USP Phase and Support Cross-Reference Chart

USP Phase and Support Cross-Reference Chart

Table I:  Cross-reference a non-Restek phase or support to an equivalent Restek phase or support.

LIQUID PHASES

USP Nomenclature

Restek Equivalent

Notes

Dimethyl polysiloxane oil

G1

Rtx-1, Rt-2100, OV-101

 

100% Dimethylpolysiloxane gum, polydimethylsiloxane, or polymethylsiloxane

G2

Rtx-1, OV-1

 

50% Phenyl-50% methylpolysiloxane

G3

Rt-2550, OV-17

 

DEGS-PS

G4

Rt-DEGS

Diethylene glycol succinate polyester

3-Cyanopropylpolysiloxane

G5

Rt-2340

 

Trifluoropropylmethylpolysiloxane

G6

Rt-2401

 

50% 3-Cyanopropyl-50% phenylmethylsilicone

G7

Rt-2300

 

80% Bis (3-cyanopropyl)- 20% phenylpolysiloxane

G8

Rtx-2330

 

Methylvinylpolysiloxane

G9

Rtx-1

 

Bis(2-ethylhexyl)sebacate polyester

G11

Bis(2-ethylhexyl)sebacate polyester

 

Phenyldiethanolamine succinate polyester

G12

Phenyldiethanolamine succinate polyester

 

D-Sorbitol

G13

Sorbitol

Same properties without binding.

Polyethylene glycol (avg. mol. wt. of 950 to 1050) or PEG 1000

G14

Carbowax 1000 (g/mole)

 

Polyethylene glycol (avg. mol. wt. of 3000 to 3700)

G15

Carbowax 4000 (g/mole)

 

Macrogol 20000 or PEG 20M

G16

Carbowax 20M (g/mole), Stabilwax

Polyethylene glycol compound (avg. mol. wt. about 15,000). A high molecular weight compound of polyethylene glycol with a diepoxide linker.

75% Phenyl-25% methylpolysiloxane

G17

OV-25

 

Polyalkylene glycol

G18

UCON LB 550X

NOT AVAILABLE/CONTACT TECHNICAL SUPPORT FOR SUGGESTION

25% Phenyl-25% cyanopropyl-50% methylsilicone or p/p poli (cyano-propyl)(methyl)(phenyl)(methyl) siloxane

G19

OV-225

 

Polyethylene glycol (avg. mol. wt. of 380 to 420)

G20

Carbowax 400 (g/mole)

 

Neopentyl glycol succinate

G21

Neopentyl glycol succinate

 

Bis(2-ethylhexyl) phthalate

G22

Bis(2-ethylhexyl) phthalate

 

Polyethylene glycol adipate, ethylene glycol adipate

G23

EGA

 

Diisodecyl phthalate

G24

Diisodecyl phthalate

 

Polyethylene glycol compound TPA. A high molecular weight compound of a polyethylene glycol and a diepoxide that is esterified with terephthalic acid.

G25

Carbowax 20M TPA (g/mole)

 

25% 2-Cyanoethyl-75% methylpolysiloxane

G26

Rt-XE-60

 

5% Phenyl-95% methylpolysiloxane

G27

Rtx-5, SE-52

 

25% Phenyl-75% methylpolysiloxane

G28

DC 550

 

3,3’-thiodipropionitrile

G29

TDPN

 

Tetraethylene glycol dimethyl ether

G30

Tetraethylene glycol dimethyl ether

 

CO880 or nonylphenoxypoly(ethyleneoxy)ethanol (avg. ethyleneoxy chain length is 30); nonoxynol 30.

G31

IGEPAL-CO 880

 

20% Phenylmethyl-80% dimethylpolysiloxane

G32

OV-7

 

Diethylene glycol succinate polyester stabilized with phosphoric acid

G34

Rt-DEGS PS

 

AT-1000 or a high molecular weight compound of a polyethylene glycol and a diepoxide that is esterified with nitroterephthalic acid.

G35

Rt-1000

 

1% vinyl-5% phenylmethylpolysiloxane

G36

Rtx-5, SE-54

 

Phase G1 containing a small percentage of a tailing inhibitor

G38

Rt-2100/ 0.1% Carbowax 1500 (g/mole)

 

Polyethylene glycol (avg. mol. wt. about 1500)

G39

Carbowax 1500/1540 (g/mole)

Macrogol 1500 or PEG 1500

SOLID SUPPORTS

USP

Restek Equivalent

Notes

Siliceous earth flux calcined, acid washed and water washed until neutral

S1A

Silcoport-W, DiatoSorb-WAW, DiatoSorb-WHP

 

Siliceous earth, treated as S1A and both acid and base washed

S1AB

N/A

Contact technical support for suggestions.

A support prepared from crushed firebrick and calcined or burned with a clay binder above 900 °C with subsequent acid wash. It may be silanized.

S1C

Chromosorb PAW, Chromosorb PAW DMDCS

 

A support prepared from crushed firebrick and calcined or burned with a clay binder above 900 °C, not acid washed. It may be silanized.

S1D

Chromosorb PNAW

 

Untreated siliceous earth

S1NS

DiatoSorb-WNAW

 

Styrene-divinylbenzene co-polymer having a nominal surface area of less than 50 m2 per gram and an average pore size of 0.3 to 0.4 μm

S2

Chromosorb 101

 

Ethyl vinylbenzene-divinylbenzene co-polymer having a nominal surface area of less than 500-600 m2 per gram and an average pore size of 0.0075 μm

S3

HayeSep Q

 

Styrene-divinylbenzene copolymer with aromatic -O and -N groups having a nominal surface area of 400 to 600 m2/g and an average pore diameter of 0.0076 μm

S4

HayeSep R

 

High molecular weight tetrafluoroethylene polymer 40 to 60 mesh

S5

Chromosorb T 40/60

 

Styrene-divinylbenzene co-polymer having a nominal surface area of less than 250 - 300 m2 per gram and an average pore size of 0.0091 μm

S6

HayeSep P

 

Graphitized carbon having a nominal surface of 12 m2 per gram

S7

CarboBlack C

 

Copolymer of 4-vinylpyridine styrene-divinylbenzene

S8

HayeSep S

 

Porous polymer based on 2,6-diphenyl-p-phenylene oxide

S9

Tenax TA

 

Highly cross-linked co-polymer of acrylonitrile and divinylbenzene

S10

HayeSep C

 

Graphitized carbon having a nominal surface of 100 m2 per gram modified with small amounts of petrolatum and polyethylene glycol compound

S11

CarboBlack B 80/120 3% Rt-1500

 

Graphitized carbon having a nominal surface area of 100 m2 per g

S12

CarboBlack B

 
 

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us