share:

Reference Standards: Food Safety

Looking for a Specific Compound?

Enter a compound name, synonym, or CAS # below.

Products

Residual Solvents #1 (20 components)

  • Designed for cannabis labs testing residual solvents at different threshold limits by headspace GC.
  • Contains 20 commonly analyzed solvents in one convenient solution.
  • Verified composition and stability.
  • In stock and available for immediate shipment.

View Product Information

LC Multiresidue Pesticide Kit

  • Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.
  • Full kit contains 204 compounds of interest, covering many LC-determined pesticides listed by government agencies; individual ampuls also sold separately.

View Product Information

QuEChERS Performance Standards Kit

  • Designed for use in all QuEChERS methods for pesticides in fruits and vegetables, including the original unbuffered method, AOAC 2007.01, and EN 15662.
  • Kit contains organochlorine, organonitrogen, organophosphorus, and carbamate pesticides commonly used on fruits and vegetables.
  • Volatile, polar, active, base-sensitive, and nonvolatile compounds are included to allow comprehensive evaluation of QuEChERS extraction and cleanup efficiencies, and optimization of GC and LC instrumental conditions.
  • Ideal for initial method evaluations and ongoing method performance validations.
  • Analytes are divided into three ampuls based on compatibility for maximum stability and shelf life.*
  • Precise formulations improve data quality and operational efficiency; spend more time running samples and less time sourcing and preparing standards.
  • Quantitatively analyzed to confirm the composition and stability of each mixture.

    *When combining compounds with different functionalities, chemical stability can be an issue. The analytes in this kit are separated into three mixes to ensure maximum long-term storage stability. For analysis, a fresh working standard should be prepared by combining the three kit mixes in a 1:1:1 ratio to prepare a 100 µg/mL working standard solution. Once blended, Restek does not recommend storing working standards or subsequent dilutions for future use.

    Contains 1 mL each of these mixtures.
    31153: QuEChERS Performance Standard A
    31154: QuEChERS Performance Standard B
    31155: QuEChERS Performance Standard C

View Product Information

Pyrethrins Standard

Isomeric in nature, the pyrethrins neat material contains the following isomers: cinerin I and II, jasmolin I and II, and pyrethrin I and II. Isomer ratios for each lot are given in elution order on the certificate.

View Product Information

GC Multiresidue Pesticide Kit

  • Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.
  • Comprehensive 203-compound kit covers food safety lists by the FDA, USDA, and other global governmental agencies; individual ampuls also sold separately.

View Product Information

Oregon Pesticide Standards (6 separate mixes)

  • Meet specific cannabis pesticide residue analysis needs of Oregon – and states with similar pesticide residue regulations/programs.
  • Verified composition and stability.
  • 59 compounds in 6 x 1 mL ampules at 600 µg/mL – resulting in a convenient 100 µg/mL solution when blended immediately before use.
  • Prepared stock product eliminates the need for in-house standards preparation.

    If you formerly ordered these standards as customs, review compound lists before ordering — to improve stability, some formulations were changed slightly.

View Product Information

MOSH/MOAH Retention Time Standard (10 components)

  • Developed specifically for using LC coupled with GC-FID to accurately determine hydrocarbons found in mineral oils, which can migrate from processing equipment and packaging into food.
  • This 10-component mix contains both mineral oil saturated hydrocarbon (MOSH) and mineral oil aromatic hydrocarbon (MOAH) markers that are used to accurately identify GC retention time limits for integration.

View Product Information

EU 15+1 PAH Standard (16 components)

  • Formulated to contain the 16 major European Food Safety Authority (EFSA) PAH compounds.
  • High concentration (100 μg/mL) solution provides value and flexibility. Dilute as needed for fortification and calibration mixes.
  • Low-volatility toluene solvent provides longer shelf life, which helps ensure more accurate results.
  • Broad solvent miscibility—compatible with acetonitrile, the QuEChERS solvent.

View Product Information

GC Multiresidue Pesticide Standard #9 (8 components)

Organophosphorus Compounds

Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

View Product Information

GC Multiresidue Pesticide Standard #8 (24 components)

Organophosphorus Compounds

Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

View Product Information

GC Multiresidue Pesticide Standard #7 (10 components)

Herbicide Methyl Esters

Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

View Product Information

GC Multiresidue Pesticide Standard #6 (18 components)

Synthetic Pyrethroid Compounds

Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

View Product Information

GC Multiresidue Pesticide Standard #5 (34 components)

Organonitrogen Compounds

Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

View Product Information

GC Multiresidue Pesticide Standard #4 (28 components)

Organonitrogen Compounds

Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

View Product Information

GC Multiresidue Pesticide Standard #3 (25 components)

Organonitrogen Compounds

Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

View Product Information

GC Multiresidue Pesticide Standard #2 (40 components)

Organochlorine Compounds

Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

View Product Information

GC Multiresidue Pesticide Standard #1 (16 components)

Organophosphorus Compounds

Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

View Product Information

QuEChERS Performance Standard C (17 components)

  • Designed for use in all QuEChERS methods for pesticides in fruits and vegetables, including the original unbuffered method, AOAC 2007.01, and EN15662.
  • Ideal for initial method evaluations and ongoing method performance validations.
  • Optimized blend of chemically compatible analytes for maximum stability and shelf life.
  • Precise formulation improves data quality and operational efficiency; spend more time running samples and less time sourcing and preparing standards.
  • Quantitatively analyzed to confirm the composition and stability of each mixture.

View Product Information

QuEChERS Performance Standard B (7 components)

  • Designed for use in all QuEChERS methods for pesticides in fruits and vegetables, including the original unbuffered method, AOAC 2007.01, and EN15662.
  • Ideal for initial method evaluations and ongoing method performance validations.
  • Optimized blend of chemically compatible analytes for maximum stability and shelf life.
  • Precise formulation improves data quality and operational efficiency; spend more time running samples and less time sourcing and preparing standards.
  • Quantitatively analyzed to confirm the composition and stability of each mixture.

View Product Information

QuEChERS Performance Standard A (16 components)

  • Designed for use in all QuEChERS methods for pesticides in fruits and vegetables, including the original unbuffered method, AOAC 2007.01, and EN15662.
  • Ideal for initial method evaluations and ongoing method performance validations.
  • Optimized blend of chemically compatible analytes for maximum stability and shelf life.
  • Precise formulation improves data quality and operational efficiency; spend more time running samples and less time sourcing and preparing standards.
  • Quantitatively analyzed to confirm the composition and stability of each mixture.

View Product Information

LC Multiresidue Pesticide Standard #10 (Carbendazim)

Carbamate/Uron Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

LC Multiresidue Pesticide Standard #9 (7 components)

Carbamate/Uron Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

LC Multiresidue Pesticide Standard #8 (Hydramethylnon)

Organonitrogen Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

LC Multiresidue Pesticide Standard #7 (7 components)

Organonitrogen Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

LC Multiresidue Pesticide Standard #6 (28 components)

Organonitrogen Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

LC Multiresidue Pesticide Standard #5 (30 components)

Organonitrogen Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

LC Multiresidue Pesticide Standard #4 (63 components)

Organonitrogen Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

LC Multiresidue Pesticide Standard #3 (38 components)

Carbamate/Uron Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

LC Multiresidue Pesticide Standard #2 (16 components)

Carbamate/Uron Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

LC Multiresidue Pesticide Standard #1 (13 components)

Organophosphorus Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

View Product Information

MOSH/MOAH Standard (9 components)

  • Developed specifically for using LC coupled with GC-FID to accurately determine hydrocarbons found in mineral oils, which can migrate from processing equipment and packaging into food.
  • This 9-component mix contains noninterfering internal standards as well as both mineral oil saturated hydrocarbon (MOSH) and mineral oil aromatic hydrocarbon (MOAH) markers that are used to correctly cut LC fractions.

View Product Information

Labeled Pesticide Residue Internal Standards for Food Analysis

  • Isotopically labeled to provide the best approach for pesticide residue quantification.
  • Multiple options let you choose internal and surrogate standards that will mitigate matrix effects.
  • Economically priced and compatible with both LC-MS and GC-MS applications; even helpful for optimizing LC-MS/MS system performance.
  • Restek is your complete supplier for world-class food safety analysis: pesticide reference standard mixes and internal/surrogate standards, GC and LC columns, QuEChERS, and more!

View Product Information

EFSA PAH4 Standard (4 components)

  • European Food Safety Authority (EFSA) PAH4 compounds prepared in toluene solvent.
  • High 1,000 µg/mL concentrationdilute as needed to economically prepare custom mixes.
  • Low volatilitylonger shelf life and more accurate results.
  • High miscibilitycompatible with QuEChERS solvents.

View Product Information

AOAC QuEChERS QC Spike Mix (27 components)

  • Ready to use for generating test mixes, calibration standards, and spiking experiments.
  • Reliable standards produced according to specifications defined in AOAC Official Method 2007.01.
  • Cost-effective QuEChERS standards can be used without dilutions for greater lab efficiency.

View Product Information

AOAC QuEChERS Triphenylphosphate Solution

  • Ready to use for generating test mixes, calibration standards, and spiking experiments.
  • Reliable standards produced according to specifications defined in AOAC Official Method 2007.01.
  • Cost-effective QuEChERS standards can be used without dilutions for greater lab efficiency.

View Product Information

AOAC QuEChERS IS Solution (2 components)

  • Ready to use for generating test mixes, calibration standards, and spiking experiments.
  • Reliable standards produced according to specifications defined in AOAC Official Method 2007.01.
  • Cost-effective QuEChERS standards can be used without dilutions for greater lab efficiency.

View Product Information

QuEChERS Single-Component Reference Standards

Ready to use for QuEChERS extractionsno dilutions necessary.

View Product Information

QuEChERS Quality Control Standards for GC-MS Analysis

Ready to use for QuEChERS extractionsno dilutions necessary.

View Product Information

QuEChERS Internal Standard Mix for LC-MS/MS Analysis (Nicarbazin)

Ready to use for QuEChERS extractionsno dilutions necessary.

View Product Information

QuEChERS Internal Standard Mix for GC-MS Analysis (6 components)

Ready to use for QuEChERS extractionsno dilutions necessary.

View Product Information

FAPAS Series 9 OP Pesticide Mix 1 (10 components)

Equal concentration of all compounds. Suitable for GC-FPD, GC-NPD, and GC-MS analysis.

View Product Information

FAPAS Series 5 OC Pesticide Mix 2 (19 components)

Varied concentrations. Suitable for GC-ECD analysis.

View Product Information

Minnesota Ag List 1 Pesticide Kit

Contains 1 mL each of these mixtures.
32406: Minnesota Ag List Pesticides Mix A
32407: Minnesota Ag List Pesticides Mix B

View Product Information

ASTM D6042-96 Calibration Mix (7 components)

This mixture contains the common antioxidants and slips listed in ASTM D6042-96, along with BHT.

View Product Information

531.2 Carbamate Pesticide Calibration Mixture (11 components)

  • Complete set of materials for N-methylcarbamoyloximes and N-methylcarbamates.
  • New mix satisfies latest update of EPA Method 531.2.
  • Formulated in acetonitrile for stability and convenience for LC analysis.

View Product Information

Herbicide Mix #2

Derivatized Form

Herbicide Mix #2

Free Acid Form