-sep QuEChERS Extraction Salts

  • Free-flowing salts transfer easily and completely.
  • Easy-open packets eliminate the need for a second empty tube for salt transfer.
  • Convenient slim packets fit perfectly into tubes to prevent spills.
  • Ready-to-use tubes, no glassware required.
  • Pre-weighed, ultra-pure extraction salts.
  • Ideal for original unbuffered, AOAC (2007.01), and European (EN 15662) QuEChERS methods.

Q-sep QuEChERS dSPE Tubes for Extract Cleanup

Fast, Simple Sample Prep for Multiresidue Pesticide Analysis

  • Packaged in foil subpacks of 10 for enhanced protection and storage stability.
  • Ready-to-use tubes, no glassware required.
  • Pre-weighed, ultra-pure sorbents.
  • Support original unbuffered, AOAC (2007.01), European (EN 15662), and mini-multiresidue QuEChERS methods.

Pesticide Residue Cleanup SPE Cartridges

  • Convenient, multiple adsorbent beds in a single cartridge.
  • For use in multiresidue pesticide analysis to remove matrix interferences.
  • Excellent for cleanup of dietary supplement extracts.

Resprep C18 SPE Cartridges (Reverse-Phase mode)

  • High-quality, silica-based hydrophobic adsorbents.
  • Used to extract hydrophobic analytes from polar matrices, such as water (e.g., pesticides from water).
  • Stable over the pH range (2 – 8).
  • All cartridges are end-capped.

Thomson SINGLE StEP Standard Filter Vials

  • Recommended for samples containing less than 10% solid particulates.
  • Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers.
  • Minimize sample loss by eliminating multiple transfers.
  • Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon.
  • Preslit PTFE/silicone caps help eliminate broken autosampler needles and cored septa.
  • Rugged polypropylene vial houses insert with 450 μL loading capacity and low dead volume (120 μL).
  • Fit most standard 12 x 32 mm autosamplers, including UHPLC instruments.

EXP Direct Connect Holder

  • Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connections—no tools needed.
  • Patented titanium hybrid ferrules can be installed repeatedly without compromising high-pressure seal.
  • Auto-adjusting design provides ZDV (zero dead volume) connection to any 10-32 female port.
  • EXP direct connect holder requires separate guard column cartridges; available from Restek in 2.1, 3.0, and 4.6 mm.
  • Pair with EXP hand-tight fitting (cat.# 25937–25938) for tool-free installation.

Supplies & Accessories

GC Accessories

Full line of GC consumables, lab tools to make your life easier, and replacement parts for all major instrument manufacturers.

LC Accessories

Quality replacement parts, tools, and accessories for liquid chromatography.

2.0 mL, 8 mm Autosampler Vial Convenience Kits

  • Vials packaged in a clear-lid tray.
  • Preassembled caps with septa packaged separately in a plastic bag.
  • Black polypropylene open-hole caps and 8 mm red PTFE/silicone septa, 0.065".

Hamilton Manual Microliter Syringes

  • Economical.
  • Available with cemented needles (N/F) or removable needles (RN/R).
  • Each syringe plunger and barrel assembly is manufactured as one working unit; components are not interchangeable or individually replaceable.

Merlin MicroShot Injector

ChromaBLOGraphy

posted Fri, Feb 26, 2021
Glyphosate and… Cannabis?
posted Thu, Feb 18, 2021
Cannabis Potency Testing & Calibration Curves
posted Thu, Feb 11, 2021
Analyzing THC Concentrates? Look for Isomers!
posted Mon, Apr 27, 2015
Residual Solvents in Cannabis – to MS or not to MS?
posted Wed, Jan 14, 2015
CBDV and THCV on the Rxi-35Sil MS GC Column with Other Cannabinoids
posted Fri, Jan 16, 2015
Internal Standard versus External Standard Quantification in Medical Cannabis Potency Analysis with GC-FID
posted Fri, Jun 14, 2013
The separation problem with CBC and CBD in GC analysis of medical cannabis with 5% phenyl-type columns.
posted Sun, Feb 17, 2013
Don’t overestimate cannabidiol during medical cannabis potency determinations with gas chromatography. Use stationary phase selectivity for accuracy and hydrogen for fast analysis.
posted Sun, May 20, 2012
Screening for Bifenazate (Floramite) in Medical Marijuana Using QuEChERS and GC-FID – Is it Possible?
posted Fri, Apr 20, 2012
Medical Marijuana Musings
posted Wed, Aug 03, 2011
Medical Marijuana Solvent Extraction Efficiency – Potency Determinations with GC-FID
posted Sat, Jul 30, 2011
The Impact of a Dirty Marijuana Extract on Pesticide Recoveries from a Splitless GC Inlet
posted Fri, Jul 29, 2011
Thiabendazole – Planar Pesticide Loss to Graphitized Carbon Black during Dispersive Solid Phase Extraction Cleanup for QuEChERS
posted Sat, Jul 02, 2011
The Bard Hits the Bong?
posted Sun, May 22, 2011
High Quality Analysis of Pesticides in Marijuana using QuEChERS, Cartridge SPE Cleanup, and GCxGC-TOFMS
posted Wed, Apr 20, 2011
First QuEChERS Extraction of Marijuana with GCxGC-TOFMS Analysis, dudes…
View all our cannabis blogs...

Literature

Foods, Flavors & Fragrances

Analysis of Pesticides, Mycotoxins, and Cannabinoids in Cannabis Gummies

In this application note, we present an easy, effective workflow for the analysis pesticides, mycotoxins, and cannabinoids in cannabis gummies. This method streamlines testing by allowing quantitation of multiple analyte classes from a single sample extract.

Foods, Flavors & Fragrances

Quantitative LC-UV Method for CBD in Topicals with Simplified Extraction of Lotions, Balms, and Creams

This LC-UV method for CBD in topicals uses a single sample extraction procedure for lotions, balms, and creams paired with a simple isocratic analysis to produce a fast, efficient workflow for high-throughput labs.

Foods, Flavors & Fragrances

Featured Application: Cannabinoid Profiles on Raptor ARC-18 - High Throughput Analysis of Cannabinoids by LC-UV

This simple, isocratic LC-UV analysis of cannabinoids provides complete resolution of 16 cannabinoids, allowing accurate quantitative potency and profile data to be reported. All compounds are separated to baseline in a fast, 9-minute analysis, making this method suitable for high-throughput cannabis testing labs.

Clinical, Forensic & Toxicology

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

The analysis of synthetic cannabinoids and their metabolites can be a difficult and challenging task. Keeping up with the ever-growing list of synthetic cannabinoids that illicit drugmakers produce further complicates the analysis. As shown here, the retention and selectivity of the Raptor Biphenyl column allows new drugs to be added to an existing method, providing labs with an important vehicle for improving efficiency and productivity.

Foods, Flavors & Fragrances

High-Quality Analysis of Pesticides in Cannabis Using QuEChERS, Cartridge SPE Cleanup, and GCxGC-TOFMS

As medical marijuana is more frequently prescribed, patient safety must be ensured. Pesticide residue testing is an important part of assuring safe product is dispensed, but analysis can be extremely challenging due to matrix complexity. The use of QuEChERS, cartridge SPE cleanup, and GCxGC-TOFMS as presented here, produces high-quality quantitative data for this difficult analysis.

Foods, Flavors & Fragrances

Analysis of Pesticides and Mycotoxins in Cannabis Brownies

Government regulations in California require the cannabis industry to test edible products for an extensive list of pesticides and mycotoxins. Here, an effective workflow for this complex analysis was developed in brownies, and optimization strategies are detailed in order to provide a starting point for similar matrices. Both LC-MS/MS and GC-MS/MS were employed and excellent results for LOQ, linearity, accuracy, and precision were attained for all the target compounds.

PDF Document

Accurately Quantify 380 Pesticides Using LC-MS/MS and GC-MS/MS

Stop spending your time and money developing LC-MS/MS or GC-MS/MS multiresidue pesticide methods and mixing reference standards when you could be running samples. Restek’s expert formulations chemists and chromatographers have already done the work for you—with guaranteed accuracy and at a lower cost. (PDF - 0MB)

GC Chromatograms

General Interest
General Interest
General Interest
General Interest
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
General Interest
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances
Foods, Flavors & Fragrances

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us