Reference Standards: Test Mixes

Looking for a Specific Compound?

Enter a compound name, synonym, or CAS # below.

Products

LC Passivation Solution

Used to passivate your LC system before your first analysis if you:

(a) are analyzing phosphorylated compounds or other polar molecules known to chelate or interact with metal ions in your LC (e.g., glyphosate);

and also

(b) have stainless steel in your instrument flow path;

and/or also

(c) your LC column hardware is showing activity towards phosphorylated compounds or other polar molecules known to chelate.


View Product Information

SPME Performance Test Mix (2 components)

  • Essential mix for establishing the performance of SPME fibers and SPME Arrows.
  • Verified composition and stability.

View Product Information

Dimethyldichlorosilane (DMDCS) Deactivating Agent

  • Easy deactivation of liners and other glass surfaces.
  • Convenient—25 mL bottle deactivates 60 inlet liners.
  • Tested to ensure consistent quality and effectiveness.

View Product Information

LC OQ Standards Kit

This kit contains one ampul of each of the following items (unless otherwise specified):
30012: LC OQ gradient standard, 1 mL
31053: LC OQ wavelength accuracy standard, 5 mL
31068: LC OQ linearity kit, six 1 mL ampuls (contents detailed below)*

*Components of the LC linearity kit (cat.# 31068) are not available for individual sale.


View Product Information

Silylation Derivatization Reagents

  • Replace active hydrogen, reducing polarity and making the compounds more volatile.
  • Increase stability of derivatives.

View Product Information

Alkylation Derivatization Reagents

  • Add alkyl groups to functional hydrogens (H).
  • Decrease polarity on compounds containing acidic hydrogens, i.e., phenols, carboxylic acids.
  • Form an ester.

View Product Information

Acylation Derivatization Reagents

  • Most commonly used for electron capture detection.
  • React with alcohols, amines, and phenols.
  • Frequently used for drugs of abuse confirmation.

View Product Information

LC Performance Test Mix (5 components)

  • Highly effective for characterizing LC column parameters.
  • Simple, easy, reliable approach to quality control (QC) evaluations or column classification.
  • Monitor column performance over time.

View Product Information

Carbohydrate LC Performance Check Mix (5 components)

  • For simple sugar analysis by LC with refractive index/light scattering detection.
  • Use with a silica column with amino functionality, as recommended by AOAC International.
  • Use as a calibration standard for AACC Method 80-04.
  • Offered dry for enhanced stability.

View Product Information

LC OQ Linearity Test Mix Kit

Contains 1 mL each of these mixtures.
31804: Caffeine (caffeine at 5 µg/mL in water)
31803: Caffeine (caffeine at 25 µg/mL in water)
31802: Caffeine (caffeine at 125 µg/mL in water)
31801: Caffeine (caffeine at 250 µg/mL in water)
31800: Caffeine (caffeine at 500 µg/mL in water)

View Product Information

LC Reversed Phase Test Mix #1 (4 components)

Routine analysis using this mix can assist in determining the need to perform column and/or system maintenance.

View Product Information

LC Normal Phase Test Mix #1 (4 components)

Routine analysis using this mix can assist in determining the need to perform column and/or system maintenance.

View Product Information

Amine Column Test Mix (GC) (8 components)

For Stabilwax-DB, Rtx-5 Amine, Rtx-35 Amine, and Rtx-Volatile Amine columns.

View Product Information

Grob Test Mix (Capillary GC) (12 components)

For use with temperature-programmed conditions.

View Product Information

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us