Underground Storage Tank Monitoring (UST)

Reference Standards: Underground Storage Tank Monitoring (UST)

Looking for a Specific Compound?

Enter a compound name, synonym, or CAS # below.

Products

Qualitative Retention Time Index Standard (27 components)

  • Appropriate for a wide range of retention index systems.
  • Certified reference material (CRM) verified to be stable and accurate.
  • Qualitatively analyzed to confirm composition; certificate available for each CRM lot.

View Product Information

Mineral Spirits

There are four general types of mineral spirits, classified according to boiling point range (BPR):
  • Type I (Stoddard solvent), BPR 149–182 °C
  • Type II (high flash point), BPR 177–196 °C
  • Type III (odorless), BPR 149–196 °C
  • Type IV (low dry point), BPR 149–174 °C

    This standard is manufactured using the Type 1 mineral spirit.

    Note: Cat.#s 31260 and 31261 are produced with CAS# 64475-85-0, a Type 1 Mineral Spirit containing the proper ratio of n-alkanes (higher proportion) and isoparaffins/cycloalkanes (lower proportion). Lots produced prior to March 2017 contained CAS# 8030-30-6, a C10-C13 isoparaffins odorless Mineral Spirit with >98% isoparaffins (branched alkanes/aromatics) and minimal n-alkanes.

View Product Information

MA VPH Matrix Spike Mix with Surrogate Rev. 1.1 (July 2004) (16 components)

  • For current Massachusetts VPH method: surrogate included.
  • Matrix spike mix at 50µg/mL, per updated method.

View Product Information

MA VPH Standard with Surrogate Rev. 1.1 (July 2004) (16 components)

  • Standard for current Massachusetts VPH method: surrogate included.
  • More analyses per ampulstandard with surrogate is 10,000µg/mL.

View Product Information

CA WIP VOA Standard (11 components)

For monitoring samples suspected of gasoline contamination, Los Angeles County requires laboratories to calibrate and report these compounds.

View Product Information

Certified Aromatics in Gasoline (16 components)

  • Confirm unleaded gasoline TPH, BTEX, and aromatics in a single analysis.
  • Certificate of Analysis includes concentration of TPH, and certified concentrations of BTEX and individual aromatics.
  • Complete data pack available.

View Product Information

Stoddard Solvent Standard

We offer this certified reference material for those who need to calibrate Stoddard solvent separately. This standard is dissolved in methanol for analysis by either direct injection or purge and trap.

View Product Information

Fuel Oil Degradation Mix (4 components)

Subsurface degradation of fuel oil spills can be estimated by examining the ratios of C17/pristane and C18/phytane.1 To assist in identifying these four compounds from the complex fuel oil analysis, we offer a product that contains these compounds for retention time determination.

View Product Information

Diesel Fuel #2 Standard

Prepared from a single-source (one-refinery) product.

View Product Information

Kerosene Standard

Prepared from a single-source (one-refinery) product.

View Product Information

Unleaded Gasoline Standard

Prepared from a single-source (one-refinery) product.

View Product Information

Hydraulic Oil Standard

  • For total petroleum hydrocarbon pattern recognition of hydraulic oil.
  • High concentration50,000 µg/mL in methylene chloride.

View Product Information

Creosote Oil Standard

Creosote oil is a coal tar derived distillate.

  • For total petroleum hydrocarbon pattern recognition of creosote oil.
  • High concentration50,000 µg/mL in methylene chloride.

View Product Information

Aviation Gas Standard

100-octane, low-lead fuel used in piston-type aircraft.

View Product Information

Fuel Oil #6 Standard

A high-viscosity residual type of heavy fuel oil requiring preheating to 104–127 °C. This material is also known as residual fuel oil (RFO) or Bunker C.

View Product Information

Fuel Oil #4 Standard

Fuel oil #4 is typically used in limited applications in which the fuel cannot be preheated prior to burning. The fuel is a blend of distillate (fuel oil #2) and residual (fuel oil #6).

View Product Information

Used Motor Oil Composite Standard

  • Prepared from an equal-volume blend from five gasoline-powered vehicles (belonging to Restek employees). After blending, a precisely weighed amount of the composite is added to a volumetric flask to produce the standard.
  • Motor oil standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

View Product Information

Motor Oil Composite Standard

  • Prepared from an equal-volume blend of 5W30, 10W30, 10W40, and 20W50 motor oils. After blending, a precisely weighed amount of the composite is added to a volumetric flask to produce the standard.
  • Motor oil standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

View Product Information

Kerosene Composite Standard

  • Kerosene composite standards are comprised of three separate sources blended in equal portions.
  • Kerosene standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

View Product Information

Diesel Fuel #2 Composite Standard

  • Diesel Fuel composite standards are comprised of three separate sources blended in equal portions.
  • Diesel Fuel standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

View Product Information

Unleaded Gasoline Composite Standard

  • Unleaded gasoline composite standards are comprised of three separate sources each of 87, 89, and 93 octane blended in equal portions.
  • Gasoline standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

    Note: BTEX content of catalog numbers 30081, 30205, and 30206 is not measured. Certified BTEX gasoline standards are available as catalog numbers 30237 and 30485.

View Product Information

TNRCC 1005 Retention Time Markers Mix (4 components)

  • Easily determine the retention time window for each boiling point range.
  • Prepared in n-pentane according to EPA requirements.

View Product Information

Massachusetts APH Mix (26 components)

Our high-quality air monitoring gas calibration standards are provided by Spectra/Linde and Airgas (formerly Scott/Air Liquide gas)meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.

To view compatible regulators, select your standard below and see Restek Recommends.

View Product Information

BTEX Gas Mix (6 components)

Our high-quality air monitoring gas calibration standards are provided by Spectra/Linde and Airgas (formerly Scott/Air Liquide gas)meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.

To view compatible regulators, select your standard below and see Restek Recommends.

View Product Information

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us