share:

Reference Standards: Other

Looking for a Specific Compound?

Enter a compound name, synonym, or CAS # below.

Products

Silylation Derivatization Reagents

  • Replace active hydrogen, reducing polarity and making the compounds more volatile.
  • Increase stability of derivatives.

View Product Information

Alkylation Derivatization Reagents

  • Add alkyl groups to functional hydrogens (H).
  • Decrease polarity on compounds containing acidic hydrogens, i.e., phenols, carboxylic acids.
  • Form an ester.

View Product Information

Acylation Derivatization Reagents

  • Most commonly used for electron capture detection.
  • React with alcohols, amines, and phenols.
  • Frequently used for drugs of abuse confirmation.

View Product Information

Weathered Diesel Fuel #2 Kit

Contains 1 mL each of these 5000 µg/mL in methylene chloride mixtures.
31233: Diesel Fuel #2 Standard
31234: Diesel Fuel #2 Standard: 25% Weathered
31235: Diesel Fuel #2 Standard: 50% Weathered
31236: Diesel Fuel #2 Standard: 75% Weathered

View Product Information

Weathered Kerosene Kit

Contains 1 mL each of these mixtures.
31229: Kerosene Standard
31230: Kerosene Standard: 25% Weathered
31231: Kerosene Standard: 50% Weathered
31232: Kerosene Standard: 75% Weathered

View Product Information

Weathered Gasoline Kit #2

Contains 1 mL each of these mixtures.
30096: Unleaded Gasoline Standard
30097: Unleaded Gasoline Standard: 25% Weathered
30098: Unleaded Gasoline Standard: 50% Weathered
30099: Unleaded Gasoline Standard: 75% Weathered
30436: Unleaded Gasoline Standard: 99% Weathered

View Product Information

Mineral Spirits

There are four general types of mineral spirits, classified according to boiling point range (BPR):
  • Type I (Stoddard solvent), BPR 149–182 °C
  • Type II (high flash point), BPR 177–196 °C
  • Type III (odorless), BPR 149–196 °C
  • Type IV (low dry point), BPR 149–174 °C

    This standard is manufactured using the Type 1 mineral spirit.

    Note: Cat.#s 31260 and 31261 are produced with CAS# 64475-85-0, a Type 1 Mineral Spirit containing the proper ratio of n-alkanes (higher proportion) and isoparaffins/cycloalkanes (lower proportion). Lots produced prior to March 2017 contained CAS# 8030-30-6, a C10-C13 isoparaffins odorless Mineral Spirit with >98% isoparaffins (branched alkanes/aromatics) and minimal n-alkanes.

View Product Information

Diesel Fuel #2 (ASTM Class 5 Accelerant)

Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

View Product Information

Kerosene (ASTM Class 4 Accelerant)

Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

View Product Information

Unleaded Gasoline (ASTM Class 2 Accelerant)

Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

View Product Information

Stoddard Solvent Standard

We offer this certified reference material for those who need to calibrate Stoddard solvent separately. This standard is dissolved in methanol for analysis by either direct injection or purge and trap.

View Product Information

Restek Domestic Customer Service

Subject

Message

Your Email

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us